Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 41 min ago
PreprintCC BY 4.0HAL

Flux jump correction in the QUBIC TES data pipeline

11 more authors

Abstract

Flux jumps occur in the readout electronics of Transition Edge Sensor (TES) detectors coupled to Superconducting Quantum Interference Devices (SQUIDs), as a consequence of the periodic transfer function of SQUIDs in the superconducting regime. These events manifest as discontinuities in the Time Ordered Data (TOD) and can significantly degrade the quality of the measured signals. In this work, we present an automated pipeline to identify and correct flux jumps in the calibration data of the QUBIC (Q \& U Bolometric Interferometer for Cosmology) instrument, designed to measure the B-mode polarization of the Cosmic Microwave Background (CMB). Using data from multiple observation campaigns, we characterize the statistical properties of flux jumps and compare them with expectations based on the electronic configuration of the instrument. The proposed pipeline successfully corrects these events, allowing the recovery of affected data and enabling their use in subsequent CMB analysis.

Related

  1. A Delayed Rejection Reversible Jump Markov Chain Monte Carlo Method for Multi-Resolution Maps of the Stochastic Gravitational Wave Background with Pulsar Timing Array Data
    Taha T. Moursy, Nihan S. Pol
    arXivPreprintCC BY 4.0Full textHigh-energy astrophysicsInstrumentation & methodsarXiv
  2. Cosmological lensing as a jump process
    Galymzhan Baltabay, Ville Vaskonen
    arXivPreprintCC BY 4.0Full textCosmologyarXiv
  3. CtaAgnVar : a Pipeline for Variability Studies with the Cherenkov Telescope Array Observatory
    G Grolleron, J.-P Lenain, J Biteau +2
    HALPreprintLicence not statedGeneral astronomyGeneral physicsHAL
  4. meer21cm: an Analysis Pipeline and Comprehensive Toolkit for HI Intensity Mapping
    Zhaoting Chen, Steven Cunnington, Daniel Tassie +23
    HALPreprintLicence not statedGeneral astronomyApplied physics & instrumentationHAL
  5. Interferometric Survey of Stellar Parameters: Limb darkening study with the Pipeline for Interferometric Measurements of Stars
    N. Ebrahimkutty, D. Mourard, P. Berio +21
    Astronomy & AstrophysicsPeer-reviewedPublisher termsSolar & stellar physicsCrossref
BibTeX
@misc{costanza2026flux,
  title = {{Flux jump correction in the QUBIC TES data pipeline}},
  author = {Belen Costanza and Lucas Merlo Azzolina and Claudia G Scoccola and Nahuel Miron Granese and Elia Battistelli and Jean-Christophe Hamilton and Michel Piat and Damien Prele and Steve Torchinsky and Ismail Bekkaoui and Alessandro Coppolecchia and Paolo de Bernardis and Sofia Ferazzoli and Massimo Gervasi and Luca Gomez and Sabrina Marwede and Silvia Masi and Youssef Moulane and Alessandro Paiella and Mathias Regnier and Gustavo Romero and Federico Sanchez and Ivan Queirolo},
  howpublished = {HAL},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.00249},
  eprint = {2609.00249},
  archivePrefix = {arXiv},
  url = {https://hal.science/hal-05741425v1},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Flux jump correction in the QUBIC TES data pipeline
AU  - Belen Costanza
AU  - Lucas Merlo Azzolina
AU  - Claudia G Scoccola
AU  - Nahuel Miron Granese
AU  - Elia Battistelli
AU  - Jean-Christophe Hamilton
AU  - Michel Piat
AU  - Damien Prele
AU  - Steve Torchinsky
AU  - Ismail Bekkaoui
AU  - Alessandro Coppolecchia
AU  - Paolo de Bernardis
AU  - Sofia Ferazzoli
AU  - Massimo Gervasi
AU  - Luca Gomez
AU  - Sabrina Marwede
AU  - Silvia Masi
AU  - Youssef Moulane
AU  - Alessandro Paiella
AU  - Mathias Regnier
AU  - Gustavo Romero
AU  - Federico Sanchez
AU  - Ivan Queirolo
PY  - 2026
DA  - 2026/09/01
PB  - HAL
DO  - 10.48550/arxiv.2609.00249
UR  - https://hal.science/hal-05741425v1
AB  - Flux jumps occur in the readout electronics of Transition Edge Sensor (TES) detectors coupled to Superconducting Quantum Interference Devices (SQUIDs), as a consequence of the periodic transfer function of SQUIDs in the superconducting regime. These events manifest as discontinuities in the Time Ordered Data (TOD) and can significantly degrade the quality of the measured signals. In this work, we present an automated pipeline to identify and correct flux jumps in the calibration data of the QUBIC (Q \& U Bolometric Interferometer for Cosmology) instrument, designed to measure the B-mode polarization of the Cosmic Microwave Background (CMB). Using data from multiple observation campaigns, we characterize the statistical properties of flux jumps and compare them with expectations based on the electronic configuration of the instrument. The proposed pipeline successfully corrects these events, allowing the recovery of affected data and enabling their use in subsequent CMB analysis.
ER  -