Frequency-Axis Calibration via Autler-Townes Splitting in an Electromagnetically Induced Transparency Feature

Abstract

Rydberg atom-based electrometry is a pivotal technology that enables radio-frequency (rf) field measurements traceable to the International System of Units. This is typically accomplished by converting the direct rf power measurement of classical probes to a frequency measurement referenced to two well-defined spectral features, a commercial wavemeter, or narrow cavity lines produced via clock disciplined electro-optic modulators, although there exist cases where none of these are available. In this article, we demonstrate that a known rf frequency scale can be used to infer a laser's frequency scan using Autler-Townes (AT) splitting. In other words, we show that frequency-axis calibration can be achieved using the avoided-crossing behavior of near-resonant rf radiation. The relative separation between AT-split features is measured as a function of an applied rf field's power and detuning from atomic resonance. These peak separations are then fit to a simple, two-level model using a weighted nonlinear least-squares regression analysis that utilizes three fitting parameters, one of which is the desired calibration factor. While we do not benchmark this method against an absolute frequency reference, we do show that this method is (1) consistent with calibration via known fine-structure separation to within approximately 1.11% or better, and (2) robust against substantial experimental deviation from the system's known rf power dependence.

Related

  1. Velocity-selection modified electromagnetically induced transparency
    Cheng-Tso Tai, Tian-Chen Wang, Xu-Dong Liu +6
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  2. Kinematic saturation of the electromagnetically-induced-transparency peak in thermal atomic vapors
    Sheng-Xian Xiao, Jing-Yi Mao, Tao Wang
    arXivPreprintarXiv licenceFull textAtomic, molecular & optical physicsarXiv
  3. Spin-Exchange-Controlled Nonclassical Light in Cavity Electromagnetically Induced Transparency
    Jing Tang, Junyu Su, Jie Chen +2
    arXivPreprintCC BY 4.0Full textQuantum physics & quantum informationarXiv
  4. 85Rb electromagnetically induced transparency and absorption on two collinear 5S1/2→5P1/2→5D3/2→ 25F5/2 three-photon cascade schemes
    Shuaijie Li, Alisher Duspayev, Georg Raithel
    arXivPreprintarXiv licenceFull textAtomic, molecular & optical physicsQuantum physics & quantum informationarXiv
  5. Semiclassical molecular dynamics simulations of electromagnetically induced transparency cooling of 2D and 3D ion crystals in a Penning trap
    John Zaris, Wes Johnson, Krishna Balaji Sogathur +5
    arXivPreprintarXiv licenceFull textAtomic, molecular & optical physicsQuantum physics & quantum informationarXiv
BibTeX
@misc{oliver2026frequencyaxis,
  title = {{Frequency-Axis Calibration via Autler-Townes Splitting in an Electromagnetically Induced Transparency Feature}},
  author = {Stone B. Oliver and Noah Schlossberger and Tate McDonald and Christopher L. Holloway and Nikunjkumar Prajapati},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.04175},
  eprint = {2610.04175},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.04175},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Frequency-Axis Calibration via Autler-Townes Splitting in an Electromagnetically Induced Transparency Feature
AU  - Stone B. Oliver
AU  - Noah Schlossberger
AU  - Tate McDonald
AU  - Christopher L. Holloway
AU  - Nikunjkumar Prajapati
PY  - 2026
DA  - 2026/10/03
PB  - arXiv
DO  - 10.48550/arxiv.2610.04175
UR  - https://arxiv.org/abs/2610.04175
AB  - Rydberg atom-based electrometry is a pivotal technology that enables radio-frequency (rf) field measurements traceable to the International System of Units. This is typically accomplished by converting the direct rf power measurement of classical probes to a frequency measurement referenced to two well-defined spectral features, a commercial wavemeter, or narrow cavity lines produced via clock disciplined electro-optic modulators, although there exist cases where none of these are available. In this article, we demonstrate that a known rf frequency scale can be used to infer a laser's frequency scan using Autler-Townes (AT) splitting. In other words, we show that frequency-axis calibration can be achieved using the avoided-crossing behavior of near-resonant rf radiation. The relative separation between AT-split features is measured as a function of an applied rf field's power and detuning from atomic resonance. These peak separations are then fit to a simple, two-level model using a weighted nonlinear least-squares regression analysis that utilizes three fitting parameters, one of which is the desired calibration factor. While we do not benchmark this method against an absolute frequency reference, we do show that this method is (1) consistent with calibration via known fine-structure separation to within approximately 1.11% or better, and (2) robust against substantial experimental deviation from the system's known rf power dependence.
ER  -