Deep learning–based automatic measurement of spinal alignment and implant detection in scoliosis radiographs
7 affiliations
- 1Department of Orthopedic Surgery, Sakai City Medical Center, Osaka, Japan
- 2Department of Artificial Intelligence in Diagnostic Radiology, Graduate School of Medicine, The University of Osaka, Osaka, Japan
- 3Department of Orthopedic Surgery, Graduate School of Medicine, The University of Osaka, Osaka, Japan
- 4Strategic Global Partnership and X-Innovation Initiative, Graduate School of Medicine, The University of Osaka, Osaka, Japan
- 5Department of Orthopedic Surgery, JCHO Osaka Hospital, Osaka, Japan
- 6Department of Orthopedic Surgery, Osaka Rosai Hospital, Osaka, Japan
- 7Department of Orthopedic Surgery, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Japan
Abstract
Deep learning–based automated analysis offers the potential to streamline workflows, improve reproducibility, and reduce clinician workload. We developed an artificial intelligence (AI) system based on convolutional neural networks to automatically measure spinal alignment and detect spinal implants (pedicle screws and hooks combined as a single category) from scoliosis radiographs. A total of 4585 radiographs from 1671 adolescent idiopathic scoliosis patients across 10 institutions in 2 countries were used to train, validate, and externally test the model. The AI measured coronal and sagittal parameters with mean absolute errors (MAEs) of 2.7° (r = 0.99) for the major curve and 3.7° (r = 0.91) for thoracic kyphosis, regardless of implant presence. Vertebral numbering was performed with an accuracy of 0.97 for recognizing transitional vertebrae. Implant detection achieved high accuracy, with an MAE of 0.18 implants per image (r = 0.99). This comprehensive, multi-institutional validation demonstrates the clinical and research utility of the model in enabling fully automated assessment of spinal deformity. While external validation for coronal preoperative measurements was conducted across four cohorts in four countries, sagittal and postoperative measurements were externally validated at two sites (the United States and Japan); broader multi-region validation of sagittal and postoperative measurements, therefore, remains an important direction for future work.
Related
- Assessment of Curve Flexibility in Idiopathic Scoliosis Patients With Severe Scoliosis (Cobb Angle ≥ 90o): Comparison Between the Supine Traction Radiograph Versus the Physician Supervised Supine Side Bending Radiographs
- Flexibility Assessment of Adolescent Idiopathic Scoliosis Using Fulcrum Bending Radiographs in the Modern Era
- Single-leg versus double-leg weight-bearing radiographs for coronal alignment assessment in patients with lower extremity trauma
- A multi-task deep learning framework for simultaneous classification of scoliosis severity and sagittal parameters from full-spine radiographs
- AI-Based Automated Segmentation of the Mandibular Cortex and Mental Foramen for Radiomorphometric Measurement on Panoramic Radiographs: A Feasibility Study
BibTeX
@article{nakajima2026deep,
title = {{Deep learning–based automatic measurement of spinal alignment and implant detection in scoliosis radiographs}},
author = {Nozomu Nakajima and Yuki Suzuki and Koki Hosozawa and Koki Kishimoto and Kosuke Kita and Yuya Kanie and Masayuki Furuya and Kei Shinyashiki and Yuichiro Ukon and Shota Takenaka and Takashi Kaito and Noriaki Yokogawa and Masatoshi Hori and Seiji Okada and Takahito Fujimori},
journal = {NPJ Digital Medicine},
year = {2026},
month = jul,
doi = {10.1038/s41746-026-03020-7},
url = {https://doi.org/10.1038/s41746-026-03020-7},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Deep learning–based automatic measurement of spinal alignment and implant detection in scoliosis radiographs
AU - Nozomu Nakajima
AU - Yuki Suzuki
AU - Koki Hosozawa
AU - Koki Kishimoto
AU - Kosuke Kita
AU - Yuya Kanie
AU - Masayuki Furuya
AU - Kei Shinyashiki
AU - Yuichiro Ukon
AU - Shota Takenaka
AU - Takashi Kaito
AU - Noriaki Yokogawa
AU - Masatoshi Hori
AU - Seiji Okada
AU - Takahito Fujimori
PY - 2026
DA - 2026/07/17
JO - NPJ Digital Medicine
DO - 10.1038/s41746-026-03020-7
UR - https://doi.org/10.1038/s41746-026-03020-7
AB - Deep learning–based automated analysis offers the potential to streamline workflows, improve reproducibility, and reduce clinician workload. We developed an artificial intelligence (AI) system based on convolutional neural networks to automatically measure spinal alignment and detect spinal implants (pedicle screws and hooks combined as a single category) from scoliosis radiographs. A total of 4585 radiographs from 1671 adolescent idiopathic scoliosis patients across 10 institutions in 2 countries were used to train, validate, and externally test the model. The AI measured coronal and sagittal parameters with mean absolute errors (MAEs) of 2.7° (r = 0.99) for the major curve and 3.7° (r = 0.91) for thoracic kyphosis, regardless of implant presence. Vertebral numbering was performed with an accuracy of 0.97 for recognizing transitional vertebrae. Implant detection achieved high accuracy, with an MAE of 0.18 implants per image (r = 0.99). This comprehensive, multi-institutional validation demonstrates the clinical and research utility of the model in enabling fully automated assessment of spinal deformity. While external validation for coronal preoperative measurements was conducted across four cohorts in four countries, sagittal and postoperative measurements were externally validated at two sites (the United States and Japan); broader multi-region validation of sagittal and postoperative measurements, therefore, remains an important direction for future work.
SN - 2398-6352
ER -