Skip to content
DraconiticResearch
Search Sources API
201,818 studies31 sourcesUpdated 12 min ago
Peer-reviewedCC BY-NC-NDPrecision radiation oncology

Evaluation of Concordance between Radiation Therapists and Medical Physicists in MR-Guided Online Adaptive Planning.

6 affiliations
  1. 1Department of GI Radiation Oncology The University of Texas MD Anderson Cancer Center Houston Texas USA.
  2. 2Department of Radiation Physics The University of Texas MD Anderson Cancer Center Houston Texas USA.
  3. 3Department of Radiation Oncology Therapy The University of Texas MD Anderson Cancer Center Houston Texas USA.
  4. 4Department of Biostatistics The University of Texas MD Anderson Cancer Center Houston Texas USA.
  5. 5Department of GU Radiation Oncology The University of Texas MD Anderson Cancer Center Houston Texas USA.
  6. 6Department of Radiation Oncology The University of Texas MD Anderson Cancer Center Houston Texas USA.

Abstract

Purpose

Magnetic resonance (MR) -guided online adaptive radiotherapy requires skill in online adaptive treatment planning. The aim of this study was to demonstrate that radiation therapists, with appropriate training, can consistently produce high-quality adaptive plans concordant with those created by medical physicists for treatment on a 1.5 Tesla MR-Linac (MRL).Methods

We evaluated plans generated by two experienced MRL radiation therapists and two MR-Linac medical physicists using an adapt-to-position (ATP) workflow to treat 10 patients with head and neck cancer; this workflow includes an iso-center shift and plan re-optimization to account for setup discrepancy between simulation and treatment. For each adaptive session, CT-MR images were fused and isocenter translational shifts recorded. Differences among the three roles (Therapist, Physicist 1, Physicist 2) were assessed by repeated-measures analysis of variance (RM-ANOVA) and Bonferroni-corrected post-hoc paired t tests, reported as secondary, exploratory analyses. Agreement on shifts and dosimetric endpoints was quantified with Lin's concordance correlation coefficient (CCC), with bias-corrected and accelerated bootstrap 95% confidence intervals (CIs), as the primary analysis.Results

No significant differences were observed among roles for X- or Y-axis shifts (p = 0.804 and p = 0.950). A statistically significant difference was observed for Z-axis shifts (p = 0.005), driven by Therapist versus Physicist 1 (Bonferroni-adjusted p = 0.015; mean paired difference 0.10 cm, 95% CI 0.04-0.17 cm), a systematic difference of approximately 1 mm that is small relative to clinical planning margins. CCC point estimates were 0.866-0.970 for translational shifts and 0.972-0.997 for target coverage and maximum dose, with no point estimate in the poor-agreement range (CCC < 0.80). Bootstrap 95% CIs were wide for the shifts, as expected at n = 10, but therapist-physicist agreement was comparable to physicist-physicist agreement for every endpoint, and CI lower bounds for the dosimetric endpoints were ≥0.75 (maximum dose ≥0.97).Conclusion

Our results showed good concordance between adaptive plans created by radiation therapists and medical physicists in the ATP workflow for head and neck cancer, suggesting that appropriately trained therapists can produce high-quality adaptive plans in this specific context. These conclusions are limited to the ATP workflow and to head and neck cancer; extension to other sites or to the adapt-to-shape (ATS) workflow requires independent investigation.

Related

  1. Corrections to Hawking radiation from asteroid-mass primordial black holes: analytic and numerical evaluation of the stochastic charge effect
    Gabriel Vasquez, Bowen Chen, Cara Nel +3
    arXivPreprintarXiv licenceFull textCosmologyGravitation & general relativityarXiv
  2. Development and clinical evaluation of fluorescent tattoo system for radiation therapy
    Chang Heon Choi, Hong-Gyun Wu, Hak Jae Kim +6
    Scientific ReportsPeer-reviewedCC BYFull textApplied physics & instrumentationDOAJ
  3. Preliminary Feasibility and Dosimetric Evaluation of Retroperitoneal Hydrogel Spacer Placement for Stereotactic Body Radiation Therapy: A Cadaveric Study
    Shin Tanabe, Kotaro Yoshio, Takaaki Komiyama +9
    Advances in Radiation OncologyPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationPMC
  4. Implementation and preliminary evaluation of a practical digital workflow for routine laser-radiation field coincidence quality assurance on the CyberKnife M6.
    Linzheng Hu, Yongkang Zhao, Chunling Zheng +6
    Precision radiation oncologyPeer-reviewedCC BYFull textApplied physics & instrumentationEurope PMC
  5. Self-adaptive transcranial ultrasound imaging using an effective skull model: experimental evaluation on a human skull at 3.15 MHz
    Damien Kuntz, Anthony Novell, Quentin Grimal +2
    Acta AcusticaPeer-reviewedCC BY 4.0Full textBiological & medical physicsHAL
BibTeX
@article{birring2026evaluation,
  title = {{Evaluation of Concordance between Radiation Therapists and Medical Physicists in MR-Guided Online Adaptive Planning.}},
  author = {Eva Birring and Yao Zhao and Tze Yee Lim and Mustefa Mohammedsaid and Neil Hughes and Cameron Tharp and JaRhonda Tealer and Ruitao Lin and Comron Hassanzadeh and C David Fuller and Jinzhong Yang},
  journal = {Precision radiation oncology},
  year = {2026},
  month = oct,
  doi = {10.1002/pro6.70105},
  url = {https://europepmc.org/article/MED/42927081},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Evaluation of Concordance between Radiation Therapists and Medical Physicists in MR-Guided Online Adaptive Planning.
AU  - Eva Birring
AU  - Yao Zhao
AU  - Tze Yee Lim
AU  - Mustefa Mohammedsaid
AU  - Neil Hughes
AU  - Cameron Tharp
AU  - JaRhonda Tealer
AU  - Ruitao Lin
AU  - Comron Hassanzadeh
AU  - C David Fuller
AU  - Jinzhong Yang
PY  - 2026
DA  - 2026/10/24
JO  - Precision radiation oncology
DO  - 10.1002/pro6.70105
UR  - https://europepmc.org/article/MED/42927081
AB  - Purpose  Magnetic resonance (MR) -guided online adaptive radiotherapy requires skill in online adaptive treatment planning. The aim of this study was to demonstrate that radiation therapists, with appropriate training, can consistently produce high-quality adaptive plans concordant with those created by medical physicists for treatment on a 1.5 Tesla MR-Linac (MRL).Methods  We evaluated plans generated by two experienced MRL radiation therapists and two MR-Linac medical physicists using an adapt-to-position (ATP) workflow to treat 10 patients with head and neck cancer; this workflow includes an iso-center shift and plan re-optimization to account for setup discrepancy between simulation and treatment. For each adaptive session, CT-MR images were fused and isocenter translational shifts recorded. Differences among the three roles (Therapist, Physicist 1, Physicist 2) were assessed by repeated-measures analysis of variance (RM-ANOVA) and Bonferroni-corrected post-hoc paired t tests, reported as secondary, exploratory analyses. Agreement on shifts and dosimetric endpoints was quantified with Lin's concordance correlation coefficient (CCC), with bias-corrected and accelerated bootstrap 95% confidence intervals (CIs), as the primary analysis.Results  No significant differences were observed among roles for X- or Y-axis shifts (p = 0.804 and p = 0.950). A statistically significant difference was observed for Z-axis shifts (p = 0.005), driven by Therapist versus Physicist 1 (Bonferroni-adjusted p = 0.015; mean paired difference 0.10 cm, 95% CI 0.04-0.17 cm), a systematic difference of approximately 1 mm that is small relative to clinical planning margins. CCC point estimates were 0.866-0.970 for translational shifts and 0.972-0.997 for target coverage and maximum dose, with no point estimate in the poor-agreement range (CCC < 0.80). Bootstrap 95% CIs were wide for the shifts, as expected at n = 10, but therapist-physicist agreement was comparable to physicist-physicist agreement for every endpoint, and CI lower bounds for the dosimetric endpoints were ≥0.75 (maximum dose ≥0.97).Conclusion  Our results showed good concordance between adaptive plans created by radiation therapists and medical physicists in the ATP workflow for head and neck cancer, suggesting that appropriately trained therapists can produce high-quality adaptive plans in this specific context. These conclusions are limited to the ATP workflow and to head and neck cancer; extension to other sites or to the adapt-to-shape (ATS) workflow requires independent investigation.
SN  - 2398-7324
ER  -