A dual CEST-fluorescent reporter enables cross-validated tracking of hematopoietic engraftment in deep bone marrow.
4 affiliations
- 1Faculty of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa, Israel.
- 2Biomedical Core Facility, Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel.
- 3Biomedical Engineering Faculty, Tel Aviv University, Tel Aviv, Israel.
- 4Chemical Engineering and Radiology, Michigan State University, East Lansing, USA.
Abstract
Reporter gene imaging can enable detection of engineered cells in vivo, but tracking hematopoietic engraftment within deep bone marrow (BM) remains challenging. We addressed this challenge by developing a dual CEST-MRI and fluorescent reporter system for cross-validated detection of reporter-positive donor-derived hematopoietic cells and their progeny in BM, with fluorescence-based assessment of HSPC-enriched compartments.Methods
A lentiviral dual-reporter cassette co-expressing the red fluorescent protein mScarlet-I (mScarlet) and the CEST-MRI reporter SuperCESTide (SC) via a T2A linker was evaluated in CT26 colon carcinoma cells in vitro and in a bilateral flank tumor model with contralateral reporter-transduced and non-transduced tumors in BALB/c mice (n = 6 tumors per group). In vivo optical imaging, CEST-MRI, ex vivo optical imaging, fluorescence microscopy, and histology were used for validation. The platform was then applied to primary murine hematopoietic lineage-negative (Lin⁻) cells and Lin⁻Sca-1⁺c-Kit⁺ (LSKs), with reporter expression analyzed by fluorescence microscopy and flow cytometry. Reporter-transduced Lin⁻ cells were transplanted into C57BL/6J mice after half-body irradiation, and engraftment was assessed 8 weeks later by whole-body fluorescence imaging, femoral CEST-MRI, intravital calvarial microscopy, ex vivo confocal microscopy, optical imaging, and flow cytometry. Femoral CEST-MRI was compared among non-irradiated controls, irradiated recipients transplanted with non-reporter-transduced Lin⁻ cells, and irradiated recipients transplanted with mScarlet-SC reporter-transduced Lin⁻ cells.Results
The dual mScarlet-SuperCESTide reporter showed efficient expression in CT26 cells and generated detectable red fluorescence and increased CEST-MRI contrast in reporter-positive tumors compared with contralateral non-transduced controls. Ex vivo optical imaging and histology confirmed reporter expression in tumor tissue. In murine BM-derived Lin⁻ cells, reporter expression was detected by fluorescence microscopy and flow cytometry, supporting feasibility in sensitive hematopoietic populations. Following transplantation, reporter-transduced Lin⁻ cells were detected eight weeks after engraftment using fluorescence imaging and femoral CEST-MRI. The recipients with reporter-transduced Lin⁻ cells showed increased femoral CEST contrast associated with the reporter compared with both irradiated recipients transplanted with non-transduced Lin⁻ cells and non-irradiated BM controls. Additionally, intravital microscopy visualized mScarlet⁺ cells within the BM niches of the calvarium. Ex vivo confocal microscopy and optical imaging confirmed reporter retention in BM, and flow cytometry confirmed mScarlet signal within Lin⁻ and LSK hematopoietic compartments in reporter-transduced recipients compared with non-transduced controls.Conclusion
We developed a dual CEST-fluorescent reporter platform that enables cross-validated imaging of reporter-transduced hematopoietic cells in deep BM. By integrating noninvasive CEST-MRI with fluorescence-based cellular validation, this feasibility study establishes a preclinical framework for cross-validated, noninvasive assessment of engineered hematopoietic cell localization and persistence in vivo and supports future evaluation of the platform for serial imaging.
Related
- 1121 Insights from orthotopic tumor engraftment in humanized mice
- Mast cells may promote myeloma engraftment in the NSG-hIL6 patient derived xenograft model
- Beta-cell replacement for type 1 diabetes: integrating cell products, engraftment and immune protection.
- In vivo engraftment of vascular structures in 3D-engineered artificial tissues vascularized by cord blood- or peripheral blood-derived endothelial colony-forming cells
- Long‐term persistence of Sox10CreERT2‐driven reporter labeling in enteric glia of mice under physiological and inflammatory conditions
BibTeX
@article{alter2026dual,
title = {{A dual CEST-fluorescent reporter enables cross-validated tracking of hematopoietic engraftment in deep bone marrow.}},
author = {Tehila Alter and Narmeen Haj and Doaa Ali-Naffaa and Maya Rom and Ramez Daniel and Galit Saar and Assaf A Gilad and Katrien Vandoorne},
journal = {Theranostics},
year = {2026},
month = sep,
doi = {10.7150/thno.140697},
url = {https://europepmc.org/article/MED/42909934},
note = {CC BY},
}
RIS
TY - JOUR
TI - A dual CEST-fluorescent reporter enables cross-validated tracking of hematopoietic engraftment in deep bone marrow.
AU - Tehila Alter
AU - Narmeen Haj
AU - Doaa Ali-Naffaa
AU - Maya Rom
AU - Ramez Daniel
AU - Galit Saar
AU - Assaf A Gilad
AU - Katrien Vandoorne
PY - 2026
DA - 2026/09/24
JO - Theranostics
DO - 10.7150/thno.140697
UR - https://europepmc.org/article/MED/42909934
AB - Reporter gene imaging can enable detection of engineered cells in vivo, but tracking hematopoietic engraftment within deep bone marrow (BM) remains challenging. We addressed this challenge by developing a dual CEST-MRI and fluorescent reporter system for cross-validated detection of reporter-positive donor-derived hematopoietic cells and their progeny in BM, with fluorescence-based assessment of HSPC-enriched compartments.Methods A lentiviral dual-reporter cassette co-expressing the red fluorescent protein mScarlet-I (mScarlet) and the CEST-MRI reporter SuperCESTide (SC) via a T2A linker was evaluated in CT26 colon carcinoma cells in vitro and in a bilateral flank tumor model with contralateral reporter-transduced and non-transduced tumors in BALB/c mice (n = 6 tumors per group). In vivo optical imaging, CEST-MRI, ex vivo optical imaging, fluorescence microscopy, and histology were used for validation. The platform was then applied to primary murine hematopoietic lineage-negative (Lin⁻) cells and Lin⁻Sca-1⁺c-Kit⁺ (LSKs), with reporter expression analyzed by fluorescence microscopy and flow cytometry. Reporter-transduced Lin⁻ cells were transplanted into C57BL/6J mice after half-body irradiation, and engraftment was assessed 8 weeks later by whole-body fluorescence imaging, femoral CEST-MRI, intravital calvarial microscopy, ex vivo confocal microscopy, optical imaging, and flow cytometry. Femoral CEST-MRI was compared among non-irradiated controls, irradiated recipients transplanted with non-reporter-transduced Lin⁻ cells, and irradiated recipients transplanted with mScarlet-SC reporter-transduced Lin⁻ cells.Results The dual mScarlet-SuperCESTide reporter showed efficient expression in CT26 cells and generated detectable red fluorescence and increased CEST-MRI contrast in reporter-positive tumors compared with contralateral non-transduced controls. Ex vivo optical imaging and histology confirmed reporter expression in tumor tissue. In murine BM-derived Lin⁻ cells, reporter expression was detected by fluorescence microscopy and flow cytometry, supporting feasibility in sensitive hematopoietic populations. Following transplantation, reporter-transduced Lin⁻ cells were detected eight weeks after engraftment using fluorescence imaging and femoral CEST-MRI. The recipients with reporter-transduced Lin⁻ cells showed increased femoral CEST contrast associated with the reporter compared with both irradiated recipients transplanted with non-transduced Lin⁻ cells and non-irradiated BM controls. Additionally, intravital microscopy visualized mScarlet⁺ cells within the BM niches of the calvarium. Ex vivo confocal microscopy and optical imaging confirmed reporter retention in BM, and flow cytometry confirmed mScarlet signal within Lin⁻ and LSK hematopoietic compartments in reporter-transduced recipients compared with non-transduced controls.Conclusion We developed a dual CEST-fluorescent reporter platform that enables cross-validated imaging of reporter-transduced hematopoietic cells in deep BM. By integrating noninvasive CEST-MRI with fluorescence-based cellular validation, this feasibility study establishes a preclinical framework for cross-validated, noninvasive assessment of engineered hematopoietic cell localization and persistence in vivo and supports future evaluation of the platform for serial imaging.
SN - 1838-7640
ER -