Preliminary Feasibility of Contrast Sensitivity Testing Using the IMO vifa Perimeter After Cataract Surgery.
- 1Oki Eye Center, Sojukai Medical Foundation, Tokyo, Japan.
- 2Department of Ophthalmology, Jikei University School of Medicine, Tokyo, Japan.
Abstract
Purpose
To evaluate the feasibility of contrast sensitivity (CS) testing using a head-mounted binocular perimeter (IMO vifa) and to describe postoperative CS in eyes implanted with three types of intraocular lenses (IOLs).Patients and methods
This retrospective single-center study included 102 eyes of 71 patients who underwent uncomplicated cataract surgery with implantation of a segmented refractive IOL (Lentis Comfort [LC], 38 eyes), an enhanced monofocal IOL (Tecnis Eyhance DIB00V [DIB], 33 eyes), or a standard monofocal IOL (Tecnis DCB00V [DCB], 31 eyes). CS was measured in each eye with both eyes open under photopic room lighting 1 month postoperatively, and the area under the log CS function (AULCSF) was calculated. Groups were compared using age-adjusted linear regression accounting for inter-eye correlation.Results
Testing required approximately 5 min per patient. Mean AULCSF was 1.35 ± 0.27, 1.19 ± 0.26, and 1.30 ± 0.24 in the LC, DIB, and DCB groups, respectively. No statistically significant difference was detected among the groups after age adjustment (p = 0.304). Compared with DCB, the adjusted differences were 0.017 (95% CI -0.113 to 0.148) for LC and -0.082 (95% CI -0.213 to 0.049) for DIB.Conclusion
CS testing with the IMO vifa was feasible at routine postoperative visits under ambient room lighting. Further prospective studies are needed to assess its repeatability and agreement with established CS tests.
Related
- Anterior Capsule Contrast and Capsulorhexis Geometry Across Visualization Systems in Cataract Surgery: An Exploratory Image-Based Comparison
- 5T Non-Contrast One-Stop MRA for Thoracic Aorta and Coronary Arteries: A Prospective Feasibility Study in Healthy Volunteers
- Visualization of the Eustachian Tube Cartilage on Delayed Contrast-enhanced 3D-MR Imaging: A Preliminary Comparison between Ionic and Non-ionic Gadolinium-based Contrast Agents
- Feasibility, Safety, and Preliminary Efficacy of Partnered Rhythmic Rehabilitation in Prodromal Alzheimer's Disease: A 12-Month Pilot Randomized Controlled Trial
- Acceptability, Feasibility, and Preliminary Efficacy of a Digital Cognitive Intervention for Post-Acute Sequelae of SARS-CoV-2 Infection (PASC) in Older Adults
BibTeX
@article{oki2026preliminary,
title = {{Preliminary Feasibility of Contrast Sensitivity Testing Using the IMO vifa Perimeter After Cataract Surgery.}},
author = {Tetsutaro Oki and Koji Komatsu and Yuri Shinohe and Yoshiaki Kabata and Kotaro Oki and Tadashi Nakano},
journal = {Clinical ophthalmology (Auckland, N.Z.)},
year = {2026},
month = oct,
doi = {10.2147/opth.s644954},
url = {https://europepmc.org/article/MED/42903087},
note = {CC BY-NC},
}
RIS
TY - JOUR
TI - Preliminary Feasibility of Contrast Sensitivity Testing Using the IMO vifa Perimeter After Cataract Surgery.
AU - Tetsutaro Oki
AU - Koji Komatsu
AU - Yuri Shinohe
AU - Yoshiaki Kabata
AU - Kotaro Oki
AU - Tadashi Nakano
PY - 2026
DA - 2026/10/15
JO - Clinical ophthalmology (Auckland, N.Z.)
DO - 10.2147/opth.s644954
UR - https://europepmc.org/article/MED/42903087
AB - Purpose To evaluate the feasibility of contrast sensitivity (CS) testing using a head-mounted binocular perimeter (IMO vifa) and to describe postoperative CS in eyes implanted with three types of intraocular lenses (IOLs).Patients and methods This retrospective single-center study included 102 eyes of 71 patients who underwent uncomplicated cataract surgery with implantation of a segmented refractive IOL (Lentis Comfort [LC], 38 eyes), an enhanced monofocal IOL (Tecnis Eyhance DIB00V [DIB], 33 eyes), or a standard monofocal IOL (Tecnis DCB00V [DCB], 31 eyes). CS was measured in each eye with both eyes open under photopic room lighting 1 month postoperatively, and the area under the log CS function (AULCSF) was calculated. Groups were compared using age-adjusted linear regression accounting for inter-eye correlation.Results Testing required approximately 5 min per patient. Mean AULCSF was 1.35 ± 0.27, 1.19 ± 0.26, and 1.30 ± 0.24 in the LC, DIB, and DCB groups, respectively. No statistically significant difference was detected among the groups after age adjustment (p = 0.304). Compared with DCB, the adjusted differences were 0.017 (95% CI -0.113 to 0.148) for LC and -0.082 (95% CI -0.213 to 0.049) for DIB.Conclusion CS testing with the IMO vifa was feasible at routine postoperative visits under ambient room lighting. Further prospective studies are needed to assess its repeatability and agreement with established CS tests.
SN - 1177-5467