Skip to content
DraconiticResearch
Search Sources API
194,226 studies31 sourcesUpdated 58 min ago
Peer-reviewedCC BYFrontiers in cardiovascular medicine

Case Report: Angiography-guided transvenous single-chamber pacemaker implantation in mirror-image dextrocardia with congenitally corrected transposition of the great arteries.

  1. 1Jiujiang City Key Laboratory of Cell Therapy, Department of Cardiovascular Medicine, The First Hospital of Jiujiang City, Jiujiang, China.
  2. 2Department of Cardiovascular Medicine, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.

Abstract

Background

Mirror-image dextrocardia with situs inversus is uncommon. Transvenous permanent pacemaker implantation is technically demanding when it coexists with congenitally corrected transposition of the great arteries (ccTGA), because venous access, atrioventricular valve crossing, and fluoroscopic lead orientation may differ from usual anatomy.Case presentation

A 61-year-old man was admitted with recurrent dizziness and palpitations for 5 years; his symptoms had worsened during the preceding 2 weeks. Preoperative 12-lead electrocardiography showed atrial fibrillation with a slow ventricular response. Twenty-four-hour Holter monitoring documented 707 pauses longer than 2.0 s, with a longest R-R interval of 6.13 s. Echocardiography confirmed mirror-image dextrocardia, situs inversus, and ccTGA. A single-chamber permanent pacemaker was implanted through the right axillary vein. Posteroanterior fluoroscopy defined the right-sided cardiac silhouette; right axillary venography guided venous puncture; right atrial angiography identified the morphologic mitral annular plane; and multi-projection fluoroscopy was used to confirm the final ventricular lead position in the high mid-septal region of the morphologic left ventricle. The procedure lasted 56 min and had no acute complications. At 6-month outpatient follow-up, standard 12-lead electrocardiography, 24-hour Holter monitoring, formal device interrogation, and transthoracic echocardiography showed stable pacing, preserved ventricular performance, and no device-related complication; the paced QRS duration was 144 ms and the pacing burden was 99.8%. During telephone follow-up in June 2026, approximately 1 year after implantation, the patient reported no discomfort.Conclusion

This case describes a structured approach to conventional transvenous pacemaker implantation in mirror-image dextrocardia with ccTGA. In this patient, venography, chamber angiography, and targeted fluoroscopic views reduced procedural uncertainty, and follow-up through 1 year showed clinical stability without recognized complications.

Related

  1. Left-sided surgical approach for tricuspid valve replacement in congenitally corrected transposition of the great arteries with dextrocardia and situs inversus totalis: A case report.
    Chuanjie Yue, Tong Tan, Peng Sun +4
    Journal of cardiothoracic surgeryPeer-reviewedCC BY-NC-NDFull textEpidemiology & public healthEurope PMCDOAJ
  2. Impaired Atrioventricular Conduction System in a Postoperative Heart With Congenitally Corrected Transposition of the Great Arteries
    Taka-aki Matsuyama, Yohsuke Makino, Eri Nakamura +2
    JACC Case ReportsPeer-reviewedCC BY-NC-ND 4.0Full textEpidemiology & public healthPMCDOAJ
  3. Feasibility and Safety of Transthoracic Echocardiography–Guided Transvenous Permanent Pacemaker Implantation Without Fluoroscopy
    JACC. AdvancesPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  4. Optical Coherence Tomography‐Guided Versus Angiography‐Guided Coronary Stent Implantation: An Updated Meta‐Analysis
    Doosup Shin, Yasemin Ciftcikal, Kanitha Phalakornkule +12
    Journal of the American Heart AssociationPeer-reviewedCC BY-NC-NDSurgery & anaesthesiaCrossref
  5. Clarifying Anatomical Terminology in Reports Describing Dextrocardia and Situs Inversus
    Junya Shimamoto, Rintaro Tamaruya
    Internal MedicinePeer-reviewedCC BY-NC-NDFull textEpidemiology & public healthJ-STAGE
BibTeX
@article{cao2026case,
  title = {{Case Report: Angiography-guided transvenous single-chamber pacemaker implantation in mirror-image dextrocardia with congenitally corrected transposition of the great arteries.}},
  author = {Junda Cao and Qin Ao and Jin Ma and Ji Sun},
  journal = {Frontiers in cardiovascular medicine},
  year = {2026},
  month = oct,
  doi = {10.3389/fcvm.2026.1956397},
  url = {https://europepmc.org/article/MED/42898452},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Case Report: Angiography-guided transvenous single-chamber pacemaker implantation in mirror-image dextrocardia with congenitally corrected transposition of the great arteries.
AU  - Junda Cao
AU  - Qin Ao
AU  - Jin Ma
AU  - Ji Sun
PY  - 2026
DA  - 2026/10/05
JO  - Frontiers in cardiovascular medicine
DO  - 10.3389/fcvm.2026.1956397
UR  - https://europepmc.org/article/MED/42898452
AB  - Background  Mirror-image dextrocardia with situs inversus is uncommon. Transvenous permanent pacemaker implantation is technically demanding when it coexists with congenitally corrected transposition of the great arteries (ccTGA), because venous access, atrioventricular valve crossing, and fluoroscopic lead orientation may differ from usual anatomy.Case presentation  A 61-year-old man was admitted with recurrent dizziness and palpitations for 5 years; his symptoms had worsened during the preceding 2 weeks. Preoperative 12-lead electrocardiography showed atrial fibrillation with a slow ventricular response. Twenty-four-hour Holter monitoring documented 707 pauses longer than 2.0 s, with a longest R-R interval of 6.13 s. Echocardiography confirmed mirror-image dextrocardia, situs inversus, and ccTGA. A single-chamber permanent pacemaker was implanted through the right axillary vein. Posteroanterior fluoroscopy defined the right-sided cardiac silhouette; right axillary venography guided venous puncture; right atrial angiography identified the morphologic mitral annular plane; and multi-projection fluoroscopy was used to confirm the final ventricular lead position in the high mid-septal region of the morphologic left ventricle. The procedure lasted 56 min and had no acute complications. At 6-month outpatient follow-up, standard 12-lead electrocardiography, 24-hour Holter monitoring, formal device interrogation, and transthoracic echocardiography showed stable pacing, preserved ventricular performance, and no device-related complication; the paced QRS duration was 144 ms and the pacing burden was 99.8%. During telephone follow-up in June 2026, approximately 1 year after implantation, the patient reported no discomfort.Conclusion  This case describes a structured approach to conventional transvenous pacemaker implantation in mirror-image dextrocardia with ccTGA. In this patient, venography, chamber angiography, and targeted fluoroscopic views reduced procedural uncertainty, and follow-up through 1 year showed clinical stability without recognized complications.
SN  - 2297-055X
ER  -