Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated just now
Peer-reviewedCC BY 4.0Annals of Noninvasive Electrocardiology

Low‐Voltage Area–Guided Ablation for Persistent Atrial Fibrillation: A Meta‐Analysis of Randomized Trials

13 affiliations
  1. 1Saint Louis University St. Louis Missouri USA
  2. 2Faculty of Medicine Al‐Quds University Jerusalem Palestine
  3. 3Faculty of Medicine Alexandria University Alexandria Egypt
  4. 4Faculty of Medicine Mansoura University Mansoura Egypt
  5. 5Bahry University Khartoum Sudan
  6. 6Faculty of Medicine Atilim University Ankara Turkey
  7. 7Palestinian Ministry of Health Jerusalem Palestine
  8. 8Princess Basma Hospital Irbid Jordan
  9. 9Department of Pharmacology, Jawaharlal Nehru Medical College Aligarh Muslim University Aligarh India
  10. 10Faculty of Medicine Al‐Azhar University Damietta Egypt
  11. 11School of Nursing Tennessee State University Nashville Tennessee USA
  12. 12Department of Nursing Vanderbilt University Medical Center (VUMC) Nashville Tennessee USA
  13. 13Department of Internal Medicine Mayo Clinic Arizona Phoenix Arizona USA

Abstract

Background: Low‐voltage areas (LVAs) may represent arrhythmogenic substrate in persistent atrial fibrillation (AF), but the benefit of adjunctive LVA‐guided ablation remains uncertain.

Methods: We performed a PRISMA‐compliant systematic review and random‐effects meta‐analysis of randomized controlled trials comparing LVA‐guided ablation with non‐LVA‐guided strategies in persistent or non‐paroxysmal AF. Searches were updated through September 2, 2026. The primary outcome was atrial arrhythmia recurrence; time‐to‐event hazard ratios (HRs), repeat ablation, procedural outcomes, and safety were secondary outcomes.

Results: Eight randomized trials involving 1656 patients contributed to the primary analysis. LVA‐guided ablation reduced atrial arrhythmia recurrence (RR 0.77, 95% CI 0.65–0.91; p = 0.003; I 2 = 36.6%), although the 95% prediction interval included no benefit (0.51–1.17). The pooled HR was also favorable (HR 0.71, 95% CI 0.53–0.96; p = 0.026; I2 = 67.2%). Omitting IDEAL‐AF attenuated both estimates and eliminated most heterogeneity. Mapping‐before‐randomization trials with documented LVAs did not differ from randomization‐before‐mapping trials (interaction p = 0.76). Repeat ablation was reduced (RR 0.69, 95% CI 0.49–0.97), while procedure time, fluoroscopy time, and major safety outcomes were not significantly different.

Conclusions: LVA‐guided ablation was associated with fewer atrial arrhythmia recurrences and repeat procedures, but the pooled effect was strongly influenced by IDEAL‐AF and remained heterogeneous across documented‐LVA trials. Standardized mapping and ablation protocols are needed before the magnitude of benefit can be considered established.

Related

  1. Predictive Value of Left Atrial Strain Combined with Low-Voltage Substrate for Recurrence After Radiofrequency Catheter Ablation in Persistent Atrial Fibrillation
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Repeat Ablation for Persistent Atrial Fibrillation: CFA/DOA-Guided Substrate Ablation Versus Re-PVI Alone in the Prematurely Terminated Randomized AF-CAM Trial
    Stephan Willems, Pawel Kuklik, Peter Wohlmuth +12
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0Full textCardiovascular medicineCrossrefEurope PMC
  3. Low-Voltage Area Ablation for Persistent Atrial Fibrillation
    Pablo B. Nery, George A. Wells, Girish M. Nair +23
    JAMAPeer-reviewedLicence not statedFull textCardiovascular medicinePMC
  4. Impact of Body Mass Index on Recurrence After Catheter Ablation for Persistent Atrial Fibrillation in Patients With Left Atrial Low-Voltage Areas ― Prespecified Subanalysis of the SUPPRESS-AF Trial ―
    Nobuaki Tanaka, Masato Okada, Masaharu Masuda +24
    Circulation JournalPeer-reviewedLicence not statedFull textCardiovascular medicineJ-STAGE
  5. Left atrial low-voltage areas in persistent atrial fibrillation: from atrial cardiomyopathy marker to selective ablation target
    Jianan Zhao, Xiaojun Huang, Shujie Zhang +4
    Frontiers in Cardiovascular MedicinePeer-reviewedCC BY 4.0Cardiovascular medicineCrossref
BibTeX
@article{kivan2026lowvoltage,
  title = {{Low‐Voltage Area–Guided Ablation for Persistent Atrial Fibrillation: A Meta‐Analysis of Randomized Trials}},
  author = {Husam Kivan and Hamza Sondoqah and Abdulah Mohammad Abd Alhamed Abou Kaff and Mohamed Eldahrawy and Areej Makeineldein Mustafa and April Htoon and Farah Qandeel and Ahmad Alababneh and Ammar Khalid and Ahmed L. Youseif and Hamzah M. Alghzawi and Mohamed Ibraheem},
  journal = {Annals of Noninvasive Electrocardiology},
  year = {2026},
  month = nov,
  doi = {10.1111/anec.70249},
  url = {https://doi.org/10.1111/anec.70249},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Low‐Voltage Area–Guided Ablation for Persistent Atrial Fibrillation: A Meta‐Analysis of Randomized Trials
AU  - Husam Kivan
AU  - Hamza Sondoqah
AU  - Abdulah Mohammad Abd Alhamed Abou Kaff
AU  - Mohamed Eldahrawy
AU  - Areej Makeineldein Mustafa
AU  - April Htoon
AU  - Farah Qandeel
AU  - Ahmad Alababneh
AU  - Ammar Khalid
AU  - Ahmed L. Youseif
AU  - Hamzah M. Alghzawi
AU  - Mohamed Ibraheem
PY  - 2026
DA  - 2026/11/17
JO  - Annals of Noninvasive Electrocardiology
DO  - 10.1111/anec.70249
UR  - https://doi.org/10.1111/anec.70249
AB  - Background: Low‐voltage areas (LVAs) may represent arrhythmogenic substrate in persistent atrial fibrillation (AF), but the benefit of adjunctive LVA‐guided ablation remains uncertain.  Methods: We performed a PRISMA‐compliant systematic review and random‐effects meta‐analysis of randomized controlled trials comparing LVA‐guided ablation with non‐LVA‐guided strategies in persistent or non‐paroxysmal AF. Searches were updated through September 2, 2026. The primary outcome was atrial arrhythmia recurrence; time‐to‐event hazard ratios (HRs), repeat ablation, procedural outcomes, and safety were secondary outcomes.  Results: Eight randomized trials involving 1656 patients contributed to the primary analysis. LVA‐guided ablation reduced atrial arrhythmia recurrence (RR 0.77, 95% CI 0.65–0.91; p = 0.003; I 2 = 36.6%), although the 95% prediction interval included no benefit (0.51–1.17). The pooled HR was also favorable (HR 0.71, 95% CI 0.53–0.96; p = 0.026; I2 = 67.2%). Omitting IDEAL‐AF attenuated both estimates and eliminated most heterogeneity. Mapping‐before‐randomization trials with documented LVAs did not differ from randomization‐before‐mapping trials (interaction p = 0.76). Repeat ablation was reduced (RR 0.69, 95% CI 0.49–0.97), while procedure time, fluoroscopy time, and major safety outcomes were not significantly different.  Conclusions: LVA‐guided ablation was associated with fewer atrial arrhythmia recurrences and repeat procedures, but the pooled effect was strongly influenced by IDEAL‐AF and remained heterogeneous across documented‐LVA trials. Standardized mapping and ablation protocols are needed before the magnitude of benefit can be considered established.
SN  - 1082-720X
SN  - 1542-474X
ER  -