Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 4 min ago
PreprintarXiv licencearXiv

Establishing an independent measurement traceability for 60-Co Air Kerma

Abstract

An independent air kerma traceability chain for 60Co radiation protection levels has been successfully established at the CIEMAT Ionizing Radiation Metrology Laboratory (LMRI-CIEMAT), based on the reference provided by the 137Cs primary standard. To achieve this, a secondary standard ionization chamber with an appropriate energy response was characterized, and its beam-quality correction factor, kQ, was accurately determined via Monte Carlo simulations using the EGSnrc code. The method's accuracy was validated through a comparison with long-term historical calibration data and peer-confirmed through CIEMAT's successful participation in the EURAMET.RI(I)-S19 supplementary comparison, recently officially published in the BIPM KCDB. The excellent agreement achieved with international reference values demonstrates the high robustness and traceability independence of this newly implemented methodology.

Versions

Related

  1. Method for Meteorological Optical Range Measurement Traceability Based on Programmable Spectral Shaping
    Taiyang Ren, Yu Zhang, Jian Zhang +9
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  2. Model-independent measurement of the transversity amplitudes of the B0→ K*0μ+μ- decay
    Roel Aaij, Mohammed Abdelfatah, Ahmed Sameh Wagih Abdelmotteleb +1,178
    HALPreprintLicence not statedHigh-energy & particle physicsHAL
  3. Semi-Device-Independent Certification of multi-qubit Entangled Basis Measurement
    Rajat Pandey, Alok Kumar Pan
    arXivPreprintCC BY 4.0Full textQuantum physics & quantum informationarXiv
  4. Dalitz plot binning optimization for the model-independent measurement of the CKM angle β with B0 → D π+ π-, D → KS0 π+ π- decays
    Anfeng Li, Wenbin Qian, Boan Shi +2
    arXivPreprintCC BY 4.0Full textHigh-energy & particle physicsarXiv
  5. Phase Independent Measurement of Weak Coherent Optical Signals
    Lani Chastain, Priya Drashni, Mahadeva Chanda Durjoy +3
    arXivPreprintarXiv licenceFull textQuantum physics & quantum informationarXiv
BibTeX
@misc{cornejodiaz2026establishing,
  title = {{Establishing an independent measurement traceability for 60-Co Air Kerma}},
  author = {Néstor Cornejo-Díaz and Cristina García-Mulas and Paz Aviés-Lucas},
  howpublished = {arXiv},
  year = {2026},
  month = jul,
  doi = {10.48550/arxiv.2607.27875},
  eprint = {2607.27875},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2607.27875},
}
RIS
TY  - UNPB
TI  - Establishing an independent measurement traceability for 60-Co Air Kerma
AU  - Néstor Cornejo-Díaz
AU  - Cristina García-Mulas
AU  - Paz Aviés-Lucas
PY  - 2026
DA  - 2026/07/30
PB  - arXiv
DO  - 10.48550/arxiv.2607.27875
UR  - https://arxiv.org/abs/2607.27875
AB  - An independent air kerma traceability chain for ^60Co radiation protection levels has been successfully established at the CIEMAT Ionizing Radiation Metrology Laboratory (LMRI-CIEMAT), based on the reference provided by the ^137Cs primary standard. To achieve this, a secondary standard ionization chamber with an appropriate energy response was characterized, and its beam-quality correction factor, k_Q, was accurately determined via Monte Carlo simulations using the EGSnrc code. The method's accuracy was validated through a comparison with long-term historical calibration data and peer-confirmed through CIEMAT's successful participation in the EURAMET.RI(I)-S19 supplementary comparison, recently officially published in the BIPM KCDB. The excellent agreement achieved with international reference values demonstrates the high robustness and traceability independence of this newly implemented methodology.
ER  -