Reactor Antineutrino Detection with JUNO-TAO: Commissioning Performance and First Results

Abstract

The Taishan Antineutrino Observatory (TAO) is a satellite experiment of JUNO, designed to measure the reactor antineutrino energy spectrum with high precision at a baseline of 43.2~m from a reactor core using a 2.8-ton spherical liquid-scintillator detector, 1.8~m in diameter, operated at -50 degree and instrumented with 4,024 silicon photomultiplier tiles. The TAO detector installation was completed in 2025, and physics data taking began on 10 February 2026. This paper reports the detector design, calibration strategy, and performance based on commissioning data and the first physics runs. Stable cryogenic operation has been achieved, and about 90\% of the readout channels are retained for physics analysis after channel-quality selections. The detector light yield is measured to be about 4000~photoelectrons/MeV after correction for dark noise and optical crosstalk, using neutron capture on hydrogen in inverse beta decay (IBD) events. The energy resolution is about 2.8\% for 68Ge at the detector center and about 3.7\% for 137Cs at R=193~mm. This energy-resolution performance is among the best reported for reactor-antineutrino detectors and enables TAO to measure the reactor antineutrino spectrum with high precision. Within the fiducial volume of R < 800~mm, the vertex reconstruction bias remains within ± 30 mm, and the resolution is approximately 70 mm over most of the fiducial volume. The combined muon-tagging efficiency of the veto system is about 97\%. Using 31.3 days of reactor-on data and 29.4 days of reactor-off data, a significant excess of IBD candidates is observed in the reactor-on sample relative to the reactor-off sample, with candidate rates of 2900±10 events/day and 419±4 events/day, respectively. The results demonstrate that TAO has reached a high performance level in reactor antineutrino measurement.

Related

  1. Natural Chlorine Enhances Antineutrino Detection in the Deep Ocean
    Ruike Cao, Iwan Morton-Blake, Donglian Xu +16
    arXivPreprintCC BY 4.0Full textInstrumentation & methodsHigh-energy & particle physicsarXiv
  2. QUIJOTE scientific results - XX. Commissioning and First Results from the Thirty and Forty Gigahertz Instrument (TFGI)
    M Fernandez-Torreiro, J.A Rubino-Martin, R.T Genova-Santos +16
    Publ.Astron.Soc.Pac.Peer-reviewedCC BYGeneral astronomyApplied physics & instrumentationHAL
  3. Commissioning and Performance of the LHCb Upstream Tracker
    D. Andreou, M. Artuso, J. Bartz +130
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationHigh-energy & particle physicsarXiv
  4. Commissioning and Performance of the Time-of-Flight Detector for the T2K Neutrino Oscillation Experiment
    C Alt, L Amziane, N Baudis +23
    HALPreprintarXiv licenceFull textApplied physics & instrumentationHigh-energy & particle physicsHALarXiv
  5. Surface Commissioning and Performance of the sMDT Muon Chambers for the ATLAS HL-LHC Upgrade
    Jiajin Ge, Elena Voevodina, Hubert Kroha +21
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationarXiv
BibTeX
@misc{collaboration2026reactor,
  title = {{Reactor Antineutrino Detection with JUNO-TAO: Commissioning Performance and First Results}},
  author = {JUNO Collaboration},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.23331},
  eprint = {2610.23331},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.23331},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Reactor Antineutrino Detection with JUNO-TAO: Commissioning Performance and First Results
AU  - JUNO Collaboration
PY  - 2026
DA  - 2026/10/16
PB  - arXiv
DO  - 10.48550/arxiv.2610.23331
UR  - https://arxiv.org/abs/2610.23331
AB  - The Taishan Antineutrino Observatory (TAO) is a satellite experiment of JUNO, designed to measure the reactor antineutrino energy spectrum with high precision at a baseline of 43.2~m from a reactor core using a 2.8-ton spherical liquid-scintillator detector, 1.8~m in diameter, operated at -50 degree and instrumented with 4,024 silicon photomultiplier tiles. The TAO detector installation was completed in 2025, and physics data taking began on 10 February 2026. This paper reports the detector design, calibration strategy, and performance based on commissioning data and the first physics runs. Stable cryogenic operation has been achieved, and about 90\% of the readout channels are retained for physics analysis after channel-quality selections. The detector light yield is measured to be about 4000~photoelectrons/MeV after correction for dark noise and optical crosstalk, using neutron capture on hydrogen in inverse beta decay (IBD) events. The energy resolution is about 2.8\% for ^68Ge at the detector center and about 3.7\% for ^137Cs at R=193~mm. This energy-resolution performance is among the best reported for reactor-antineutrino detectors and enables TAO to measure the reactor antineutrino spectrum with high precision. Within the fiducial volume of R < 800~mm, the vertex reconstruction bias remains within ± 30 mm, and the resolution is approximately 70 mm over most of the fiducial volume. The combined muon-tagging efficiency of the veto system is about 97\%. Using 31.3 days of reactor-on data and 29.4 days of reactor-off data, a significant excess of IBD candidates is observed in the reactor-on sample relative to the reactor-off sample, with candidate rates of 2900±10 events/day and 419±4 events/day, respectively. The results demonstrate that TAO has reached a high performance level in reactor antineutrino measurement.
ER  -