Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 35 min ago
PreprintarXiv licencearXiv

Experimental Investigation of Heat Transfer in Axisymmetric Open Cavities at Hypersonic Speeds

Abstract

An experimental investigation was conducted to characterize the heat-transfer behavior of an axisymmetric cavity mounted on a cone with a semi-apex angle of (48∘) under Mach 6 freestream conditions in a Ludwieg tunnel. The effects of cavity geometry, represented by the length-to-depth ratio (L/D = 0.5, 1.0, 2.0, 4.0, and 6.0), rear-wall height-to-depth ratio (h/D = −0.25, 0, and 0.5), and Reynolds number (ReD = 23000 − 74000) were systematically investigated. Flow-field characteristics and surface heat-transfer behavior were examined using schlieren and planar laser Rayleigh scattering visualization techniques, together with surface pressure and heat-transfer measurements. The results indicate that increasing the cavity length-to-depth ratio leads to a reduction in the downstream Stanton number (Std). For the longest cavity L/D = 6, however, the downstream Stanton number was found to exceed the upstream value (Stu) indicating enhanced heat transfer in the region downstream of the cavity.

Related

  1. Experimental Investigation of Hypersonic Shock-Wave/Boundary-Layer Interaction Dynamics Using Plasma-Generated Disturbances
    Emma E. Nicotra, Francis A. Centlivre, Jonathan Poggie +2
    arXivPreprintarXiv licenceFull textFluid dynamicsPlasma physicsarXiv
  2. Hypersonic Flow Over an Axisymmetric Open Cavity: Effects of Segmentation Angle and Reynolds Number
    T. V. Krishna, Soumya R. Nanda, S. K. Karthick +1
    arXivPreprintarXiv licenceFull textFluid dynamicsarXiv
  3. Experimental implementation of a finite-time controller for the axisymmetric vibration modes of a tom-tom drum
    Marc Wijnand, Brigitte d'Andréa-Novel, Thomas Hélie +1
    Journal of Theoretical, Computational and Applied MechanicsPeer-reviewedCC BY 4.0Full textGeneral physicsHAL
  4. Full Poincaré Beam Through Fresnel-Scaled FSO Turbulence: An Experimental Statistical Investigation and Performance Analysis
    Vaishali Bhatt, Abhishek Dixit
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  5. Experimental Investigation of Sub-aperture Spacing Effects on Scintillation Suppression in Multi-aperture Free-space Optical Communication under Atmospheric Turbulence
    Shutong Liu, Baoqun Li, haiying jiang +6
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
BibTeX
@misc{krishna2026experimental,
  title = {{Experimental Investigation of Heat Transfer in Axisymmetric Open Cavities at Hypersonic Speeds}},
  author = {T. V. Krishna and J. Cohen and S. K. Karthick and Soumya R. Nanda},
  howpublished = {arXiv},
  year = {2026},
  month = nov,
  doi = {10.48550/arxiv.2611.14297},
  eprint = {2611.14297},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.14297},
}
RIS
TY  - UNPB
TI  - Experimental Investigation of Heat Transfer in Axisymmetric Open Cavities at Hypersonic Speeds
AU  - T. V. Krishna
AU  - J. Cohen
AU  - S. K. Karthick
AU  - Soumya R. Nanda
PY  - 2026
DA  - 2026/11/10
PB  - arXiv
DO  - 10.48550/arxiv.2611.14297
UR  - https://arxiv.org/abs/2611.14297
AB  - An experimental investigation was conducted to characterize the heat-transfer behavior of an axisymmetric cavity mounted on a cone with a semi-apex angle of (48^∘) under Mach 6 freestream conditions in a Ludwieg tunnel. The effects of cavity geometry, represented by the length-to-depth ratio (L/D = 0.5, 1.0, 2.0, 4.0, and 6.0), rear-wall height-to-depth ratio (h/D = −0.25, 0, and 0.5), and Reynolds number (Re_D = 23000 − 74000) were systematically investigated. Flow-field characteristics and surface heat-transfer behavior were examined using schlieren and planar laser Rayleigh scattering visualization techniques, together with surface pressure and heat-transfer measurements. The results indicate that increasing the cavity length-to-depth ratio leads to a reduction in the downstream Stanton number (St_d). For the longest cavity L/D = 6, however, the downstream Stanton number was found to exceed the upstream value (St_u) indicating enhanced heat transfer in the region downstream of the cavity.
ER  -