Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 4 min ago
Peer-reviewedCC BY 4.0The International Journal of Cardiovascular Imaging

Deep-learning denoising for ultrahigh-resolution photon-counting detector CT: phantom and in vivo evaluation of non-calcified coronary plaques

2 more authors
13 affiliations
  1. 1Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425 USA
  2. 2Department of Radiology, LMU University Hospital, LMU Munich, 15 Marchioninistraße, 81377 Munich, Germany
  3. 3Department of Diagnostic and Interventional Radiology, Medical Center, Faculty of Medicine, University of Freiburg, University of Freiburg, 55 Hugstetter Straße, 79106 Freiburg, Germany
  4. 4Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg-University, 1 Langenbeckstraße, 55131 Mainz, Germany
  5. 5UNICA Radiology, MRI unit Hospital da Luz Lisboa, Católica Medical School, 100 Av. Lusíada, Cardiovascular, Lisboa, 1500-650 CT Portugal
  6. 6Department of Medicine, UC San Diego School of Medicine, 9500 Gilman Dr, La Jolla, 92093 CA USA
  7. 7Department of Cardiovascular Division, UC San Diego School of Medicine, 9500 Gilman Dr, La Jolla, 92093 CA USA
  8. 8Department of Radiology, UC San Diego School of Medicine, 9500 Gilman Dr, La Jolla, 92093 CA USA
  9. 9Department of Bioengineering, UC San Diego School of Medicine, 9500 Gilman Dr, La Jolla, 92093 CA USA
  10. 10Department of Cardiology and Radiology, Scripps Clinic, 9888 Genesee Ave, La Jolla, 92037 CA USA
  11. 11Department of Radiology, Medical Imaging Center, Semmelweis University, 2 Koranyi Sandor street, Budapest, 1083 Hungary
  12. 12Heart and Vascular Centre, Semmelweis University, 68 Varosmajor street, Budapest, 1122 Hungary
  13. 13German Centre for Cardiovascular Research, Partner Site Rhine-Main, 1 Langenbeckstraße, 55131 Mainz, Germany

Abstract

To assess the value of convolutional neural network (CNN)-based denoising for the evaluation of non-calcified coronary plaques on ultrahigh-resolution (UHR) photon-counting detector (PCD) coronary CT angiography (CCTA). A dynamic phantom containing lipid-rich and fibrotic plaques with 50%-diameter stenosis (PDS) was scanned on PCD-CT under varying conditions. For in-vivo imaging, consecutive patients with non-calcified coronary plaques (NCPs) who underwent CCTA with PCD-CT were included. Image series were reconstructed using a sharp vascular kernel (Bv64) with slice thicknesses of 0.2 mm/0.4 mm, quantum iterative reconstruction (QIR) levels 3/4, and with/without CNN denoising. Phantom-based line-profile analysis yielded edge-width at half maximum (EWHM) and 10–90% rise distance as sharpness metrics. Plaque contrast-to-noise ratio (CNR) and PDS were assessed in the phantom and in patients. Two readers evaluated subjective image quality (noise, diagnostic confidence) using a four-point Likert scale. Pairwise comparisons were performed using a Bonferroni-corrected p < 0.002 for significance. Fifty-five patients (median age 74 [66.5–78] years; 19 women) with 97 NCPs were included. Phantom-based sharpness metrics remained unchanged after denoising (all pairwise p > 0.051). CNN denoising increased plaque CNR consistently in the phantom (fibrotic: 0.80–1.64 to 0.92–2.06; lipid-rich: 0.21–0.34 to 0.35–0.46) and in vivo (0.99–2.07 to 1.37–2.92, all pairwise p < 0.001). Denoising did not alter PDS values in phantom or in vivo plaques (all pairwise p > 0.006). Subjective image noise and diagnostic confidence improved across all reconstructions (all pairwise p < 0.001). CNN-based denoising of UHR PCD-CT improves image quality of non-calcified coronary plaques, while preserving sharpness and quantitative stenosis metrics.

Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1007/s10554-026-03774-x.

Related

  1. Deep learning denoising and deep learning–augmented contrast enhancement improve ultra-high-resolution photon-counting-detector CCTA image quality
    Sebastian Steinmetz, Anton Kilburg, Antoine P Sanner +9
    European Radiology ExperimentalPeer-reviewedCC BY 4.0Full textMedical imaging & radiologyPMC
  2. Deep Learning Optimizes the Diagnostic Performance of Coronary Computed Tomography Angiography in Heavily Calcified Coronary Plaques: A Chinese Multicenter Study
    Chunyan Shi, Chengjin Yu, Bin Zhang +10
    Reviews in cardiovascular medicinePeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  3. Evaluation of Delphi high-resolution computed tomography phenotype classification for treatment-naïve patients with pulmonary sarcoidosis
    Ce Wang, Sijia Guo, Shi Shu +6
    Quantitative imaging in medicine and surgeryPeer-reviewedCC BY-NC-NDFull textMedical imaging & radiologyEurope PMC
  4. Handheld, quantitative phase imaging probe for skin evaluation at subcellular resolution in vivo, in real-time, and in 3D
    Srinidhi Bharadwaj, Zhe Guang, Lukas A Clark +10
    medRxivPreprintAll rights reservedFull textGeneral medicinemedRxivPMC
  5. Evaluation of rupture risk of pediatric intracranial aneurysm using high-resolution magnetic resonance imaging techniques: a case report.
    Xin Feng, Lele Dai, Wenxin Chen +7
    BMC neurologyPeer-reviewedCC BYFull textNeurologyEurope PMCPMC
BibTeX
@article{hyska2026deeplearning,
  title = {{Deep-learning denoising for ultrahigh-resolution photon-counting detector CT: phantom and in vivo evaluation of non-calcified coronary plaques}},
  author = {Sardi Hyska and Muhammad Taha Hagar and José Osoria-Velasquez and Nicola Fink and Jens Ricke and Moritz C. Halfmann and Hugo Marques and Elliot McVeigh and George Wesbey and Pál Maurovich-Horvat and Bálint Szilveszter and Tilman Emrich and Akos Varga-Szemes and Milan Vecsey-Nagy},
  journal = {The International Journal of Cardiovascular Imaging},
  year = {2026},
  month = jul,
  doi = {10.1007/s10554-026-03774-x},
  url = {https://doi.org/10.1007/s10554-026-03774-x},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Deep-learning denoising for ultrahigh-resolution photon-counting detector CT: phantom and in vivo evaluation of non-calcified coronary plaques
AU  - Sardi Hyska
AU  - Muhammad Taha Hagar
AU  - José Osoria-Velasquez
AU  - Nicola Fink
AU  - Jens Ricke
AU  - Moritz C. Halfmann
AU  - Hugo Marques
AU  - Elliot McVeigh
AU  - George Wesbey
AU  - Pál Maurovich-Horvat
AU  - Bálint Szilveszter
AU  - Tilman Emrich
AU  - Akos Varga-Szemes
AU  - Milan Vecsey-Nagy
PY  - 2026
DA  - 2026/07/10
JO  - The International Journal of Cardiovascular Imaging
DO  - 10.1007/s10554-026-03774-x
UR  - https://doi.org/10.1007/s10554-026-03774-x
AB  - To assess the value of convolutional neural network (CNN)-based denoising for the evaluation of non-calcified coronary plaques on ultrahigh-resolution (UHR) photon-counting detector (PCD) coronary CT angiography (CCTA). A dynamic phantom containing lipid-rich and fibrotic plaques with 50%-diameter stenosis (PDS) was scanned on PCD-CT under varying conditions. For in-vivo imaging, consecutive patients with non-calcified coronary plaques (NCPs) who underwent CCTA with PCD-CT were included. Image series were reconstructed using a sharp vascular kernel (Bv64) with slice thicknesses of 0.2 mm/0.4 mm, quantum iterative reconstruction (QIR) levels 3/4, and with/without CNN denoising. Phantom-based line-profile analysis yielded edge-width at half maximum (EWHM) and 10–90% rise distance as sharpness metrics. Plaque contrast-to-noise ratio (CNR) and PDS were assessed in the phantom and in patients. Two readers evaluated subjective image quality (noise, diagnostic confidence) using a four-point Likert scale. Pairwise comparisons were performed using a Bonferroni-corrected p < 0.002 for significance. Fifty-five patients (median age 74 [66.5–78] years; 19 women) with 97 NCPs were included. Phantom-based sharpness metrics remained unchanged after denoising (all pairwise p > 0.051). CNN denoising increased plaque CNR consistently in the phantom (fibrotic: 0.80–1.64 to 0.92–2.06; lipid-rich: 0.21–0.34 to 0.35–0.46) and in vivo (0.99–2.07 to 1.37–2.92, all pairwise p < 0.001). Denoising did not alter PDS values in phantom or in vivo plaques (all pairwise p > 0.006). Subjective image noise and diagnostic confidence improved across all reconstructions (all pairwise p < 0.001). CNN-based denoising of UHR PCD-CT improves image quality of non-calcified coronary plaques, while preserving sharpness and quantitative stenosis metrics.  Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1007/s10554-026-03774-x.
SN  - 1569-5794
SN  - 1875-8312
ER  -