Skip to content
DraconiticResearch
Search Sources API
203,948 studies31 sourcesUpdated 6 min ago
PreprintarXiv licencearXiv

An Absolute Acoustic Readout of Plate Wave Speed for Bullion Authentication, Using a Measured Fill-Factor Correction for Struck Coins

Abstract

Acoustic "ping" testing of bullion is empirical: it compares a coin's ringing frequency with frequencies recorded for the same coin type, so it cannot assess a specimen absent from the reference library. This work replaces the comparison with an absolute measurement, computed from the measured resonance and geometry through a physical model rather than retrieved from a library. Free-plate flexural resonance is calibrated on five machined aluminium discs (a/t=2.58--$10.75$), recovering an empirical finite-thickness coefficient β=0.895±0.047 that reduces the worst-case departure from thin-plate theory from 8.9% to 0.75%. A fill factor, the ratio of a coin's displaced volume to its nominal cylinder, supplies the effective thickness that relief hides from calipers, extending the calibration to struck coins. The readout is the plate wave speed cp=√(E/ρ(1−ν2)), a material constant, conditioned on an assumed Poisson's ratio. On six struck 0.999 copper rounds not used in the calibration it recovers a Young's modulus of 119.1±6.7 GPa, inside the accepted 110 to 128 GPa. The recovered wave speeds form distinct observed groups across the measured specimens, with the strongest independent validation provided by these copper rounds. The $(3,0)/(2,0)$ mode ratio falls below its thin-plate value in thirteen of sixteen specimens (one-sided sign test, p=0.011), as finite-thickness theory predicts. Weighing displaced mass to 0.1 mg rather than 0.1 g cut per-specimen volume uncertainty from 1.6% to 30% to 0.5% to 2.6% and shrank an apparent 11% design-dependent bias to a 4.7% residual on one deeply relieved silver design. The readout is now limited by tabulated elastic constants and the assumed Poisson's ratio, not by the acoustics, which are reproducible to 0.15%.

Related

  1. Co-localized optical and acoustic defect modes enable resonantly enhanced photoelastic readout in a one-dimensional phoxonic multilayer
    Arafa H. Aly
    Scientific ReportsPeer-reviewedCC BY 4.0Full textOptics & photonicsCrossrefDOAJ
  2. Hybrid Authentication Protocols for Advanced Quantum Networks
    Suchetana Goswami, Mina Doosti, Elham Kashefi
    HALPreprintLicence not statedQuantum physics & quantum informationHAL
  3. Security authentication and 3D tracking of unmanned autonomous vehicles with optical ID tags
    JIHEON LEE, saurabh goswami, Bahram Javidi
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  4. Physical layer authentication for fiber-optic links based on multi-wavelength chromatic dispersion fingerprints
    Daisheng Zhang, Xiangqing Wang, Dongfei Wang +1
    Optics ExpressPeer-reviewedPublisher termsOptics & photonicsCrossref
  5. Unconditional authentication in quantum key distribution via hybrid entangled physical unclonable functions
    Nicolas Laurent-Puig, Mina Doosti, Adriano Innocenzi +1
    Physical Review ResearchPeer-reviewedPublisher termsAtomic, molecular & optical physicsCrossref
BibTeX
@misc{dong2026absolute,
  title = {{An Absolute Acoustic Readout of Plate Wave Speed for Bullion Authentication, Using a Measured Fill-Factor Correction for Struck Coins}},
  author = {Sylvia Dong and Takyiu Liu},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.29194},
  eprint = {2610.29194},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.29194},
}
RIS
TY  - UNPB
TI  - An Absolute Acoustic Readout of Plate Wave Speed for Bullion Authentication, Using a Measured Fill-Factor Correction for Struck Coins
AU  - Sylvia Dong
AU  - Takyiu Liu
PY  - 2026
DA  - 2026/10/21
PB  - arXiv
DO  - 10.48550/arxiv.2610.29194
UR  - https://arxiv.org/abs/2610.29194
AB  - Acoustic "ping" testing of bullion is empirical: it compares a coin's ringing frequency with frequencies recorded for the same coin type, so it cannot assess a specimen absent from the reference library. This work replaces the comparison with an absolute measurement, computed from the measured resonance and geometry through a physical model rather than retrieved from a library. Free-plate flexural resonance is calibrated on five machined aluminium discs (a/t=2.58--$10.75$), recovering an empirical finite-thickness coefficient β=0.895±0.047 that reduces the worst-case departure from thin-plate theory from 8.9% to 0.75%. A fill factor, the ratio of a coin's displaced volume to its nominal cylinder, supplies the effective thickness that relief hides from calipers, extending the calibration to struck coins. The readout is the plate wave speed c_p=√(E/ρ(1−ν^2)), a material constant, conditioned on an assumed Poisson's ratio. On six struck 0.999 copper rounds not used in the calibration it recovers a Young's modulus of 119.1±6.7 GPa, inside the accepted 110 to 128 GPa. The recovered wave speeds form distinct observed groups across the measured specimens, with the strongest independent validation provided by these copper rounds. The $(3,0)/(2,0)$ mode ratio falls below its thin-plate value in thirteen of sixteen specimens (one-sided sign test, p=0.011), as finite-thickness theory predicts. Weighing displaced mass to 0.1 mg rather than 0.1 g cut per-specimen volume uncertainty from 1.6% to 30% to 0.5% to 2.6% and shrank an apparent 11% design-dependent bias to a 4.7% residual on one deeply relieved silver design. The readout is now limited by tabulated elastic constants and the assumed Poisson's ratio, not by the acoustics, which are reproducible to 0.15%.
ER  -