Pain severity and setup error in palliative radiotherapy for spinal metastases: A secondary analysis of a prospective cohort☆

  1. 1Department of Radiation Oncology, Aichi Cancer Center, 1-1 Kanokoden, Chikusa-Ku, Nagoya, Aichi 464-8681, Japan

Abstract

Background and purpose: Patients receiving palliative radiotherapy for spinal metastases often have severe pain, which may impair positional stability during treatment. We evaluated whether pain severity is associated with setup error, and estimated setup margins stratified by spinal level and immobilization method.

Materials and methods: This secondary analysis used data from a prospective cohort (UMIN000044984) of patients who underwent three-dimensional conformal spinal radiotherapy at our institution. Only sites with pre-treatment CBCT and a recorded baseline numerical rating scale (NRS) pain score were included (376 sites, 270 patients). The three-dimensional vector setup error was calculated as √(SI2 + LR2 + AP2), where SI, LR, and AP denote the superior–inferior, left–right, and anterior–posterior translational errors. Pain was categorized as mild (NRS 0–4), moderate (5–6), or severe (7–10). Associations with setup error were assessed by the Kruskal–Wallis test and Spearman correlation. Setup margins were estimated using both |mean| + 2SD and |mean| + 3SD criteria per direction, stratified by spinal level and immobilization method.

Results: Median 3D vector setup error was 0.52 cm (IQR, 0.36–0.75). Setup error did not differ across pain groups (Kruskal–Wallis P = 0.134; Spearman r = 0.088, P = 0.089). Spinal level was the main associated factor: cervical treatments (thermoplastic mask) had lower median error than thoracolumbar/sacral (TLS) treatments without immobilization (0.41 vs. 0.54 cm, P = 0.004). Estimated margins were approximately 1.0 cm (cervical) and 1.5 cm (TLS).

Conclusions: Baseline pain severity was not associated with setup error in palliative spinal radiotherapy. Spinal level, which determined the immobilization method, was the factor most strongly associated with setup error. The proposed margins may serve as practical planning references, in settings without pre-treatment image guidance based on skin-mark alignment.

Related

  1. EP09.29 Image-guided intraoperative radiotherapy for resectable brain metastases: Prospective evaluation of dosimetric accuracy and clinical outcomes
    C S Dejonckheere, G R Sarria, M Grimmer +14
    Neuro-OncologyPeer-reviewedPublisher termsFull textOncologyPMC
  2. OS05.4.A Discordance between clinician- and patient-reported outcomes during radiotherapy for brain metastases: The prospective NeuroPRO study
    C S Dejonckheere, Y L Layer, A Potthoff +16
    Neuro-OncologyPeer-reviewedPublisher termsFull textOncologyPMC
  3. P06.16.B Consensus-based white matter tract reconstruction from diffusion MRI acquired in radiotherapy treatment position in primary and secondary brain tumors: interim analysis of a prospective cohort
    S Bockel, M Oukarrou, A Stan +10
    Neuro-OncologyPeer-reviewedPublisher termsFull textMedical imaging & radiologyPMC
  4. Preoperative Stereotactic Radiotherapy for Spinal Metastases: Study Protocol for a Prospective Exploratory Interventional Trial
    Carla Marie Zwerenz, Thomas Asendorf, Bilal Younes +15
    Neurosurgery practicePeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMCEurope PMCPMC
  5. Incremental Value of Radiation Dose for Prognostic Stratification Beyond Performance Status in Palliative Radiation Therapy for Bone Metastases
    Advances in radiation oncologyPeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{aoyama2026pain,
  title = {{Pain severity and setup error in palliative radiotherapy for spinal metastases: A secondary analysis of a prospective cohort☆}},
  author = {Takahiro Aoyama and Yutaro Koide and Tomoki Kitagawa and Ryoma Tomoda and Shingo Hashimoto and Hiroyuki Tachibana and Takeshi Kodaira},
  journal = {Technical Innovations \& Patient Support in Radiation Oncology},
  year = {2026},
  month = nov,
  doi = {10.1016/j.tipsro.2026.100452},
  url = {https://doi.org/10.1016/j.tipsro.2026.100452},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Pain severity and setup error in palliative radiotherapy for spinal metastases: A secondary analysis of a prospective cohort☆
AU  - Takahiro Aoyama
AU  - Yutaro Koide
AU  - Tomoki Kitagawa
AU  - Ryoma Tomoda
AU  - Shingo Hashimoto
AU  - Hiroyuki Tachibana
AU  - Takeshi Kodaira
PY  - 2026
DA  - 2026/11/04
JO  - Technical Innovations & Patient Support in Radiation Oncology
DO  - 10.1016/j.tipsro.2026.100452
UR  - https://doi.org/10.1016/j.tipsro.2026.100452
AB  - Background and purpose: Patients receiving palliative radiotherapy for spinal metastases often have severe pain, which may impair positional stability during treatment. We evaluated whether pain severity is associated with setup error, and estimated setup margins stratified by spinal level and immobilization method.  Materials and methods: This secondary analysis used data from a prospective cohort (UMIN000044984) of patients who underwent three-dimensional conformal spinal radiotherapy at our institution. Only sites with pre-treatment CBCT and a recorded baseline numerical rating scale (NRS) pain score were included (376 sites, 270 patients). The three-dimensional vector setup error was calculated as √(SI2 + LR2 + AP2), where SI, LR, and AP denote the superior–inferior, left–right, and anterior–posterior translational errors. Pain was categorized as mild (NRS 0–4), moderate (5–6), or severe (7–10). Associations with setup error were assessed by the Kruskal–Wallis test and Spearman correlation. Setup margins were estimated using both |mean| + 2SD and |mean| + 3SD criteria per direction, stratified by spinal level and immobilization method.  Results: Median 3D vector setup error was 0.52 cm (IQR, 0.36–0.75). Setup error did not differ across pain groups (Kruskal–Wallis P = 0.134; Spearman r = 0.088, P = 0.089). Spinal level was the main associated factor: cervical treatments (thermoplastic mask) had lower median error than thoracolumbar/sacral (TLS) treatments without immobilization (0.41 vs. 0.54 cm, P = 0.004). Estimated margins were approximately 1.0 cm (cervical) and 1.5 cm (TLS).  Conclusions: Baseline pain severity was not associated with setup error in palliative spinal radiotherapy. Spinal level, which determined the immobilization method, was the factor most strongly associated with setup error. The proposed margins may serve as practical planning references, in settings without pre-treatment image guidance based on skin-mark alignment.
SN  - 2405-6324
ER  -