Elasticity per Thickness Index for Breast Sonoelastography: Quantitative Analysis of Implant- and Clinically Related Peri-Implant Capsular Formation
4 affiliations
- 1Student Scientific Society, Poznan University of Medical Sciences, 10 Fredry St., 61-701 Poznan, Poland
- 2Zlotowska Plastic Surgery Clinic, 63 Złotowska St., 60-184 Poznan, Poland
- 3Department of Practical Midwifery Education, Poznan University of Medical Sciences, 33 Polna St, 60-535 Poznan, Poland
- 4Department of Mother’s and Child’s Health and Minimally Invasive Gynecologic Surgery, Poznan University of Medical Sciences, 33 Polna St., 60-535 Poznan, Poland
Abstract
Background: Peri-implant capsular formation remains a multifactorial process influenced by implant characteristics and patient-specific tissue responses. Ultrasound with shear-wave elastography offers evaluation of the biomechanical properties of both the capsule and surrounding breast tissues. Elastographic assessment does not distinguish intrinsic stiffness from the amount of fibrotic tissue. We introduced the Elasticity per Thickness Index (ETI) as an exploratory measure of capsular stiffness related to capsule thickness. Methods: This prospective study assessed peri-implant capsules and adjacent breast tissue compartments using B-mode ultrasound and shear-wave elastography over more than two years of follow-up. Capsular stiffness, thickness, and the exploratory Elasticity per Thickness Index (ETI; kPa/mm) were compared across implant characteristics, and their associations with clinical variables were analyzed. Results: Significant postoperative increases in stiffness were found across multiple native tissue compartments. Breast tissues remained on average stiffer than preoperatively throughout follow-up. Implant type or shape (F and M series, L3, MP EU, HP EU; anatomical vs. round) showed no association with stiffness changes, although round implants tended to yield higher fascial stiffness (p = 0.080). The ETI was independent of implant shape (p = 0.430). Higher-profile implants showed a nominally higher ETI than medium-profile implants (39.1 ± 13.4 vs. 31.9 ± 13.4 kPa/mm; unadjusted p = 0.050), which should be interpreted as an exploratory finding. The ETI was not significantly associated with implant profile after accounting for bilateral clustering (p = 0.455). Capsular stiffness was inversely associated with time from surgery to assessment (Rs = −0.329, p = 0.013), although this cross-sectional association does not demonstrate longitudinal softening. Conclusions: At the postoperative assessment, the peri-implant capsule showed a mean stiffness of 15.52 ± 3.81 kPa. The ETI may provide a complementary thickness-related description of capsular stiffness, although its reliability and clinical relevance require further validation. No robust association between implant profile and the ETI was identified after accounting for bilateral clustering.
Related
- Can Esophageal Stiffness and Thickness Measurement by Transcervical Sonoelastography Predict Reflux Esophagitis?
- Ultrasonographic evaluation of the association between gonial appositional bone changes and masseter muscle thickness and elasticity in bruxism
- Quantitative analysis of venous wall elasticity in arm arteriovenous fistulas using shear wave elastography: A prospective cross-sectional study
- EP05.22 Quantitative AI-based digital pathology classifier identifies clinically relevant tumor type-associated histologic patterns in adult-type diffuse gliomas
- Insulinoma in Type 2 Diabetes Mellitus Becoming Clinically Evident in the Setting of Acute Kidney Injury: A Case with a Postoperative Deterioration of the Glucose Metabolism and a Quantitative Islet Cell Analysis
BibTeX
@article{rzymska2026elasticity,
title = {{Elasticity per Thickness Index for Breast Sonoelastography: Quantitative Analysis of Implant- and Clinically Related Peri-Implant Capsular Formation}},
author = {Alicja Rzymska and Mikołaj Kubasik and Beata Pięta and Paweł Rzymski},
journal = {Diagnostics},
year = {2026},
month = oct,
doi = {10.3390/diagnostics16213515},
url = {https://doi.org/10.3390/diagnostics16213515},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Elasticity per Thickness Index for Breast Sonoelastography: Quantitative Analysis of Implant- and Clinically Related Peri-Implant Capsular Formation
AU - Alicja Rzymska
AU - Mikołaj Kubasik
AU - Beata Pięta
AU - Paweł Rzymski
PY - 2026
DA - 2026/10/27
JO - Diagnostics
DO - 10.3390/diagnostics16213515
UR - https://doi.org/10.3390/diagnostics16213515
AB - Background: Peri-implant capsular formation remains a multifactorial process influenced by implant characteristics and patient-specific tissue responses. Ultrasound with shear-wave elastography offers evaluation of the biomechanical properties of both the capsule and surrounding breast tissues. Elastographic assessment does not distinguish intrinsic stiffness from the amount of fibrotic tissue. We introduced the Elasticity per Thickness Index (ETI) as an exploratory measure of capsular stiffness related to capsule thickness. Methods: This prospective study assessed peri-implant capsules and adjacent breast tissue compartments using B-mode ultrasound and shear-wave elastography over more than two years of follow-up. Capsular stiffness, thickness, and the exploratory Elasticity per Thickness Index (ETI; kPa/mm) were compared across implant characteristics, and their associations with clinical variables were analyzed. Results: Significant postoperative increases in stiffness were found across multiple native tissue compartments. Breast tissues remained on average stiffer than preoperatively throughout follow-up. Implant type or shape (F and M series, L3, MP EU, HP EU; anatomical vs. round) showed no association with stiffness changes, although round implants tended to yield higher fascial stiffness (p = 0.080). The ETI was independent of implant shape (p = 0.430). Higher-profile implants showed a nominally higher ETI than medium-profile implants (39.1 ± 13.4 vs. 31.9 ± 13.4 kPa/mm; unadjusted p = 0.050), which should be interpreted as an exploratory finding. The ETI was not significantly associated with implant profile after accounting for bilateral clustering (p = 0.455). Capsular stiffness was inversely associated with time from surgery to assessment (Rs = −0.329, p = 0.013), although this cross-sectional association does not demonstrate longitudinal softening. Conclusions: At the postoperative assessment, the peri-implant capsule showed a mean stiffness of 15.52 ± 3.81 kPa. The ETI may provide a complementary thickness-related description of capsular stiffness, although its reliability and clinical relevance require further validation. No robust association between implant profile and the ETI was identified after accounting for bilateral clustering.
SN - 2075-4418
ER -