Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 23 min ago
Peer-reviewedCC BYMarine drugs

Characterization of Two Functional Assays and Development of Quality Standards Using Tetrodotoxin and µ-Conotoxin KIIIA as Test Compounds Against NaV Channels.

  1. 1Emergency Response Branch, Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341, USA.
  2. 2Battelle Memorial Institute, 505 King Avenue, Columbus, OH 43201, USA.
  3. 3Oak Ridge Institute for Science, Centers for Disease Control and Prevention, Atlanta, GA 30341, USA.

Abstract

This study evaluates two commonly used in vitro techniques to assess compound potencies: patch-clamp electrophysiology and fluorescence membrane potential assay. Furthermore, a quality framework to assess Tetrodotoxin and µ-conotoxin KIIIA activity on the voltage-gated sodium (NaV) receptors NaV 1.4 and NaV 1.7 using patch-clamp electrophysiology in a controlled, comparative manner is developed and described. The framework includes verification of cell line receptor overexpression, assay characterization using a well-studied reference compound, data curation, and test compound potency assessment. Data generated here support previous claims that patch-clamp electrophysiology is the gold standard for potency assessments, being a more reproducible and sensitive technique than the fluorescence membrane potential assay. Patch-clamp electrophysiology characterization using nine replicate dose-response curves over three days generated similar half-maximal inhibitory concentration (IC₅₀) values to much larger datasets and the existing literature for the sodium channel cell lines selected for these studies. This framework can be adapted by other laboratories for rapid development and characterization of high-throughput, robust, and efficient functional assays to assess quality and consistency of measurements over time.

Related

  1. Synthesis and electrophysiological characterization of TxO6, an O1 gene superfamily conotoxin that inhibits potassium currents.
    Maojun Zhou, Yun Wu, Manyi Yang
    The journal of venomous animals and toxins including tropical diseasesPeer-reviewedCC BYFull textMolecular biology & gene regulationEurope PMC
  2. Cryo-EM Structure of a Triazole alpha-Conotoxin GI Mimetic Bound to the Muscle-Type Nicotinic Acetylcholine Receptor
    O. Shepperson, M. Capper, C. Holdship +15
    bioRxivPreprintCC BYFull textMolecular biology & gene regulationbioRxiv
  3. Benchmarking Structural Models of α-Conotoxin-Nicotinic Acetylcholine Receptor Complexes: Apo-Conformer Selection, Interface Information, and Deep-Learning Co-Folding.
    SungYeop Jung, Lee-Seung Kwon
    ToxinsPeer-reviewedCC BYFull textMolecular biology & gene regulationEurope PMC
  4. Defense mechanisms of Takifugu fasciatus in fatty liver adaptation and tetrodotoxin resistance
    Xuechun Zang, Tao Wang, Ruhua Shang +7
    Communications BiologyPeer-reviewedCC BY-NC-ND 4.0Full textEnzymology & metabolismPMC
  5. Strategies for Overcoming the Purification Challenges of Meis1 and HoxA9 and Their Functional Characterization
    I. A. Olaosebikan, K. C. Courtney, H. Karatas Bristow
    bioRxivPreprintAll rights reservedFull textGeneral biochemistrybioRxiv
BibTeX
@article{housman2026characterization,
  title = {{Characterization of Two Functional Assays and Development of Quality Standards Using Tetrodotoxin and µ-Conotoxin KIIIA as Test Compounds Against NaV Channels.}},
  author = {Max Housman and Judee Grace E Nemeño and Jessica L Armstong and Elizabeth Hamelin and Rebekah Wharton},
  journal = {Marine drugs},
  year = {2026},
  month = nov,
  doi = {10.3390/md24110415},
  url = {https://europepmc.org/article/MED/43083170},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Characterization of Two Functional Assays and Development of Quality Standards Using Tetrodotoxin and µ-Conotoxin KIIIA as Test Compounds Against NaV Channels.
AU  - Max Housman
AU  - Judee Grace E Nemeño
AU  - Jessica L Armstong
AU  - Elizabeth Hamelin
AU  - Rebekah Wharton
PY  - 2026
DA  - 2026/11/19
JO  - Marine drugs
DO  - 10.3390/md24110415
UR  - https://europepmc.org/article/MED/43083170
AB  - This study evaluates two commonly used in vitro techniques to assess compound potencies: patch-clamp electrophysiology and fluorescence membrane potential assay. Furthermore, a quality framework to assess Tetrodotoxin and µ-conotoxin KIIIA activity on the voltage-gated sodium (NaV) receptors NaV 1.4 and NaV 1.7 using patch-clamp electrophysiology in a controlled, comparative manner is developed and described. The framework includes verification of cell line receptor overexpression, assay characterization using a well-studied reference compound, data curation, and test compound potency assessment. Data generated here support previous claims that patch-clamp electrophysiology is the gold standard for potency assessments, being a more reproducible and sensitive technique than the fluorescence membrane potential assay. Patch-clamp electrophysiology characterization using nine replicate dose-response curves over three days generated similar half-maximal inhibitory concentration (IC₅₀) values to much larger datasets and the existing literature for the sodium channel cell lines selected for these studies. This framework can be adapted by other laboratories for rapid development and characterization of high-throughput, robust, and efficient functional assays to assess quality and consistency of measurements over time.
SN  - 1660-3397
ER  -