Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 32 min ago
Peer-reviewedCC BY 4.0NPJ Digital Medicine

Deep learning–based automatic measurement of spinal alignment and implant detection in scoliosis radiographs

3 more authors
7 affiliations
  1. 1Department of Orthopedic Surgery, Sakai City Medical Center, Osaka, Japan
  2. 2Department of Artificial Intelligence in Diagnostic Radiology, Graduate School of Medicine, The University of Osaka, Osaka, Japan
  3. 3Department of Orthopedic Surgery, Graduate School of Medicine, The University of Osaka, Osaka, Japan
  4. 4Strategic Global Partnership and X-Innovation Initiative, Graduate School of Medicine, The University of Osaka, Osaka, Japan
  5. 5Department of Orthopedic Surgery, JCHO Osaka Hospital, Osaka, Japan
  6. 6Department of Orthopedic Surgery, Osaka Rosai Hospital, Osaka, Japan
  7. 7Department of Orthopedic Surgery, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Japan

Abstract

Deep learning–based automated analysis offers the potential to streamline workflows, improve reproducibility, and reduce clinician workload. We developed an artificial intelligence (AI) system based on convolutional neural networks to automatically measure spinal alignment and detect spinal implants (pedicle screws and hooks combined as a single category) from scoliosis radiographs. A total of 4585 radiographs from 1671 adolescent idiopathic scoliosis patients across 10 institutions in 2 countries were used to train, validate, and externally test the model. The AI measured coronal and sagittal parameters with mean absolute errors (MAEs) of 2.7° (r = 0.99) for the major curve and 3.7° (r = 0.91) for thoracic kyphosis, regardless of implant presence. Vertebral numbering was performed with an accuracy of 0.97 for recognizing transitional vertebrae. Implant detection achieved high accuracy, with an MAE of 0.18 implants per image (r = 0.99). This comprehensive, multi-institutional validation demonstrates the clinical and research utility of the model in enabling fully automated assessment of spinal deformity. While external validation for coronal preoperative measurements was conducted across four cohorts in four countries, sagittal and postoperative measurements were externally validated at two sites (the United States and Japan); broader multi-region validation of sagittal and postoperative measurements, therefore, remains an important direction for future work.

Related

  1. Assessment of Curve Flexibility in Idiopathic Scoliosis Patients With Severe Scoliosis (Cobb Angle ≥ 90o): Comparison Between the Supine Traction Radiograph Versus the Physician Supervised Supine Side Bending Radiographs
    Chris Yin Wei Chan, Josephine Rebecca Chandren, Evonne Yee Wern Tan +3
    Global Spine JournalPeer-reviewedCC BY-NC-ND 4.0Full textSurgery & anaesthesiaPMC
  2. Flexibility Assessment of Adolescent Idiopathic Scoliosis Using Fulcrum Bending Radiographs in the Modern Era
    Samuel Yan Jin Fang, Kenny Yat Hong Kwan
    NeurospinePeer-reviewedCC BY-NC 4.0Full textSurgery & anaesthesiaPMC
  3. Single-leg versus double-leg weight-bearing radiographs for coronal alignment assessment in patients with lower extremity trauma
    Naya Pabla, Kairo Noronha, Sathyagopal Siddapureddy +6
    SICOT-JPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  4. A multi-task deep learning framework for simultaneous classification of scoliosis severity and sagittal parameters from full-spine radiographs
    Yanyun Gou, Jiezhou He, Mingfeng Lin +4
    BMC Medical ImagingPeer-reviewedCC BY-NC-ND 4.0Full textSurgery & anaesthesiaPMC
  5. AI-Based Automated Segmentation of the Mandibular Cortex and Mental Foramen for Radiomorphometric Measurement on Panoramic Radiographs: A Feasibility Study
    Sinem Atay Görür, Merve Önder, Özer Çelik +4
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{nakajima2026deep,
  title = {{Deep learning–based automatic measurement of spinal alignment and implant detection in scoliosis radiographs}},
  author = {Nozomu Nakajima and Yuki Suzuki and Koki Hosozawa and Koki Kishimoto and Kosuke Kita and Yuya Kanie and Masayuki Furuya and Kei Shinyashiki and Yuichiro Ukon and Shota Takenaka and Takashi Kaito and Noriaki Yokogawa and Masatoshi Hori and Seiji Okada and Takahito Fujimori},
  journal = {NPJ Digital Medicine},
  year = {2026},
  month = jul,
  doi = {10.1038/s41746-026-03020-7},
  url = {https://doi.org/10.1038/s41746-026-03020-7},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Deep learning–based automatic measurement of spinal alignment and implant detection in scoliosis radiographs
AU  - Nozomu Nakajima
AU  - Yuki Suzuki
AU  - Koki Hosozawa
AU  - Koki Kishimoto
AU  - Kosuke Kita
AU  - Yuya Kanie
AU  - Masayuki Furuya
AU  - Kei Shinyashiki
AU  - Yuichiro Ukon
AU  - Shota Takenaka
AU  - Takashi Kaito
AU  - Noriaki Yokogawa
AU  - Masatoshi Hori
AU  - Seiji Okada
AU  - Takahito Fujimori
PY  - 2026
DA  - 2026/07/17
JO  - NPJ Digital Medicine
DO  - 10.1038/s41746-026-03020-7
UR  - https://doi.org/10.1038/s41746-026-03020-7
AB  - Deep learning–based automated analysis offers the potential to streamline workflows, improve reproducibility, and reduce clinician workload. We developed an artificial intelligence (AI) system based on convolutional neural networks to automatically measure spinal alignment and detect spinal implants (pedicle screws and hooks combined as a single category) from scoliosis radiographs. A total of 4585 radiographs from 1671 adolescent idiopathic scoliosis patients across 10 institutions in 2 countries were used to train, validate, and externally test the model. The AI measured coronal and sagittal parameters with mean absolute errors (MAEs) of 2.7° (r = 0.99) for the major curve and 3.7° (r = 0.91) for thoracic kyphosis, regardless of implant presence. Vertebral numbering was performed with an accuracy of 0.97 for recognizing transitional vertebrae. Implant detection achieved high accuracy, with an MAE of 0.18 implants per image (r = 0.99). This comprehensive, multi-institutional validation demonstrates the clinical and research utility of the model in enabling fully automated assessment of spinal deformity. While external validation for coronal preoperative measurements was conducted across four cohorts in four countries, sagittal and postoperative measurements were externally validated at two sites (the United States and Japan); broader multi-region validation of sagittal and postoperative measurements, therefore, remains an important direction for future work.
SN  - 2398-6352
ER  -