Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 56 min ago
PreprintCC BY 4.0HAL

Physics-Informed Self-Supervised Learning for Joint Wire Calibration and Interaction Position Reconstruction in Multi-Wire Parallel Plate Avalanche Counters

Abstract

Scientific instruments require accurate calibration to convert detector signals into reliable physical observables. Conventional calibration procedures typically rely on dedicated calibration measurements, analytical response models or labelled reference data, limiting their ability to adapt to changing operating conditions and detector aging. We present a physics-informed self-supervised learning framework that jointly performs wire calibration and interaction position reconstruction in Multi-Wire Parallel Plate Avalanche Counters (MWPPACs) without requiring labelled position measurements or dedicated calibration runs. The method formulates detector calibration as a latent optimization problem in which global wire gains and event-wise interaction positions are estimated simultaneously using supervision derived exclusively from detector geometry and charge-energy consistency constraints. A detector-independent neural network reconstructs sub-wire interaction positions from local charge distributions, eliminating the need to assume analytical induction profiles by learning the detector response directly from experimental data. The end-to-end differentiable framework enables continuous detector self-calibration while improving the uniformity and accuracy of position reconstruction. Experimental evaluation on the entrance MWPPAC tracking detectors of the VAMOS++ magnetic spectrometer demonstrates stable convergence, improved spatial homogeneity and enhanced position resolution. Beyond the detector studied, the method establishes a general framework for physics-informed self-supervised calibration of scientific instruments and is a step toward autonomous intelligent instrumentation capable of continuous adaptation during operation. In this paradigm, detector calibration is no longer a prerequisite for an experiment but an integral part of the measurement process itself.

Related

  1. Physics-Informed Neural Networks for Depth-Averaged Granular Avalanche Dynamics on Curved Topography
    Pujan Pranavkumar Purohit, Pradyumn Singh Sikarwar, Vishal Sharma +1
    arXivPreprintCC BY-NC-ND 4.0Full textCondensed matterFluid dynamicsarXiv
  2. Scene-based semi-supervised algorithm for self-calibration of polarization imaging systems
    Qiwei Liu, Xia Wang, Jiaan Xue +2
    Optics ExpressPeer-reviewedPublisher termsOptics & photonicsCrossref
  3. Physics-Informed Neural Networks for Depth-Averaged Avalanche Dynamics
    Pradyumn Singh Sikarwar, Vishal Sharma, Gaurav Bhutani
    arXivPreprintCC BY-NC-ND 4.0Full textCondensed matterFluid dynamicsarXiv
  4. Probe-aware self-supervised neural network for X-ray holographic reconstruction
    Jiarui Hu, Yu Hu, Guangcai Chang +3
    Optics ExpressPeer-reviewedPublisher termsApplied physics & instrumentationCrossref
  5. Real-Time Atomic-Resolution Electron Phase Imaging without Probe Calibration via Ptychography-Supervised Learning
    H. Yue, C. -C. Chen, C. -N. Hsiao +4
    arXivPreprintarXiv licenceFull textCondensed matterarXiv
BibTeX
@misc{lemasson2026physicsinformed,
  title = {{Physics-Informed Self-Supervised Learning for Joint Wire Calibration and Interaction Position Reconstruction in Multi-Wire Parallel Plate Avalanche Counters}},
  author = {Antoine Lemasson and Maurycy Rejmund},
  howpublished = {HAL},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.28604},
  eprint = {2609.28604},
  archivePrefix = {arXiv},
  url = {https://hal.science/hal-05780385v1},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Physics-Informed Self-Supervised Learning for Joint Wire Calibration and Interaction Position Reconstruction in Multi-Wire Parallel Plate Avalanche Counters
AU  - Antoine Lemasson
AU  - Maurycy Rejmund
PY  - 2026
DA  - 2026/09/23
PB  - HAL
DO  - 10.48550/arxiv.2609.28604
UR  - https://hal.science/hal-05780385v1
AB  - Scientific instruments require accurate calibration to convert detector signals into reliable physical observables. Conventional calibration procedures typically rely on dedicated calibration measurements, analytical response models or labelled reference data, limiting their ability to adapt to changing operating conditions and detector aging. We present a physics-informed self-supervised learning framework that jointly performs wire calibration and interaction position reconstruction in Multi-Wire Parallel Plate Avalanche Counters (MWPPACs) without requiring labelled position measurements or dedicated calibration runs. The method formulates detector calibration as a latent optimization problem in which global wire gains and event-wise interaction positions are estimated simultaneously using supervision derived exclusively from detector geometry and charge-energy consistency constraints. A detector-independent neural network reconstructs sub-wire interaction positions from local charge distributions, eliminating the need to assume analytical induction profiles by learning the detector response directly from experimental data. The end-to-end differentiable framework enables continuous detector self-calibration while improving the uniformity and accuracy of position reconstruction. Experimental evaluation on the entrance MWPPAC tracking detectors of the VAMOS++ magnetic spectrometer demonstrates stable convergence, improved spatial homogeneity and enhanced position resolution. Beyond the detector studied, the method establishes a general framework for physics-informed self-supervised calibration of scientific instruments and is a step toward autonomous intelligent instrumentation capable of continuous adaptation during operation. In this paradigm, detector calibration is no longer a prerequisite for an experiment but an integral part of the measurement process itself.
ER  -