Ultra-high-pitch photon-counting computed tomography (PCCT) versus ultra-high-pitch dual-source computed tomography (DSCT) for coronary artery disease evaluation in transcatheter aortic valve implantation (TAVI) patients.
- 1Department of Diagnostic and Interventional Radiology, University Hospital RWTH Aachen, Pauwelsstraße 30, Aachen, 52074, Germany.
- 2Department of Cardiology, Angiology and Internal Intensive Care, University Hospital RWTH Aachen, Pauwelsstraße 30, Aachen, 52074, Germany.
Abstract
To compare radiation dose and image quality of coronary artery reconstructions obtained from non-coronary-dedicated transcatheter aortic valve implantation (TAVI) planning CT scans using ultra-high-pitch photon-counting CT (PCCT) and ultra-high-pitch energy-integrating detector dual-source CT (EID-DSCT; hereafter referred to as DSCT), including assessment of the feasibility of coronary artery evaluation according to the Coronary Artery Disease Reporting and Data System (CAD-RADS). Retrospective study on consecutive patients with aortic valve stenosis (AS) undergoing contrast-enhanced TAVI planning CT, either PCCT or DSCT between August 2021 and June 2023. CT dose index (CTDI) and dose length product (DLP) were used to calculate the effective radiation dose (eRD). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated using standardized region-of-interest (ROI) analysis. Coronary arteries were evaluated by three independent radiologists using 5-point Likert scales followed by a classification according to the CAD-RADS system. 187 patients (83 female, median age 82, IQR: 76-84) underwent 190 CT-examinations, 103 PCCT (54.2%) and 87 (45.8%) DSCT. Three patients underwent both PCCT and DSCT for clinical reasons. Mean CTDI and DLP were significantly lower in PCCT compared to DSCT (21.9 vs. 52.8 and 607.9 vs. 906.8, respectively; both p < 0.001), with a correspondingly lower mean effective radiation dose (eRD) in PCCT compared to DSCT (10.3 ± 5.4 mSv vs. 15.4 ± 5.6 mSv, p < 0.001). While both SNR and CNR were lower in PCCT than in DSCT (SNR: 35.28 ± 11.63 in PCCT vs. 45.6 ± 16.3 in DSCT, p < 0.001; CNR: 49.25 ± 13.31 in PCCT vs. 57.42 v ± 22.55 in DSCT, p = 0.004), PCCT outperformed DSCT in every one of the eleven visual image categories. Overall image quality was rated as good or excellent in 71.8% (74/103) of PCCT vs. 19.5% (17/87) of DSCT scans. Coronary reconstructions were rated as good or excellent in 72.8% (75/103) of PCCT vs. 20.7% of DSCT datasets. CAD-RADS [1-5] rating was possible in 68.9% (71/103) of PCCT vs. 39.1% (34/87) of DSCT datasets. Photon-counting computed tomography (PCCT) allows for significantly improved assessability of the coronary arteries in TAVI planning CT compared with dual-source CT (DSCT), while achieving a substantially lower radiation dose.
Related
- Single-Stage Computed Tomography Angiography, Percutaneous Coronary Intervention, and Transcatheter Aortic Valve Replacement in an Octogenarian With Femoral Neck Fracture, Non-ST-Elevation Myocardial Infarction, and Severe Aortic Stenosis: A Case Report and Literature Review of Multidisciplinary Approaches
- Mitochondrial DNA depletion syndrome 12B: role of photon-counting computed tomography in detection of cardiac involvement—a case report
- Cuboid stress fracture as an uncommon cause of lateral foot pain: Correlation between magnetic resonance imaging and photon-counting computed tomography - A case report
- Photon-Counting Computed Tomography Enables Image-Guided Navigation of the Paranasal Sinuses at Ultra-Low Radiation Dose: An Initial Cadaveric Study
- Cuboid stress fracture as an uncommon cause of lateral foot pain: Correlation between magnetic resonance imaging and photon-counting computed tomography - A case report
BibTeX
@article{mecking2026ultrahighpitch,
title = {{Ultra-high-pitch photon-counting computed tomography (PCCT) versus ultra-high-pitch dual-source computed tomography (DSCT) for coronary artery disease evaluation in transcatheter aortic valve implantation (TAVI) patients.}},
author = {Ines Mecking and Marc von der Stück and Eric Corban and Michael Frick and Jörg Schröder and Roman Iwa and Christiane K Kuhl and Timm Dirrichs},
journal = {European journal of radiology open},
year = {2026},
month = oct,
doi = {10.1016/j.ejro.2026.100824},
url = {https://europepmc.org/article/MED/42997559},
note = {CC BY},
}
RIS
TY - JOUR
TI - Ultra-high-pitch photon-counting computed tomography (PCCT) versus ultra-high-pitch dual-source computed tomography (DSCT) for coronary artery disease evaluation in transcatheter aortic valve implantation (TAVI) patients.
AU - Ines Mecking
AU - Marc von der Stück
AU - Eric Corban
AU - Michael Frick
AU - Jörg Schröder
AU - Roman Iwa
AU - Christiane K Kuhl
AU - Timm Dirrichs
PY - 2026
DA - 2026/10/28
JO - European journal of radiology open
DO - 10.1016/j.ejro.2026.100824
UR - https://europepmc.org/article/MED/42997559
AB - To compare radiation dose and image quality of coronary artery reconstructions obtained from non-coronary-dedicated transcatheter aortic valve implantation (TAVI) planning CT scans using ultra-high-pitch photon-counting CT (PCCT) and ultra-high-pitch energy-integrating detector dual-source CT (EID-DSCT; hereafter referred to as DSCT), including assessment of the feasibility of coronary artery evaluation according to the Coronary Artery Disease Reporting and Data System (CAD-RADS). Retrospective study on consecutive patients with aortic valve stenosis (AS) undergoing contrast-enhanced TAVI planning CT, either PCCT or DSCT between August 2021 and June 2023. CT dose index (CTDI) and dose length product (DLP) were used to calculate the effective radiation dose (eRD). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated using standardized region-of-interest (ROI) analysis. Coronary arteries were evaluated by three independent radiologists using 5-point Likert scales followed by a classification according to the CAD-RADS system. 187 patients (83 female, median age 82, IQR: 76-84) underwent 190 CT-examinations, 103 PCCT (54.2%) and 87 (45.8%) DSCT. Three patients underwent both PCCT and DSCT for clinical reasons. Mean CTDI and DLP were significantly lower in PCCT compared to DSCT (21.9 vs. 52.8 and 607.9 vs. 906.8, respectively; both p < 0.001), with a correspondingly lower mean effective radiation dose (eRD) in PCCT compared to DSCT (10.3 ± 5.4 mSv vs. 15.4 ± 5.6 mSv, p < 0.001). While both SNR and CNR were lower in PCCT than in DSCT (SNR: 35.28 ± 11.63 in PCCT vs. 45.6 ± 16.3 in DSCT, p < 0.001; CNR: 49.25 ± 13.31 in PCCT vs. 57.42 v ± 22.55 in DSCT, p = 0.004), PCCT outperformed DSCT in every one of the eleven visual image categories. Overall image quality was rated as good or excellent in 71.8% (74/103) of PCCT vs. 19.5% (17/87) of DSCT scans. Coronary reconstructions were rated as good or excellent in 72.8% (75/103) of PCCT vs. 20.7% of DSCT datasets. CAD-RADS [1-5] rating was possible in 68.9% (71/103) of PCCT vs. 39.1% (34/87) of DSCT datasets. Photon-counting computed tomography (PCCT) allows for significantly improved assessability of the coronary arteries in TAVI planning CT compared with dual-source CT (DSCT), while achieving a substantially lower radiation dose.
SN - 2352-0477
ER -