Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 25 min ago
Peer-reviewedCC BY-NCJournal of clinical hypertension (Greenwich, Conn.)

Evaluation of a Machine Learning-Based Preeclampsia Risk Prediction Model Using Structured EHR Data.

4 affiliations
  1. 1Department of Health Policy and Management, Indiana University Richard M. Fairbanks School of Public Health, Indianapolis, Indiana, USA.
  2. 2Department of Epidemiology and Biostatistics, Indiana University of Public Health, Bloomington, Indiana, USA.
  3. 3Department of Obstetrics and Gynecology, Indiana University School of Medicine, Indianapolis, Indiana, USA.
  4. 4Center for Biostatistics, Informatics, and Data Science, MedStar Health, Columbia, Maryland, USA.

Abstract

The purpose of this study was to develop and evaluate a parsimonious preeclampsia prediction model using routinely available clinical and demographic data from electronic health records (EHRs). We analyzed data obtained from a large tertiary healthcare system comprising 12 787 deliveries, including 1444 women with preeclampsia and 11 343 without. Predictive features included demographics, parity, vitals, diagnoses, encounters, labs, and social history. The dataset was partitioned into training (70%) and test (30%) sets. We evaluated multiple machine learning algorithms, including logistic regression, random forest, k-nearest neighbors, support vector machine, and extreme gradient boosting (XGBoost). Test set performance was assessed using accuracy, precision, recall, F1-score, and area under the receiver operating characteristic curve (AUC). To further examine different data source contribution, we evaluated the performance of the best-performing model using features from combinations of individual domains. XGBoost performed best (accuracy = 0.715, precision = 0.231, recall = 0.641, F1 = 0.340, AUC = 0.753.). Reduced feature sets showed comparable performance. Top combinations included: (a) parity, vital signs, and laboratories (AUC = 0.740; recall = 0.657); (b) diagnosis codes, vital signs, and laboratories (AUC = 0.740; recall = 0.678); and (c) diagnosis codes, vital signs, demographics, and laboratories (AUC = 0.738; recall = 0.633). Routinely collected EHR data can support prediction of preeclampsia with moderate discrimination and high recall. Comparable performance of reduced feature sets supports scalability and implementation in diverse settings. External validation and prospective studies are needed to support integration into clinical decision support systems, particularly in settings with incomplete prenatal data.

Related

  1. Machine-Learning Prediction of Pediatric Thyroid Nodule Malignancy Using Structured Nodule and Cervical Lymph-Node Ultrasonographic Features
    Jiaojiao Ding, Xiao Zhang, Yue Chang +5
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. EP17.19 Development and evaluation of a modern, personalised prognostic prediction model for overall survival in real-world patients with glioblastoma using machine-learning methods
    A Morozova, E Ford, G Critchley +3
    Neuro-OncologyPeer-reviewedPublisher termsFull textOncologyPMC
  3. Extracorporeal Membrane Oxygenation (ECMO) Prediction of Mortality and Integrated Complication with Infection Risk Assessment by Machine Learning: Structured Narrative Review.
    Banu Ayse Birlik, Oumayma Hamlaoui, Hakan Tozan +2
    Advances in respiratory medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Multicenter evaluation of AI-based intraocular lens formulas and interpretable machine learning for cataract refractive prediction
    Ning Yang, Jiancheng Mu, Yi Liu +6
    Scientific ReportsPeer-reviewedCC BY 4.0Full textGeneral medicineCrossref
  5. Experimental evaluation, machine learning prediction, and life cycle assessment of sustainable self compacting concrete incorporating limestone powder and calcined clay
    Siva Shanmukha Anjaneya Babu Padavala, Siva Avudaiappan, Sudheer Kumar Yantrapalli +3
    Scientific ReportsPeer-reviewedCC BYFull textGeneral medicineDOAJ
BibTeX
@article{inderstrodt2026evaluation,
  title = {{Evaluation of a Machine Learning-Based Preeclampsia Risk Prediction Model Using Structured EHR Data.}},
  author = {Jill Inderstrodt and Shubham Tamhane and Erin M Cleary and Nawar Shara and Ahmed Deyab and Prabhjeet Singh and Kedir Turi},
  journal = {Journal of clinical hypertension (Greenwich, Conn.)},
  year = {2026},
  month = nov,
  doi = {10.1111/jch.70385},
  url = {https://europepmc.org/article/MED/43075868},
  note = {CC BY-NC},
}
RIS
TY  - JOUR
TI  - Evaluation of a Machine Learning-Based Preeclampsia Risk Prediction Model Using Structured EHR Data.
AU  - Jill Inderstrodt
AU  - Shubham Tamhane
AU  - Erin M Cleary
AU  - Nawar Shara
AU  - Ahmed Deyab
AU  - Prabhjeet Singh
AU  - Kedir Turi
PY  - 2026
DA  - 2026/11/01
JO  - Journal of clinical hypertension (Greenwich, Conn.)
DO  - 10.1111/jch.70385
UR  - https://europepmc.org/article/MED/43075868
AB  - The purpose of this study was to develop and evaluate a parsimonious preeclampsia prediction model using routinely available clinical and demographic data from electronic health records (EHRs). We analyzed data obtained from a large tertiary healthcare system comprising 12 787 deliveries, including 1444 women with preeclampsia and 11 343 without. Predictive features included demographics, parity, vitals, diagnoses, encounters, labs, and social history. The dataset was partitioned into training (70%) and test (30%) sets. We evaluated multiple machine learning algorithms, including logistic regression, random forest, k-nearest neighbors, support vector machine, and extreme gradient boosting (XGBoost). Test set performance was assessed using accuracy, precision, recall, F1-score, and area under the receiver operating characteristic curve (AUC). To further examine different data source contribution, we evaluated the performance of the best-performing model using features from combinations of individual domains. XGBoost performed best (accuracy = 0.715, precision = 0.231, recall = 0.641, F1 = 0.340, AUC = 0.753.). Reduced feature sets showed comparable performance. Top combinations included: (a) parity, vital signs, and laboratories (AUC = 0.740; recall = 0.657); (b) diagnosis codes, vital signs, and laboratories (AUC = 0.740; recall = 0.678); and (c) diagnosis codes, vital signs, demographics, and laboratories (AUC = 0.738; recall = 0.633). Routinely collected EHR data can support prediction of preeclampsia with moderate discrimination and high recall. Comparable performance of reduced feature sets supports scalability and implementation in diverse settings. External validation and prospective studies are needed to support integration into clinical decision support systems, particularly in settings with incomplete prenatal data.
SN  - 1524-6175
SN  - 1751-7176
ER  -