Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 24 min ago
Peer-reviewedCC BY-NC-ND 4.0Endocrine

Carotid plaque detection in patients with type 2 diabetes: development, interpretability, and limited transportability of a clinical model

  1. 1Department of Endocrinology, Liangjiang Hospital of Chongqing Medical University, Chongqing, 401121 China
  2. 2Department of Neurology, The People’s Hospital of Kaizhou District in Chongqing, Chongqing, 405499 China

Abstract

Objective: To develop and evaluate a parsimonious model for detecting prevalent carotid plaque in type 2 diabetes mellitus (T2DM), and to assess its interpretability, robustness, and transportability.

Methods: This retrospective cross-sectional study enrolled 2,035 hospitalized patients with T2DM, randomly assigned 70:30 to training and test sets. Bidirectional stepwise regression screened 39 candidate variables; stability was assessed by bootstrap resampling (1,000 replicates) and penalized regression. Performance was compared with random forest and XGBoost, and TreeSHAP was used for interpretability. Interaction terms, a non-medication model, and high-sensitivity thresholds were evaluated. The model was applied to an independent cohort of 3,191 health-screening individuals, with updating assessed by split-half validation.

Results: Eight predictors were retained. The test-set AUC was 0.827 (95% CI 0.791–0.862), versus 0.804 for random forest and 0.816 for XGBoost (P = 0.023 versus random forest). Only age and statin use were selected in 100% of bootstrap resamples. Removing statin use and GLP-1RA lowered the AUC to 0.787 (ΔAUC − 0.040, P < 0.001), retaining a history of coronary heart disease. No interaction term was significant (joint P = 0.511). In the external cohort, the AUC was 0.666 with marked miscalibration; updating left discrimination unchanged, and at 85% sensitivity, specificity was 33.4%.

Conclusion: An eight-variable logistic model using routinely available variables performed comparably to machine learning models for detecting prevalent carotid plaque in the development cohort. However, variable selection was unstable, and statin use was the strongest but indication-confounded correlate. External discrimination was moderate and did not improve after recalibration, indicating limited transportability. The model is best regarded as an exploratory candidate requiring further setting-specific validation, rather than one that may already aid in the detection of clinical cases.

Related

  1. Development and validation of a novel metabolic-inflammatory health-related nomogram for predicting in-hospital mortality in older patients with type 2 diabetes mellitus combined with cardiovascular disease
    Juntao Tan, Tailin Dong, Yuxin He +1
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Development and internal validation of a clinical risk score for early delirium detection in older emergency department patients
    Pitsucha Sanguanwit, Prapaporn Sotakul, Varaporn Wangviboonchai
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicineCrossref
  3. Decoding the Prognosis of Sepsis-Induced Acute Lung Injury: Machine Learning Model Development and SHAP Interpretability Analysis Based on Critical Care Databases
    Yan Wang, Ke Ma, Huali Zhang +1
    DiagnosticsPeer-reviewedCC BY 4.0Full textGeneral medicinePMC
  4. Development and Validation of a One-Step Multiplex RT-qPCR Assay for BCR-ABL1 Transcript Detection and Monitoring in Moroccan Chronic Myeloid Leukemia Patients
    Abdenacer Benchrifa, Basma Albanyahyati, Mounyr Balouiri +4
    Asian Pacific Journal of Cancer Prevention : APJCPPeer-reviewedCC BY-NC 4.0Full textGeneral medicinePMC
  5. Ethnic Influence on the Development of Aortic Stenosis in Patients with Diabetes: A Two-Hit Model of Myocardial Fibrosis and an Integrated Framework for Personalised Management.
    Sunil K Ohri
    Journal of personalized medicinePeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
BibTeX
@article{liu2026carotid,
  title = {{Carotid plaque detection in patients with type 2 diabetes: development, interpretability, and limited transportability of a clinical model}},
  author = {Xun Liu and Gang Xu and Xiao ju Wang},
  journal = {Endocrine},
  year = {2026},
  month = nov,
  doi = {10.1007/s12020-026-04828-9},
  url = {https://doi.org/10.1007/s12020-026-04828-9},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Carotid plaque detection in patients with type 2 diabetes: development, interpretability, and limited transportability of a clinical model
AU  - Xun Liu
AU  - Gang Xu
AU  - Xiao ju Wang
PY  - 2026
DA  - 2026/11/16
JO  - Endocrine
DO  - 10.1007/s12020-026-04828-9
UR  - https://doi.org/10.1007/s12020-026-04828-9
AB  - Objective: To develop and evaluate a parsimonious model for detecting prevalent carotid plaque in type 2 diabetes mellitus (T2DM), and to assess its interpretability, robustness, and transportability.  Methods: This retrospective cross-sectional study enrolled 2,035 hospitalized patients with T2DM, randomly assigned 70:30 to training and test sets. Bidirectional stepwise regression screened 39 candidate variables; stability was assessed by bootstrap resampling (1,000 replicates) and penalized regression. Performance was compared with random forest and XGBoost, and TreeSHAP was used for interpretability. Interaction terms, a non-medication model, and high-sensitivity thresholds were evaluated. The model was applied to an independent cohort of 3,191 health-screening individuals, with updating assessed by split-half validation.  Results: Eight predictors were retained. The test-set AUC was 0.827 (95% CI 0.791–0.862), versus 0.804 for random forest and 0.816 for XGBoost (P = 0.023 versus random forest). Only age and statin use were selected in 100% of bootstrap resamples. Removing statin use and GLP-1RA lowered the AUC to 0.787 (ΔAUC − 0.040, P < 0.001), retaining a history of coronary heart disease. No interaction term was significant (joint P = 0.511). In the external cohort, the AUC was 0.666 with marked miscalibration; updating left discrimination unchanged, and at 85% sensitivity, specificity was 33.4%.  Conclusion: An eight-variable logistic model using routinely available variables performed comparably to machine learning models for detecting prevalent carotid plaque in the development cohort. However, variable selection was unstable, and statin use was the strongest but indication-confounded correlate. External discrimination was moderate and did not improve after recalibration, indicating limited transportability. The model is best regarded as an exploratory candidate requiring further setting-specific validation, rather than one that may already aid in the detection of clinical cases.
SN  - 1355-008X
SN  - 1559-0100
ER  -