Constraints on the Origin of Universal 1/f2 Photon-Count Spectra at Baseband
Abstract
A series of 11.6-d-duration photon-counting experiments, employing a broad variety of light sources with different statistical properties and optical spectra, were carried out over a 1.5-yr period. All of the photon-count spectra at baseband followed a common 1/f2 form over the frequency range 1 × 10−6 leqslant f leqslant 5 × 10−4 Hz, corresponding to a timescale range $33$ min $ \leqslant T_f \leqslant 11.6$ d, where Tf ≡ 1/f. The lower and upper timescale limits were established by the photodetector noise floor and the duration of the individual experiments, respectively. Unlike ordinary Brownian motion, all of the measured photon-count sample paths exhibited irregular long-timescale fluctuations, with durations ranging from hours to days. It has been established that the photon-count spectra cannot plausibly be ascribed to fluctuations of the current, voltage, or temperature of the source or the detector, nor to technical sources of noise associated with the optical system or local environment. Although the physical origin of the photon-count fluctuations remains unresolved, several heterodox hypotheses are set forth. From a statistical point-of-view, the photon counts appear to follow a doubly stochastic Poisson process with a slowly varying random intensity. Analogous experiments that rely on ionizing radiation and direct-conversion solid-state radiation detectors are proposed.
Related
- Origin of geometric cohesion in nonconvex granular materials: Interplay between interdigitation and rotational constraints enhancing frictional stability
- A universal sector of 𝒩=1 class 𝒮 spectra
- Universal 1/f Noise in the Power Spectra of Energy Time-series in Solvated DNA Dynamics
- Beyond Antibunching: Photon Correlation Analysis Reveals Blinking Origin
- Universal Dynamics of a Spin-3/2 Fermi Gas in Traps with Distinct Spectra
BibTeX
@misc{teich2026constraints,
title = {{Constraints on the Origin of Universal $1/f^2$ Photon-Count Spectra at Baseband}},
author = {Malvin Carl Teich and Steven B. Lowen},
howpublished = {arXiv},
year = {2026},
month = oct,
doi = {10.48550/arxiv.2610.05667},
eprint = {2610.05667},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2610.05667},
}
RIS
TY - UNPB
TI - Constraints on the Origin of Universal 1/f^2 Photon-Count Spectra at Baseband
AU - Malvin Carl Teich
AU - Steven B. Lowen
PY - 2026
DA - 2026/10/05
PB - arXiv
DO - 10.48550/arxiv.2610.05667
UR - https://arxiv.org/abs/2610.05667
AB - A series of 11.6-d-duration photon-counting experiments, employing a broad variety of light sources with different statistical properties and optical spectra, were carried out over a 1.5-yr period. All of the photon-count spectra at baseband followed a common 1/f^2 form over the frequency range 1 × 10^−6 leqslant f leqslant 5 × 10^−4 Hz, corresponding to a timescale range $33$ min $ \leqslant T_f \leqslant 11.6$ d, where T_f ≡ 1/f. The lower and upper timescale limits were established by the photodetector noise floor and the duration of the individual experiments, respectively. Unlike ordinary Brownian motion, all of the measured photon-count sample paths exhibited irregular long-timescale fluctuations, with durations ranging from hours to days. It has been established that the photon-count spectra cannot plausibly be ascribed to fluctuations of the current, voltage, or temperature of the source or the detector, nor to technical sources of noise associated with the optical system or local environment. Although the physical origin of the photon-count fluctuations remains unresolved, several heterodox hypotheses are set forth. From a statistical point-of-view, the photon counts appear to follow a doubly stochastic Poisson process with a slowly varying random intensity. Analogous experiments that rely on ionizing radiation and direct-conversion solid-state radiation detectors are proposed.
ER -