Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 1 h ago
Peer-reviewedCC BYScientific Reports

Domain-independent PPG signal quality assessment framework via representation learning

  1. 1Wearable Technologies Lab, Department of Electrical and Electronic Engineering, Imperial College London

Abstract

Photoplethysmography (PPG) is a widely used non-invasive sensing technique for monitoring cardiovascular and respiratory parameters, however, its measurements are highly susceptible to artifacts, which can degrade signal quality and, in turn, the accuracy of derived vital signs. Reliable PPG signal quality assessment (SQA) is therefore critical, yet existing SQA methods often rely on handcrafted features or ad-hoc thresholds and tend to be dataset-specific, limiting their generalizability across different sensor locations and users. To address these gaps, this paper proposes a novel SQA approach for PPG that is real-time compatible and sensor-location invariant. The method leverages deep representation learning by fine-tuning a pre-trained PPG transformer (PPG-PT) with a triplet loss to learn an embedding space where PPG segments are meaningfully partitioned based on their morphology. Signal quality is then quantified by computing each window’s embedding distance to a set of reference embeddings representing high-quality PPG segments, yielding a flexible reference-based quality score without requiring any model retraining when adapting to new devices or domains. The proposed framework was evaluated on three PPG datasets: the Complex System Laboratory (CSL) dataset providing finger PPG, the Wearable and Clinical Devices (WCS) for wrist PPG signals, and the Apnea and Artifacts (AA) dataset representing neck PPG signals, encompassing a wide range of artifact types and recording conditions. The model achieved strong agreement with expert annotations on the CSL dataset, with an F1-score of ≈ 90%. It also demonstrated robust generalization on the WCS wearable dataset: using a generalized reference set drawn from multiple subjects, the approach attained a high F1-score of about ≈ 95% on wrist PPG data, highlighting the method’s potential for population-level deployment. Performance on the AA neck PPG dataset was moderately acceptable with ≈ 70% F1-score, likely due to the complexity and varying executions of the different artifacts presented in the dataset. The proposed methodology provides a deep learning SQA framework capable of generalizing across different PPG sensor locations and devices.

Related

  1. An Explainable Disease-Aware Intelligent Histopathological Representation Learning Framework for Generalizable Breast Cancer Classification
    Faizan Ahmad, Irfanud Din, Khalil Khan
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Quality of Movement Assessment after ACL Reconstruction in Youth: A Clinical Framework to Guide Rehabilitation and Return-to-Sport Decision-Making
    International journal of sports physical therapyPeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
  3. Application of spectroscopic and multispectral imaging technologies on the assessment of ready-to-eat pineapple quality: A performance evaluation study of machine learning models generated from two commercial data analytics tools
    Evanthia Manthou, Sergio-Llaneza Lago, Evaggelos Dagres +5
    Computers and Electronics in AgriculturePeer-reviewedLicence not stated38 citedGeneral biologyGeneral chemistryHAL
  4. Constructing the Self Data Atlas ontology: a crisp-fuzzy ontology for quality of life representation in children with neurodevelopmental and learning disabilities
    R Sterling Snead
    Frontiers in Public HealthPeer-reviewedCC BY 4.0Epidemiology & public healthCrossref
  5. PedDx: An End-to-End Deep Learning Framework for Pediatric Posterior Fossa Tumor Diagnosis with Agentic AI-Enabled Independent External Evaluation
    A. Fathi Kazerooni, F. Batal, B. Vunnava +27
    medRxivPreprintCC BY-NCFull textObstetrics, gynaecology & paediatricsmedRxivPMC
BibTeX
@article{abdulsadig2026domainindependent,
  title = {{Domain-independent PPG signal quality assessment framework via representation learning}},
  author = {Rawan S. Abdulsadig and Esther Rodriguez-Villegas},
  journal = {Scientific Reports},
  year = {2026},
  month = jul,
  doi = {10.1038/s41598-026-58783-6},
  url = {https://doi.org/10.1038/s41598-026-58783-6},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Domain-independent PPG signal quality assessment framework via representation learning
AU  - Rawan S. Abdulsadig
AU  - Esther Rodriguez-Villegas
PY  - 2026
DA  - 2026/07/01
JO  - Scientific Reports
DO  - 10.1038/s41598-026-58783-6
UR  - https://doi.org/10.1038/s41598-026-58783-6
AB  - Photoplethysmography (PPG) is a widely used non-invasive sensing technique for monitoring cardiovascular and respiratory parameters, however, its measurements are highly susceptible to artifacts, which can degrade signal quality and, in turn, the accuracy of derived vital signs. Reliable PPG signal quality assessment (SQA) is therefore critical, yet existing SQA methods often rely on handcrafted features or ad-hoc thresholds and tend to be dataset-specific, limiting their generalizability across different sensor locations and users. To address these gaps, this paper proposes a novel SQA approach for PPG that is real-time compatible and sensor-location invariant. The method leverages deep representation learning by fine-tuning a pre-trained PPG transformer (PPG-PT) with a triplet loss to learn an embedding space where PPG segments are meaningfully partitioned based on their morphology. Signal quality is then quantified by computing each window’s embedding distance to a set of reference embeddings representing high-quality PPG segments, yielding a flexible reference-based quality score without requiring any model retraining when adapting to new devices or domains. The proposed framework was evaluated on three PPG datasets: the Complex System Laboratory (CSL) dataset providing finger PPG, the Wearable and Clinical Devices (WCS) for wrist PPG signals, and the Apnea and Artifacts (AA) dataset representing neck PPG signals, encompassing a wide range of artifact types and recording conditions. The model achieved strong agreement with expert annotations on the CSL dataset, with an F1-score of ≈ 90%. It also demonstrated robust generalization on the WCS wearable dataset: using a generalized reference set drawn from multiple subjects, the approach attained a high F1-score of about ≈ 95% on wrist PPG data, highlighting the method’s potential for population-level deployment. Performance on the AA neck PPG dataset was moderately acceptable with ≈ 70% F1-score, likely due to the complexity and varying executions of the different artifacts presented in the dataset. The proposed methodology provides a deep learning SQA framework capable of generalizing across different PPG sensor locations and devices.
SN  - 2045-2322
ER  -