The influence of surface functionalization and signal transduction on electrochemical aptamer-based sensors

Abstract

Electrochemical aptamer-based (E-AB) sensors are a major topic of research, yet their transition from laboratory proof-of-concept to robust real-life applications remains limited. This phenomenon can partly be explained by examining the fundamental physicochemical challenges at the bio-interface. This review provides a critical perspective on two decisive factors: interfacial functionalization and electrochemical interrogation. We argue that because E-AB performance is governed by electron transfer at the electrode-electrolyte boundary, the choice of immobilization chemistry is an important factor for analytical stability and sensitivity. Furthermore, we exemplify how different electrochemical techniques, ranging from square-wave voltammetry to impedimetric methods, impact electrode longevity and signal reliability. We believe the two aspects are the main contributing factors influencing the performance of E-AB sensors.

Related

  1. Charge-screening dominates signal transduction in electrochemical nucleic acid sensors for aminoglycosides
    S. Yee, G. Maddocks, H. T. Soh
    bioRxivPreprintCC BY-NCFull textSystems & synthetic biologybioRxiv
  2. Detection of Mercury Ions at ng/L Scale by Surface Plasmon Resonance (SPR) on DNA Aptamer Biochips
    Antoine Elie, Yann Niberon, Aurélien Bruyant +3
    Journal of Physical Chemistry CPeer-reviewedCC BY 4.0Full text8 citedSystems & synthetic biologyAnalytical chemistryHAL
  3. Influence of PEGylation and Surface Charge on Biodistribution of Shortwave Infrared Emitting Nanoparticles for In Vivo Bioimaging
    Lucie Haye, Maxime Henry, Véronique Josserand +7
    ACS Applied Nano MaterialsPeer-reviewedCC BY 4.0Full text1 citedSystems & synthetic biologyGeneral chemistryHAL
  4. Aptamer-Targeted PLGA Nanoparticles for Biofilm-Directed Intra-articular Antibiotic Delivery in Prosthetic Joint Infection
    Z. Eskandari, Y. Fan, K. Fujino +7
    bioRxivPreprintAll rights reservedFull textSystems & synthetic biologybioRxiv
  5. Adeno-associated virus serotype tropism and transduction in murine dorsal root ganglia following direct injection.
    M. ODonnell, A. Fontaine, J. Caldwell +1
    bioRxivPreprintAll rights reservedFull textNeurosciencebioRxiv
BibTeX
@article{lupoi2026influence,
  title = {{The influence of surface functionalization and signal transduction on electrochemical aptamer-based sensors}},
  author = {Teodora Lupoi and Yann R. Leroux and Florence Geneste},
  journal = {Current Opinion in Electrochemistry},
  year = {2026},
  month = oct,
  doi = {10.1016/j.coelec.2026.101933},
  url = {https://hal.science/hal-05741463v1},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - The influence of surface functionalization and signal transduction on electrochemical aptamer-based sensors
AU  - Teodora Lupoi
AU  - Yann R. Leroux
AU  - Florence Geneste
PY  - 2026
DA  - 2026/10/14
JO  - Current Opinion in Electrochemistry
DO  - 10.1016/j.coelec.2026.101933
UR  - https://hal.science/hal-05741463v1
AB  - Electrochemical aptamer-based (E-AB) sensors are a major topic of research, yet their transition from laboratory proof-of-concept to robust real-life applications remains limited. This phenomenon can partly be explained by examining the fundamental physicochemical challenges at the bio-interface. This review provides a critical perspective on two decisive factors: interfacial functionalization and electrochemical interrogation. We argue that because E-AB performance is governed by electron transfer at the electrode-electrolyte boundary, the choice of immobilization chemistry is an important factor for analytical stability and sensitivity. Furthermore, we exemplify how different electrochemical techniques, ranging from square-wave voltammetry to impedimetric methods, impact electrode longevity and signal reliability. We believe the two aspects are the main contributing factors influencing the performance of E-AB sensors.
SN  - 2451-9103
SN  - 2451-9103
ER  -