Skip to content
DraconiticResearch
Search Sources API
203,948 studies31 sourcesUpdated 12 min ago
Peer-reviewedCC BY 4.0ACS Omega

Detection of Antipoly(ethylene glycol) IgM in Immune Serum by Oligo(ethylene glycol)-Conjugated Cello-oligosaccharide Assemblies

  1. 1Institute of Science Tokyo , , 2-12-1-H-121 Ookayama , Meguro-ku, ,
  2. 2Juntendo University , , 6-8-1 Hinode , , ,
  3. 3the Jikei University School of Medicine , , 163-1 Kashiwa-shita , , ,

Abstract

Adsorbing antibodies of interest onto solid supports displaying corresponding antigens is an efficient strategy for their subsequent purification and detection. We have previously demonstrated the potential of water-dispersible, antibiofouling, and designable cello-oligosaccharide assemblies for antibody detection via enzyme-linked immunosorbent assay (ELISA). However, whether antigen-conjugated cello-oligosaccharide assemblies can detect specific antibodies contained in immune serum remains unexplored. In this study, we demonstrate the utility of oligo(ethylene glycol) (OEG)-conjugated cello-oligosaccharide assemblies for detecting antipoly(ethylene glycol) (PEG) immunoglobulin M (IgM) in serum from immunized animals. Mouse sera containing anti-PEG IgMs, induced by immunogenic polymers, were utilized for evaluation. ELISA results revealed that anti-PEG IgMs in the serum with no heat-inactivation or depletion were successfully detected by cello-oligosaccharide assemblies displaying OEG chains with at least three repeating ethylene glycol units. ELISAs using a series of cello-oligosaccharide assemblies displaying OEG chains indicated that the conjugation rate of OEG chains influences anti-PEG IgM binding. Furthermore, increasing the serum concentration led to enhanced detection efficacy for anti-PEG IgM, likely due to the superior antibiofouling properties of the cello-oligosaccharide assemblies, which minimize nonspecific adsorption of serum proteins. The concentration of the assemblies also significantly influenced the detection efficacy. Additionally, 7 days after a single intravenous injection of OEG-conjugated cello-oligosaccharide assemblies without micrometer-scale aggregates, ELISA signals for IgMs against PEG chains, OEG chains, and cello-oligosaccharide moieties were comparable to those of saline-treated controls. These findings demonstrated that OEG-conjugated cello-oligosaccharide assemblies hold considerable potential for the detection of anti-PEG IgMs in immune serum with no heat-inactivation or depletion.

Related

  1. Cationic Phenylpyridine Labeling for Improved Oligosaccharide and Glycan Analysis by Capillary Electrophoresis with LED-Induced Fluorescence Detection
    Filip Dusa, Michal Gregus, Richard Cmelik +4
    ACS OmegaPeer-reviewedCC BY 4.0Full textGeneral chemistryCrossref
  2. Analysis of the Core Oligosaccharide of Aeromonas hydrophila (Chemotype III) Lipopolysaccharide Using Fast Atom Bombardment, Electrospray and Low Energy Tandem Mass Spectrometry
    Joseph Banoub, Emmanuel Gentil, Derek Shaw
    Journal of SpectroscopyPeer-reviewedCC BYFull text1 citedPhysical chemistryHAL
  3. Crystal structure of a class II UDP-glucose-hexose-1-phosphate uridylyltransferase from Bifidobacterium longum involved in human milk oligosaccharide metabolism
    M. Sato, C. Yamada, M. Nishimoto +2
    bioRxivPreprintCC BY-NC-NDFull textMaterials & polymersbioRxiv
  4. Antitumoral activities of λ‑carrageenan oligosaccharide- based nanoparticles
    Jennifer Saliba, Manon Porta Zapata, Claudia Miranda-Perez de Alejo +15
    Journal of NanobiotechnologyPeer-reviewedCC BY-NC-NDMaterials & polymersHAL
  5. Rheological Properties of Self-Assembled Monolayers Formed from Oxygen-to-Carbon-Substituted Oligo(ethylene oxide) Molecules
    Minoru Yoshimoto, Shigeru Kurosawa, Mutsuo Tanaka
    Journal of Oleo SciencePeer-reviewedLicence not statedFull textGeneral chemistryJ-STAGE
BibTeX
@article{sugiura2026detection,
  title = {{Detection of Antipoly(ethylene glycol) IgM in Immune Serum by Oligo(ethylene glycol)-Conjugated Cello-oligosaccharide Assemblies}},
  author = {Kai Sugiura and Yuuki Hata and Hiroshi Tanaka and Kouichi Shiraishi and Takeshi Serizawa},
  journal = {ACS Omega},
  year = {2026},
  month = nov,
  doi = {10.1021/acsomega.6c04925},
  url = {https://pubs.acs.org/acsodf/article/doi/10.1021/acsomega.6c04925/5466299/Detection-of-Antipoly-ethylene-glycol-IgM-in},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Detection of Antipoly(ethylene glycol) IgM in Immune Serum by Oligo(ethylene glycol)-Conjugated Cello-oligosaccharide Assemblies
AU  - Kai Sugiura
AU  - Yuuki Hata
AU  - Hiroshi Tanaka
AU  - Kouichi Shiraishi
AU  - Takeshi Serizawa
PY  - 2026
DA  - 2026/11/09
JO  - ACS Omega
DO  - 10.1021/acsomega.6c04925
UR  - https://pubs.acs.org/acsodf/article/doi/10.1021/acsomega.6c04925/5466299/Detection-of-Antipoly-ethylene-glycol-IgM-in
AB  - Adsorbing antibodies of interest onto solid supports displaying corresponding antigens is an efficient strategy for their subsequent purification and detection. We have previously demonstrated the potential of water-dispersible, antibiofouling, and designable cello-oligosaccharide assemblies for antibody detection via enzyme-linked immunosorbent assay (ELISA). However, whether antigen-conjugated cello-oligosaccharide assemblies can detect specific antibodies contained in immune serum remains unexplored. In this study, we demonstrate the utility of oligo(ethylene glycol) (OEG)-conjugated cello-oligosaccharide assemblies for detecting antipoly(ethylene glycol) (PEG) immunoglobulin M (IgM) in serum from immunized animals. Mouse sera containing anti-PEG IgMs, induced by immunogenic polymers, were utilized for evaluation. ELISA results revealed that anti-PEG IgMs in the serum with no heat-inactivation or depletion were successfully detected by cello-oligosaccharide assemblies displaying OEG chains with at least three repeating ethylene glycol units. ELISAs using a series of cello-oligosaccharide assemblies displaying OEG chains indicated that the conjugation rate of OEG chains influences anti-PEG IgM binding. Furthermore, increasing the serum concentration led to enhanced detection efficacy for anti-PEG IgM, likely due to the superior antibiofouling properties of the cello-oligosaccharide assemblies, which minimize nonspecific adsorption of serum proteins. The concentration of the assemblies also significantly influenced the detection efficacy. Additionally, 7 days after a single intravenous injection of OEG-conjugated cello-oligosaccharide assemblies without micrometer-scale aggregates, ELISA signals for IgMs against PEG chains, OEG chains, and cello-oligosaccharide moieties were comparable to those of saline-treated controls. These findings demonstrated that OEG-conjugated cello-oligosaccharide assemblies hold considerable potential for the detection of anti-PEG IgMs in immune serum with no heat-inactivation or depletion.
SN  - 2470-1343
ER  -