Determining the Optimal Left Ventricular Outflow Tract Assessment for Aortic Valve Area Calculation in Tricuspid and Bicuspid Valves Using 3D Echocardiography.
- 1Princess Alexandra Hospital, Brisbane, Australia.
- 2Medical School, University of Queensland, Brisbane, Australia.
- 3Mater Hospital Brisbane, Brisbane, Australia.
Abstract
Purpose
The weakest link in aortic valve area (AVA) calculation by the continuity equation (AVACE) during 2D transthoracic echocardiography (TTE) is underestimation of the left ventricular outflow tract (LVOT) diameter (LVOTD). Proposed solutions were founded on 2D imaging, geometrical assumptions, and validated exclusively in tricuspid aortic valves (TAV). There is little evidence to guide imaging optimization in bicuspid valves (BAV) despite recognized differences in their LVOT morphologies. We aimed to determine the optimal approach for LVOT assessment in TAVs and BAVs using 3D TTE.Methods
Patients with 2D and 3D TTE assessments of the LVOT and aortic valve were identified. LVOTDs were measured on 2D images while multiplanar reconstructions of the 3D datasets were performed to obtain LVOT area (LVOTA) and circumference (LVOTC). AVACE was calculated using the different 2D/3D LVOT measurements and compared with AVA by 3D planimetry (AVA3D).Results
100 TAVs (mean age 46.2 ± 17.5years, 36% females) and 100 BAVs (34.9 ± 14.5years, 50% females) were included. In comparison to AVA3D, calculation of AVACE in TAVs was best using 3D LVOTA (Intraclass correlation coefficient (ICC)>0.9; P < 0.001), while LVOTC resulted in overestimation of the AVA due to greater LVOT ellipticity. In BAVs, both 3D LVOTA and LVOTC resulted in ICCs>0.9 (P < 0.001). 2D LVOTDs resulted in underestimation of the AVA with a smaller error if measured at the annulus.Conclusions
3D TTE provides optimal assessments of the LVOT for AVACE calculations. 3D-based LVOTAs are suitable for both TAVs and BAVs. If 3D is unavailable, 2D LVOTD measurements should be performed at the annulus.
Related
- Baseline right ventricular assessment and outcomes after transcatheter tricuspid valve repair.
- Curriculum-Based Deep Learning for Automated Segmental Left Ventricular Hypertrophy Classification Using Short-Axis Echocardiography
- Transthoracic echocardiography vs. cardiac magnetic resonance imaging for the diagnosis of left ventricular thrombus: an updated systematic review and diagnostic accuracy meta-analysis
- Prognostic Value of Right Ventricular–Pulmonary Artery Coupling in Mitral Valve Surgery and Impact of Concomitant Tricuspid Valve Repair
- Acute right ventricular response to transcatheter tricuspid valve replacement
BibTeX
@article{frampton2026determining,
title = {{Determining the Optimal Left Ventricular Outflow Tract Assessment for Aortic Valve Area Calculation in Tricuspid and Bicuspid Valves Using 3D Echocardiography.}},
author = {Alex Frampton and Adrian Chong and Mark Dooris and Sudhir Wahi and William Y S Wang},
journal = {Echocardiography (Mount Kisco, N.Y.)},
year = {2026},
month = nov,
doi = {10.1111/echo.70684},
url = {https://europepmc.org/article/MED/43080180},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - Determining the Optimal Left Ventricular Outflow Tract Assessment for Aortic Valve Area Calculation in Tricuspid and Bicuspid Valves Using 3D Echocardiography.
AU - Alex Frampton
AU - Adrian Chong
AU - Mark Dooris
AU - Sudhir Wahi
AU - William Y S Wang
PY - 2026
DA - 2026/11/01
JO - Echocardiography (Mount Kisco, N.Y.)
DO - 10.1111/echo.70684
UR - https://europepmc.org/article/MED/43080180
AB - Purpose The weakest link in aortic valve area (AVA) calculation by the continuity equation (AVACE) during 2D transthoracic echocardiography (TTE) is underestimation of the left ventricular outflow tract (LVOT) diameter (LVOTD). Proposed solutions were founded on 2D imaging, geometrical assumptions, and validated exclusively in tricuspid aortic valves (TAV). There is little evidence to guide imaging optimization in bicuspid valves (BAV) despite recognized differences in their LVOT morphologies. We aimed to determine the optimal approach for LVOT assessment in TAVs and BAVs using 3D TTE.Methods Patients with 2D and 3D TTE assessments of the LVOT and aortic valve were identified. LVOTDs were measured on 2D images while multiplanar reconstructions of the 3D datasets were performed to obtain LVOT area (LVOTA) and circumference (LVOTC). AVACE was calculated using the different 2D/3D LVOT measurements and compared with AVA by 3D planimetry (AVA3D).Results 100 TAVs (mean age 46.2 ± 17.5years, 36% females) and 100 BAVs (34.9 ± 14.5years, 50% females) were included. In comparison to AVA3D, calculation of AVACE in TAVs was best using 3D LVOTA (Intraclass correlation coefficient (ICC)>0.9; P < 0.001), while LVOTC resulted in overestimation of the AVA due to greater LVOT ellipticity. In BAVs, both 3D LVOTA and LVOTC resulted in ICCs>0.9 (P < 0.001). 2D LVOTDs resulted in underestimation of the AVA with a smaller error if measured at the annulus.Conclusions 3D TTE provides optimal assessments of the LVOT for AVACE calculations. 3D-based LVOTAs are suitable for both TAVs and BAVs. If 3D is unavailable, 2D LVOTD measurements should be performed at the annulus.
SN - 0742-2822
SN - 1540-8175
ER -