Enhancing Conjunctival Image-Based Anemia Classification Using Coordinate Attention on MobileNetV3-Small
Abstract
This study evaluates the integration of attention mechanisms (Efficient Channel Attention [ECA] and Coordinate Attention [CoordAtt]) into MobileNetV3-Small for preliminary conjunctival anemia screening. Using a single public dataset of 710 pediatric images from Ghana (CP-AnemiC dataset), the model was evaluated retrospectively via stratified 10-fold cross-validation (80%) and tested on a hold-out test set (20%). CoordAtt achieved the highest performance (Accuracy 78%, Sensitivity 84%, Specificity 70%, AUC 0.85), outperforming the Baseline (Accuracy 75%, Sensitivity 80%, Specificity 67%, AUC 0.80) and ECA (Accuracy 76%, Sensitivity 83%, Specificity 66%, AUC 0.81). A 95% Bootstrap BCa confidence interval test confirmed that the CoordAtt improvement over the Baseline is statistically significant for Accuracy, F1-Macro, Sensitivity, and AUC. Grad-CAM visualizations further showed more focused conjunctival localization. This improvement came with only a minimal increase in theoretical computational footprint (1.06M parameters, 0.0584 GFLOPs), keeping a lightweight profile similar to the Baseline (1.03M parameters, 0.0581 GFLOPs). These results show that CoordAtt improves classification performance without sacrificing computational efficiency, suggesting potential suitability for resource-constrained devices prior to clinical validation.
Related
- Enhancing prenatal diagnostic workflow: a deep learning-based system for multi-class fetal ultrasound classification across all gestational stages
- Feature-aware attention convolutional neural network for efficient pulmonary fibrosis classification from chest CT images with FPGA deployment
- TiLCA-Net: nuclei segmentation and classification in pathological images via task-specialized attention and efficient decoding
- CSwinFK: a bidirectional cross-attention CNN-Swin Transformer fusion model for fungal keratitis classification in in vivo confocal microscopy images
- Deep Learning for Multi‐Disease OCT Classification in Clinical Retina Practice Using Attention Mechanisms and Contrastive Learning
BibTeX
@article{mahendra2026enhancing,
title = {{Enhancing Conjunctival Image-Based Anemia Classification Using Coordinate Attention on MobileNetV3-Small}},
author = {Arnanda Asshaffa Mahendra and Aris Marjuni and Affandy and Muhammad Naufal},
journal = {Journal of Information Systems and Informatics},
year = {2026},
month = oct,
doi = {10.63158/journalisi.v8i5.1796},
url = {https://doi.org/10.63158/journalisi.v8i5.1796},
note = {CC BY},
}
RIS
TY - JOUR
TI - Enhancing Conjunctival Image-Based Anemia Classification Using Coordinate Attention on MobileNetV3-Small
AU - Arnanda Asshaffa Mahendra
AU - Aris Marjuni
AU - Affandy
AU - Muhammad Naufal
PY - 2026
DA - 2026/10/24
JO - Journal of Information Systems and Informatics
DO - 10.63158/journalisi.v8i5.1796
UR - https://doi.org/10.63158/journalisi.v8i5.1796
AB - This study evaluates the integration of attention mechanisms (Efficient Channel Attention [ECA] and Coordinate Attention [CoordAtt]) into MobileNetV3-Small for preliminary conjunctival anemia screening. Using a single public dataset of 710 pediatric images from Ghana (CP-AnemiC dataset), the model was evaluated retrospectively via stratified 10-fold cross-validation (80%) and tested on a hold-out test set (20%). CoordAtt achieved the highest performance (Accuracy 78%, Sensitivity 84%, Specificity 70%, AUC 0.85), outperforming the Baseline (Accuracy 75%, Sensitivity 80%, Specificity 67%, AUC 0.80) and ECA (Accuracy 76%, Sensitivity 83%, Specificity 66%, AUC 0.81). A 95% Bootstrap BCa confidence interval test confirmed that the CoordAtt improvement over the Baseline is statistically significant for Accuracy, F1-Macro, Sensitivity, and AUC. Grad-CAM visualizations further showed more focused conjunctival localization. This improvement came with only a minimal increase in theoretical computational footprint (1.06M parameters, 0.0584 GFLOPs), keeping a lightweight profile similar to the Baseline (1.03M parameters, 0.0581 GFLOPs). These results show that CoordAtt improves classification performance without sacrificing computational efficiency, suggesting potential suitability for resource-constrained devices prior to clinical validation.
SN - 2656-5935
SN - 2656-4882
ER -