Operando Electrochemical Fluorescence Microscopy Highlights Local Buffering and Mass Transport Effects in Polymer-Promoted Electrocatalysis.
- 1Leiden University , Faculty of Science, Leiden Institute of Chemistry, Einsteinweg 55, Leiden2333 CC, The Netherlands.
Abstract
Many electrocatalytic reactions proceed via proton-coupled electron transfer (PCET) mechanisms, which can be promoted by protic polymer coatings. However, polymers modulate the local reaction environment in many ways. To deconvolute the effect of local pH in protic polymer coatings from other contributions, we developed a method for operando determination of in-polymer pH values using electrochemical fluorescence microscopy. Polyethylenimine (PEI) was equipped with a fluorescent pH probe, coated on polycrystalline gold, and electrochemical hydrogen evolution was applied as a pH-sensitive model reaction. Temporal changes in the average pH values across the entire thickness of the polymer film were quantified by widefield microscopy, while the spatial distribution of pH profiles within the films was determined by confocal laser scanning microscopy (CLSM). Complementing the experimental results with finite-element modeling identified two polymer-induced effects: (i) local differences in the mass transport of the proton donors and (ii) a pronounced local buffering by the highly concentrated ammonium groups inside the polymer coating. The latter was corroborated by linear sweep voltammetry (LSV): while the buffering PEI coating decreased the onset potential of hydrogen evolution, the control polymers poly(vinyl alcohol) and PiperION, which cannot be deprotonated in the aqueous pH window, did not promote electrocatalysis. These findings highlight the operando pH modulation by protic polymer coatings, and understanding this phenomenon will be crucial for rational design of polymer coatings for PCET reactions.
Related
- Uncovering Heterogeneous Energetic Trajectories in NiFe Oxygen Evolution Electrocatalysis through Integrated Raman, Electrochemical and Microkinetic Analysis
- Aryldiazonium reduction mechanism deciphered by scanning electrochemical microscopy through an EC’ process
- Addition-Fragmentation-Transfer Monitored by Fluorescence Lifetime Imaging Microscopy.
- Electrochemical Fluorescence Switching in Rhodamine-Ferrocene Dyads: Spatiotemporal Control in Biomimetic Membranes
- Preventing oxaliplatin-induced peripheral neuropathy with a Pt(IV)-Mn(II) prodrug: Toxicity, behavioral and X-ray fluorescence microscopy studies
BibTeX
@article{hardt2026operando,
title = {{Operando Electrochemical Fluorescence Microscopy Highlights Local Buffering and Mass Transport Effects in Polymer-Promoted Electrocatalysis.}},
author = {Steffen Hardt and Katherine J Levey and Mark Aarts and Bonho Koo and Lars J C Jeuken and Marc T M Koper},
journal = {Journal of the American Chemical Society},
year = {2026},
month = oct,
doi = {10.1021/jacs.6c11297},
url = {https://europepmc.org/article/MED/42912288},
note = {CC BY},
}
RIS
TY - JOUR
TI - Operando Electrochemical Fluorescence Microscopy Highlights Local Buffering and Mass Transport Effects in Polymer-Promoted Electrocatalysis.
AU - Steffen Hardt
AU - Katherine J Levey
AU - Mark Aarts
AU - Bonho Koo
AU - Lars J C Jeuken
AU - Marc T M Koper
PY - 2026
DA - 2026/10/01
JO - Journal of the American Chemical Society
DO - 10.1021/jacs.6c11297
UR - https://europepmc.org/article/MED/42912288
AB - Many electrocatalytic reactions proceed via proton-coupled electron transfer (PCET) mechanisms, which can be promoted by protic polymer coatings. However, polymers modulate the local reaction environment in many ways. To deconvolute the effect of local pH in protic polymer coatings from other contributions, we developed a method for operando determination of in-polymer pH values using electrochemical fluorescence microscopy. Polyethylenimine (PEI) was equipped with a fluorescent pH probe, coated on polycrystalline gold, and electrochemical hydrogen evolution was applied as a pH-sensitive model reaction. Temporal changes in the average pH values across the entire thickness of the polymer film were quantified by widefield microscopy, while the spatial distribution of pH profiles within the films was determined by confocal laser scanning microscopy (CLSM). Complementing the experimental results with finite-element modeling identified two polymer-induced effects: (i) local differences in the mass transport of the proton donors and (ii) a pronounced local buffering by the highly concentrated ammonium groups inside the polymer coating. The latter was corroborated by linear sweep voltammetry (LSV): while the buffering PEI coating decreased the onset potential of hydrogen evolution, the control polymers poly(vinyl alcohol) and PiperION, which cannot be deprotonated in the aqueous pH window, did not promote electrocatalysis. These findings highlight the operando pH modulation by protic polymer coatings, and understanding this phenomenon will be crucial for rational design of polymer coatings for PCET reactions.
SN - 0002-7863
SN - 1520-5126
ER -