Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 24 min ago
Peer-reviewedCC BY-NC-ND 4.0BMC Medical Imaging

Deep learning reconstruction combined with contrast enhancement boost improves image quality of low-contrast-dose ctpa: a prospective randomized study

  1. 1Department of Radiology, The First Affiliated Hospital, Sun Yat-sen University, No. 58, Zhongshan Road 2, Guangzhou, 510080 Guangdong China
  2. 2Research Collaboration, Canon Medical Systems, No.10 Huaxia Road, Guangzhou, 510623 Guangdong China

Abstract

Background: High-quality CT pulmonary angiography (CTPA) is vital for pulmonary embolism diagnosis. This study evaluated the effect of combining deep learning reconstruction (DLR) with contrast enhancement boost (CE-boost) in low-contrast-dose CTPA.

Methods: In this prospective randomized trial (September–December 2023), 106 patients were assigned to a low-contrast-dose (3 mL/s, 30 mL; Group A) or standard-contrast-dose (4 mL/s, 50 mL; Group B) CTPA protocol. Four image datasets were generated from each case in Group A using a 2 × 2 factorial design: A1, hybrid iterative reconstruction (HIR); A2, DLR (AiCE); A3, HIR plus CE-boost; A4, DLR plus CE-boost. Group B used HIR. Quantitative (CT attenuation, noise, SNR, CNR) and qualitative (overall image quality, subsegmental artery visibility) endpoints were assessed with linear mixed models and ART ANOVA with Holm correction.

Results: Each group comprised 53 patients (mean age: 59 ± 15 vs. 58 ± 18 years; 27 vs. 26 women). DLR significantly reduced noise and improved SNR/CNR (all Holm-corrected p < 0.001). CE-boost significantly increased CT attenuation, SNR, and CNR (all p < 0.001) without affecting noise. A significant DLR × CE-boost interaction was observed for CNR in all ROIs (all p < 0.05), indicating synergy. Qualitatively, DLR improved both overall quality and visibility, whereas CE-boost improved visibility only. The combined protocol (A4) achieved the highest CNR and visibility among all four datasets, significantly surpassing both the baseline low-contrast-dose (A1) and standard-contrast-dose (Group B) protocols (all Bonferroni-corrected p < 0.0083/0.025).

Conclusions: Combining DLR with CE-boost synergistically optimizes low-contrast-dose CTPA, enabling a 40% reduction in iodine load and a 25% reduction in injection rate while enhancing image quality beyond that of standard-contrast-dose imaging. This protocol may offer a viable strategy for patients requiring strict contrast limitation.

Related

  1. A Commentary on “Erector Spinae Plane Block Combined With Local Infiltration Analgesia for Posterior Lumbar Interbody Fusion: Prospective, Double-Blind, Randomized Controlled Trial”
    Michal Ziga
    NeurospinePeer-reviewedCC BY-NC 4.0Full textSurgery & anaesthesiaPMC
  2. A Commentary on “Erector Spinae Plane Block Combined With Local Infiltration Analgesia for Posterior Lumbar Interbody Fusion: Prospective, Double-Blind, Randomized Controlled Trial”
    Hiroyuki Katoh
    NeurospinePeer-reviewedCC BY-NC 4.0Full textSurgery & anaesthesiaPMC
  3. The no mesh breast reconstruction evaluation (No-BRA) study: protocol for a national prospective audit and shared learning study of pre-pectoral implant-based breast reconstruction with no mesh
    Jing Qin Tay, Thessa R. Friebel, Daniel Kyle +7
    International journal of surgery protocolsPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  4. Oliceridine vs Sufentanil Combined With Ondansetron for Postoperative Nausea and Vomiting and QTc Interval in Hysteroscopic Surgery: A Prospective Randomized Controlled Study
    Zhijia Guo, Yanan Wu, Yuqian Sang
    Medical Science Monitor: International Medical Journal of Experimental and Clinical ResearchPeer-reviewedCC BY-NC-ND 4.0Full textSurgery & anaesthesiaPMC
  5. Comparative Efficacy of Pecto-Intercostal Facial Plane Block vs Transversus Thoracic Facial Plane Block Combined with Rectus Sheath Block for Post-Sternotomy Analgesia: A Prospective Randomized Controlled Trial
    Priya Gupta, Ravikanth Pula, Venu Polapally +4
    Annals of Cardiac AnaesthesiaPeer-reviewedCC BY-NC-SA 4.0Full text1 citedSurgery & anaesthesiaPMC
BibTeX
@article{xie2026deep,
  title = {{Deep learning reconstruction combined with contrast enhancement boost improves image quality of low-contrast-dose ctpa: a prospective randomized study}},
  author = {Dingxiang Xie and Jingyi Lin and Mulan Huang and Zhiman Lai and Xufeng Yang and Rulin Xu and Huasong Cai and Hui Ma},
  journal = {BMC Medical Imaging},
  year = {2026},
  month = oct,
  doi = {10.1186/s12880-026-02998-6},
  url = {https://doi.org/10.1186/s12880-026-02998-6},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Deep learning reconstruction combined with contrast enhancement boost improves image quality of low-contrast-dose ctpa: a prospective randomized study
AU  - Dingxiang Xie
AU  - Jingyi Lin
AU  - Mulan Huang
AU  - Zhiman Lai
AU  - Xufeng Yang
AU  - Rulin Xu
AU  - Huasong Cai
AU  - Hui Ma
PY  - 2026
DA  - 2026/10/30
JO  - BMC Medical Imaging
DO  - 10.1186/s12880-026-02998-6
UR  - https://doi.org/10.1186/s12880-026-02998-6
AB  - Background: High-quality CT pulmonary angiography (CTPA) is vital for pulmonary embolism diagnosis. This study evaluated the effect of combining deep learning reconstruction (DLR) with contrast enhancement boost (CE-boost) in low-contrast-dose CTPA.  Methods: In this prospective randomized trial (September–December 2023), 106 patients were assigned to a low-contrast-dose (3 mL/s, 30 mL; Group A) or standard-contrast-dose (4 mL/s, 50 mL; Group B) CTPA protocol. Four image datasets were generated from each case in Group A using a 2 × 2 factorial design: A1, hybrid iterative reconstruction (HIR); A2, DLR (AiCE); A3, HIR plus CE-boost; A4, DLR plus CE-boost. Group B used HIR. Quantitative (CT attenuation, noise, SNR, CNR) and qualitative (overall image quality, subsegmental artery visibility) endpoints were assessed with linear mixed models and ART ANOVA with Holm correction.  Results: Each group comprised 53 patients (mean age: 59 ± 15 vs. 58 ± 18 years; 27 vs. 26 women). DLR significantly reduced noise and improved SNR/CNR (all Holm-corrected p < 0.001). CE-boost significantly increased CT attenuation, SNR, and CNR (all p < 0.001) without affecting noise. A significant DLR × CE-boost interaction was observed for CNR in all ROIs (all p < 0.05), indicating synergy. Qualitatively, DLR improved both overall quality and visibility, whereas CE-boost improved visibility only. The combined protocol (A4) achieved the highest CNR and visibility among all four datasets, significantly surpassing both the baseline low-contrast-dose (A1) and standard-contrast-dose (Group B) protocols (all Bonferroni-corrected p < 0.0083/0.025).  Conclusions: Combining DLR with CE-boost synergistically optimizes low-contrast-dose CTPA, enabling a 40% reduction in iodine load and a 25% reduction in injection rate while enhancing image quality beyond that of standard-contrast-dose imaging. This protocol may offer a viable strategy for patients requiring strict contrast limitation.
SN  - 1471-2342
ER  -