Real-Time Single-Pixel Imaging via Exploiting Temporal Mixing: A Unified Calibration and Composite Readout Framework
Abstract
In high-speed optical measurements and computational imaging such as in single-pixel imaging temporal mixing arising from the mismatch between modulation and the electro-optical acquisition chain is conventionally treated as an unmitigated distortion that corrupts measurement orthogonality, breaks compressive sensing priors, fundamentally limits imaging speed, and induces catastrophic reconstruction failure. Here, we establish a transferable, unified calibration and composite-readout framework for single-pixel imaging that systematically repurposes temporal memory from a readout limitation into a powerful measurement resource. Beyond achieving robust high-fidelity recovery, this engineered approach enables cost effective, lower bandwidth configurations to consistently deliver superior image quality compared to higher bandwidth reference setups across diverse operating conditions turning a historical hardware bottleneck into an active imaging advantage. Specifically, target scenes are reconstructed directly from mixed observations without the need to recover individual pattern projections, thereby significantly advancing high-speed and video-rate single-pixel imaging capabilities. Crucially, the transferability of our framework allows calibration routines established on one hardware platform (such as digital micromirror device-based setups) to be readily transferred across different optical systems (such as rotating coding disks), paving the way for calibrated temporal memory as a versatile and generalized measurement paradigm for broader computational imaging.
Related
- Imaging-based visible light positioning exploiting yin-yang-yao-pattern fiducial markers on edge-lit LED panel luminaires
- Scene-based semi-supervised algorithm for self-calibration of polarization imaging systems
- High resolution X-ray phase contrast imaging for non-destructive testing of composite materials (2022)
- Real-Time Atomic-Resolution Electron Phase Imaging without Probe Calibration via Ptychography-Supervised Learning
- The James Webb Space Telescope Absolute Flux Calibration. VI. Near-infrared Camera Imaging and Coronagraphy
BibTeX
@misc{li2026realtime,
title = {{Real-Time Single-Pixel Imaging via Exploiting Temporal Mixing: A Unified Calibration and Composite Readout Framework}},
author = {Jing-Sen Li and En-Rui Zhang and Kan-Xu Jia and Yi-Zhu Zhang and Qian-Qian Bao and Shao-Ying Meng and Xi-Hao Chen},
howpublished = {arXiv},
year = {2026},
month = nov,
doi = {10.48550/arxiv.2611.25700},
eprint = {2611.25700},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2611.25700},
}
RIS
TY - UNPB
TI - Real-Time Single-Pixel Imaging via Exploiting Temporal Mixing: A Unified Calibration and Composite Readout Framework
AU - Jing-Sen Li
AU - En-Rui Zhang
AU - Kan-Xu Jia
AU - Yi-Zhu Zhang
AU - Qian-Qian Bao
AU - Shao-Ying Meng
AU - Xi-Hao Chen
PY - 2026
DA - 2026/11/19
PB - arXiv
DO - 10.48550/arxiv.2611.25700
UR - https://arxiv.org/abs/2611.25700
AB - In high-speed optical measurements and computational imaging such as in single-pixel imaging temporal mixing arising from the mismatch between modulation and the electro-optical acquisition chain is conventionally treated as an unmitigated distortion that corrupts measurement orthogonality, breaks compressive sensing priors, fundamentally limits imaging speed, and induces catastrophic reconstruction failure. Here, we establish a transferable, unified calibration and composite-readout framework for single-pixel imaging that systematically repurposes temporal memory from a readout limitation into a powerful measurement resource. Beyond achieving robust high-fidelity recovery, this engineered approach enables cost effective, lower bandwidth configurations to consistently deliver superior image quality compared to higher bandwidth reference setups across diverse operating conditions turning a historical hardware bottleneck into an active imaging advantage. Specifically, target scenes are reconstructed directly from mixed observations without the need to recover individual pattern projections, thereby significantly advancing high-speed and video-rate single-pixel imaging capabilities. Crucially, the transferability of our framework allows calibration routines established on one hardware platform (such as digital micromirror device-based setups) to be readily transferred across different optical systems (such as rotating coding disks), paving the way for calibrated temporal memory as a versatile and generalized measurement paradigm for broader computational imaging.
ER -