Purpose: Transradial intracranial aneurysm embolization is well established, but experience with large-bore 7F sheath-based guide platforms remains comparatively limited. We evaluated the technical feasibility and periprocedural outcomes of a 7F sheath-compatible 0.087-inch guide catheter for transradial intracranial aneurysm embolization.

Materials and Methods: In this single-arm, noncomparative retrospective study, we reviewed consecutive patients who underwent attempted transradial intracranial aneurysm embolization using the NeuGlide as the primary guide catheter at a single center between January 2025 and May 2026. Preaccess radial ultrasonography was performed in all patients, and radial diameter ≥1.7 mm was required for 7F access. The primary outcome was completion of the intended treatment through radial access without femoral conversion.

Results: Target-vessel catheterization was achieved in 71/74 procedures (95.9%), and radial procedural completion in 69/74 (93.2%; 95% confidence interval, 85.1–97.1%). Three procedures required femoral conversion, and 2 were terminated without aneurysm treatment; overall treatment completion was 72/74 (97.3%). Guide instability occurred in 2 procedures: 1 repositioning-only event and 1 event resulting in femoral conversion; no guide exchanges occurred. Seven patients had 9 access-site component events, all managed conservatively; all 6 hematomas were low-grade (EASY I–II). Radial artery occlusion was identified in 1/15 patients formally assessed.

Conclusion: In this radial-first cohort, the 7F sheath-compatible 0.087-inch NeuGlide guide catheter achieved a 93.2% radial procedural completion rate across multiple intracranial aneurysm treatment strategies. These findings support the NeuGlide as a technically feasible and versatile large-bore transradial platform in appropriately selected patients.

Related

  1. Quantifying procedural burden during stent-assisted coil embolization for unruptured intracranial aneurysms: development of the aneurysm endovascular procedural complexity score and internal validation of a multivariable complication model
    Yuxiang Huang, E Zhu, Zijun Huang +4
    Frontiers in NeurologyPeer-reviewedCC BY 4.0NeurologyCrossref
  2. “Pave and Cover” strategy for Rotarex-assisted endovascular repair of thrombosed popliteal artery aneurysm to mitigate distal embolization
    Je Hyung Park, Hyuk Jae Jung, Sang-Su Lee
    Journal of vascular surgery cases and innovative techniquesPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  3. “Pave and Cover” strategy for Rotarex-assisted endovascular repair of thrombosed popliteal artery aneurysm to mitigate distal embolization
    Je Hyung Park, MD, Hyuk Jae Jung, MD, PhD, Sang-Su Lee, MD, PhD
    Journal of Vascular Surgery Cases and Innovative TechniquesPeer-reviewedCC BY-NC-NDFull textCardiovascular medicineSurgery & anaesthesiaDOAJEurope PMCPMC
  4. Hybrid Occipital Artery–AICA Bypass Followed by Endovascular Embolization for a Radiation-Induced Dissecting AICA Aneurysm in a Pediatric Patient
    Xiaowen Wang, Peixi Liu, Revaz Shalibashvili +7
    Neurosurgery PracticePeer-reviewedCC BY-NC-ND 4.0Full textNeurologyPMC
  5. Vascular Tissue-Type Plasminogen Activator Promotes Intracranial Aneurysm Formation
    Paul-Emile Labeyrie, Romain Goulay, Sara Martinez de Lizarrondo +11
    StrokePeer-reviewedLicence not statedFull text22 citedNeurologyHAL
BibTeX
@article{hajj2026transradial,
  title = {{Transradial Intracranial Aneurysm Embolization Using a 7F Sheath-Compatible 0.087-Inch Guide Catheter: A Single-Center Retrospective Study}},
  author = {Gerard El Hajj and Dani Douri and Jacob Teigen and Charles Garrity and Waleed Brinjikji and Giuseppe Lanzino and Harry Cloft and Lorenzo Rinaldo},
  journal = {Neurointervention},
  year = {2026},
  month = oct,
  doi = {10.5469/neuroint.2026.01032},
  url = {https://doi.org/10.5469/neuroint.2026.01032},
  note = {CC BY-NC 4.0},
}
RIS
TY  - JOUR
TI  - Transradial Intracranial Aneurysm Embolization Using a 7F Sheath-Compatible 0.087-Inch Guide Catheter: A Single-Center Retrospective Study
AU  - Gerard El Hajj
AU  - Dani Douri
AU  - Jacob Teigen
AU  - Charles Garrity
AU  - Waleed Brinjikji
AU  - Giuseppe Lanzino
AU  - Harry Cloft
AU  - Lorenzo Rinaldo
PY  - 2026
DA  - 2026/10/26
JO  - Neurointervention
DO  - 10.5469/neuroint.2026.01032
UR  - https://doi.org/10.5469/neuroint.2026.01032
AB  - Purpose: Transradial intracranial aneurysm embolization is well established, but experience with large-bore 7F sheath-based guide platforms remains comparatively limited. We evaluated the technical feasibility and periprocedural outcomes of a 7F sheath-compatible 0.087-inch guide catheter for transradial intracranial aneurysm embolization.  Materials and Methods: In this single-arm, noncomparative retrospective study, we reviewed consecutive patients who underwent attempted transradial intracranial aneurysm embolization using the NeuGlide as the primary guide catheter at a single center between January 2025 and May 2026. Preaccess radial ultrasonography was performed in all patients, and radial diameter ≥1.7 mm was required for 7F access. The primary outcome was completion of the intended treatment through radial access without femoral conversion.  Results: Target-vessel catheterization was achieved in 71/74 procedures (95.9%), and radial procedural completion in 69/74 (93.2%; 95% confidence interval, 85.1–97.1%). Three procedures required femoral conversion, and 2 were terminated without aneurysm treatment; overall treatment completion was 72/74 (97.3%). Guide instability occurred in 2 procedures: 1 repositioning-only event and 1 event resulting in femoral conversion; no guide exchanges occurred. Seven patients had 9 access-site component events, all managed conservatively; all 6 hematomas were low-grade (EASY I–II). Radial artery occlusion was identified in 1/15 patients formally assessed.  Conclusion: In this radial-first cohort, the 7F sheath-compatible 0.087-inch NeuGlide guide catheter achieved a 93.2% radial procedural completion rate across multiple intracranial aneurysm treatment strategies. These findings support the NeuGlide as a technically feasible and versatile large-bore transradial platform in appropriately selected patients.
SN  - 2093-9043
SN  - 2233-6273
ER  -