Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 36 min ago
PreprintCC BY 4.0arXiv

Spin-polarized tunneling from a Kondo insulator: equilibrium surface magnetism versus magneto-electric response in SmB6

Abstract

We theoretically analyze the spin-polarized tunneling between SmB6 tip and the bicollinear antiferromagnet Fe1+xTe. The emergence of magnetic contrast in tunneling requires time-reversal symmetry breaking on the surface of the tip. The magnetic contrast part of the tunneling conductance then has two contributions: the first one originates from the magnetic moment due to the equilibrium long-range order on the surface, while the other is governed by the magnetic moment induced by the electric field of the junction through the surface magneto-electric effect. We show that the ratio of the equilibrium moment to the response extracted near zero bias equals, up to the sign, twice the bias at which the contrast changes sign, independently of the relative strength of the two mechanisms, so that this ratio itself does not measure the strength of the magneto-electric effect. We find that within the experimental energy window |eV|≲10~meV the {bias-dependent} field-induced contribution is at most a few percent of the equilibrium one, and the two become comparable only at biases of order $100$~meV or higher. The ratio of the field-induced to the equilibrium contribution is inversely proportional to the distance between the tip and the substrate.

Related

  1. Tunneling spectroscopy of topological insulator Josephson junctions
    Jakob Schluck, Ella Nikodem, Anton Montag +4
    Science AdvancesPeer-reviewedCC BYFull textCondensed matterSci. Adv.CrossrefEurope PMCEurope PMC+1
  2. Topological Chiral Superconductivity from Doping Correlated Charge Transfer Insulator with Orbital Magnetism
    Wen Sun, Yuan Yang, Shou-Shu Gong +1
    arXivPreprintarXiv licenceFull textCondensed matterarXiv
  3. Odd-parity surface magnetism in a Kondo insulator
    Maxim Dzero, Brian M. Andersen
    arXivPreprintCC BY 4.0Full textCondensed matterarXiv
  4. Imaging the topological sign of a Dirac mass with spin-polarized tunneling
    Payman Kazemikhah, Ruolun Zhang, Byunghoon Kim +5
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationCondensed matterarXiv
  5. Direct observation of a spin-polarized surface Dirac gap in the antiferromagnetic topological insulator NdBi
    Yuto Fukushima, Hiroyuki S. Suzuki, Masayuki Ochi +15
    arXivPreprintCC BY 4.0Full textCondensed matterarXiv
BibTeX
@misc{dzero2026spinpolarized,
  title = {{Spin-polarized tunneling from a Kondo insulator: equilibrium surface magnetism versus magneto-electric response in SmB$_6$}},
  author = {Maxim Dzero and Brian M. Andersen},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.36886},
  eprint = {2610.36886},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.36886},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Spin-polarized tunneling from a Kondo insulator: equilibrium surface magnetism versus magneto-electric response in SmB_6
AU  - Maxim Dzero
AU  - Brian M. Andersen
PY  - 2026
DA  - 2026/10/27
PB  - arXiv
DO  - 10.48550/arxiv.2610.36886
UR  - https://arxiv.org/abs/2610.36886
AB  - We theoretically analyze the spin-polarized tunneling between SmB_6 tip and the bicollinear antiferromagnet Fe_1+xTe. The emergence of magnetic contrast in tunneling requires time-reversal symmetry breaking on the surface of the tip. The magnetic contrast part of the tunneling conductance then has two contributions: the first one originates from the magnetic moment due to the equilibrium long-range order on the surface, while the other is governed by the magnetic moment induced by the electric field of the junction through the surface magneto-electric effect. We show that the ratio of the equilibrium moment to the response extracted near zero bias equals, up to the sign, twice the bias at which the contrast changes sign, independently of the relative strength of the two mechanisms, so that this ratio itself does not measure the strength of the magneto-electric effect. We find that within the experimental energy window |eV|≲10~meV the {bias-dependent} field-induced contribution is at most a few percent of the equilibrium one, and the two become comparable only at biases of order $100$~meV or higher. The ratio of the field-induced to the equilibrium contribution is inversely proportional to the distance between the tip and the substrate.
ER  -