Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 39 min ago
Peer-reviewedCC BYIEEE Transactions on Nuclear Science

Collimator Design for a Brain SPECT/MRI Insert

Abstract

This project's goal is to design a SPECT insert for a clinical MRI system for simultaneous brain SPECT/MR imaging, with a high-sensitivity collimator and high-resolution detectors. We have compared eight collimator designs, four multi-pinhole and four multi-slit slit-slat configurations. The collimation was designed for a system with 2 rings of 25 5 × 5 cm detectors. We introduce the concept of 1/2-pinhole and 1/2-slit, which are transaxially shared between two adjacent detectors. Analytical geometric efficiency was calculated for an activity distribution corresponding to a human brain and a range of intrinsic detector resolutions Ri and target resolutions Rt at the centre of the FOV. Noise-free data were simulated with and without depth-of-interaction (DOI) information, 0.8 mm Ri and 10 mm Rt FWHM, and reconstructed for uniform, Defrise, Derenzo, and Zubal brain phantoms. Comparing the multi-pinhole and multi-slit slit-slat collimators, the former gives better reconstructed uniformity and transaxial resolution, while the latter gives better axial resolution. Although the 2 ×2-pinhole and 2-slit designs give the highest sensitivities, they result in a sub-optimal utilisation of the detector FOV. The best options are therefore the 5+ 2 1/2-pinhole and the 1 + 2 1/2-slit systems, with sensitivities of 1.8 ×10-4and 3.2 ×10-4, respectively. Noiseless brain phantom reconstructions with the multi-pinhole collimator are slightly superior as compared to slit-slat, in terms of symmetry and accuracy of the activity distribution, but the same is not true when noise is included. DOI information reduces artefacts and improves uniformity in geometric phantoms. Further evaluation is needed with prototype collimators.

Related

  1. Design of the Electron-Beam Collimator for the Electron-Ion Collider
    Andrii Natochii, Elke-Caroline Aschenauer, Jay Best +5
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationarXiv
  2. Work to insert a particle into an active fluid
    Freddy Cisneros, Alexandre Solon, Jordan Horowitz
    EPL - Europhysics LettersPeer-reviewedCC BYStatistical & nonlinear physicsHAL
  3. A software tool for parametric collimator creation for linac-based preclinical irradiation studies
    Joseph B. Schulz, Dixin Chen, Lloyd Emmanuel Kamole Ghomsi +5
    arXivPreprintCC BY 4.0Full textBiological & medical physicsarXiv
  4. Daily Multi‐Leaf Collimator positional error prediction using machine learning: A Dynalog‐based approach for patient specific quality assurance
    Samira Aghaei Akizi, Seyed Mahmoud Reza Aghamiri, Zahra Siavashpour +2
    Journal of Applied Clinical Medical PhysicsPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationPMC
  5. Geometry and cooling effects on an induction self-heating insert for rapid mold temperature control: Experimental, Multiphysics, and artificial neural network-based analysis
    Thanh Trung Do, Tran Minh The Uyen, Pham Son Minh
    PLOS OnePeer-reviewedCC BY 4.0Full textBioinformatics & computational biologyNeurosciencePLOSPMC
BibTeX
@article{salvado2026collimator,
  title = {{Collimator Design for a Brain SPECT/MRI Insert}},
  author = {Debora Salvado and Kjell Erlandsson and Alexandre Bousse and Michele Occhipinti and Paolo Busca and Carlo Fiorini and Brian Hutton},
  journal = {IEEE Transactions on Nuclear Science},
  year = {2026},
  month = sep,
  doi = {10.1109/tns.2015.2450017},
  url = {https://hal.science/hal-05763802v1},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Collimator Design for a Brain SPECT/MRI Insert
AU  - Debora Salvado
AU  - Kjell Erlandsson
AU  - Alexandre Bousse
AU  - Michele Occhipinti
AU  - Paolo Busca
AU  - Carlo Fiorini
AU  - Brian Hutton
PY  - 2026
DA  - 2026/09/25
JO  - IEEE Transactions on Nuclear Science
DO  - 10.1109/tns.2015.2450017
UR  - https://hal.science/hal-05763802v1
AB  - This project's goal is to design a SPECT insert for a clinical MRI system for simultaneous brain SPECT/MR imaging, with a high-sensitivity collimator and high-resolution detectors. We have compared eight collimator designs, four multi-pinhole and four multi-slit slit-slat configurations. The collimation was designed for a system with 2 rings of 25 5 × 5 cm detectors. We introduce the concept of 1/2-pinhole and 1/2-slit, which are transaxially shared between two adjacent detectors. Analytical geometric efficiency was calculated for an activity distribution corresponding to a human brain and a range of intrinsic detector resolutions Ri and target resolutions Rt at the centre of the FOV. Noise-free data were simulated with and without depth-of-interaction (DOI) information, 0.8 mm Ri and 10 mm Rt FWHM, and reconstructed for uniform, Defrise, Derenzo, and Zubal brain phantoms. Comparing the multi-pinhole and multi-slit slit-slat collimators, the former gives better reconstructed uniformity and transaxial resolution, while the latter gives better axial resolution. Although the 2 ×2-pinhole and 2-slit designs give the highest sensitivities, they result in a sub-optimal utilisation of the detector FOV. The best options are therefore the 5+ 2 1/2-pinhole and the 1 + 2 1/2-slit systems, with sensitivities of 1.8 ×10-4and 3.2 ×10-4, respectively. Noiseless brain phantom reconstructions with the multi-pinhole collimator are slightly superior as compared to slit-slat, in terms of symmetry and accuracy of the activity distribution, but the same is not true when noise is included. DOI information reduces artefacts and improves uniformity in geometric phantoms. Further evaluation is needed with prototype collimators.
SN  - 0018-9499
SN  - 1558-1578
ER  -