Safety and feasibility of a balloon-based pulsed field ablation system for the catheter ablation of paroxysmal atrial fibrillation

  1. 1TEDA International Cardiovascular Hospital, Tianjin, China

Abstract

Aims: Pulsed field ablation (PFA) is a ablation modality that is increasingly used for pulmonary vein isolation (PVI) in atrial fibrillation (AF) patients. This study assessed the safety and effectiveness of a balloon-based PFA system at 6 months after treatment.

Methods and results: This study is a prospective, single-center, premarket study. A total of 56 patients with drug-refractory paroxysmal atrial fibrillation (PAF) were enrolled between November 2024 and September 2025 and underwent PVI with a balloon-based PFA system. The study endpoints were the rate of primary serious adverse events, acute procedural effectiveness and 6-month freedom from recurrence. Acute effectiveness was achieved in 100% (231/231) of the treated PVs (100% of patients, 56/56), with 33 ± 5.5 PFA applications/patient. The procedure, fluoroscopy, and transpired ablation times were 89.0 ± 30.7, 24.2 ± 8.3, and 20.0 ± 12.0 min, respectively. One (1.8%; 1/56) primary serious adverse event occurred: one patient developed intraoperative gastrointestinal bleeding due to TEE-induced mechanical injury. One patient developed a cerebral infarction on postoperative Day 28. The rate of freedom from documented atrial arrhythmias was 92.9% through 6 months after the index procedure.

Conclusion: The primary results of this study demonstrate the safety and effectiveness of the balloon-based PFA system for performing PVI in patients with PAF.

Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1007/s10840-026-02417-4.

Related

  1. Differential Recurrence Risk in Paroxysmal Versus Persistent Atrial Fibrillation Post-Catheter Ablation: HFpEF as an Independent Predictor.
    Xuesheng Fan, Yan Dong, Qiushi Chen +4
    Journal of cardiovascular development and diseasePeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  2. Unipolar electrogram-guided vs. ablation index-guided high-power short-duration pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a single-center randomized controlled trial
    Wei-Wei Wang, Si-Qi Li, Hui-Zhong Lin +5
    Quantitative imaging in medicine and surgeryPeer-reviewedCC BY-NC-NDFull textMedical imaging & radiologyEurope PMC
  3. Clinical validation of a novel catheter–tissue contact algorithm in atrial fibrillation ablation using pulsed field ablation
    Ankur Shah, Saanvi Billakanty, Andrew E. Volio +10
    Heart rhythm O2Peer-reviewedCC BY-NC-NDFull textCardiovascular medicineEurope PMC
  4. Predictive Value of Left Atrial Strain Combined with Low-Voltage Substrate for Recurrence After Radiofrequency Catheter Ablation in Persistent Atrial Fibrillation
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Radiofrequency ablation with a conventional solid tip catheter in contact with an implantable cardioverter-defibrillator coil causing inadvertent ventricular fibrillation.
    Michael R Manogue
    HeartRhythm case reportsPeer-reviewedCC BY-NC-NDFull textCardiovascular medicineEurope PMC
BibTeX
@article{wang2026safety,
  title = {{Safety and feasibility of a balloon-based pulsed field ablation system for the catheter ablation of paroxysmal atrial fibrillation}},
  author = {Peize Wang and Kun Zhang and Jinlong Bai and Xiuhong Dong and Shuai Yang and Lichao Tian and Zhaoqian Zhang and Zhi Li and Yuhao Miao and Jingjing Liu},
  journal = {Journal of Interventional Cardiac Electrophysiology},
  year = {2026},
  month = aug,
  doi = {10.1007/s10840-026-02417-4},
  url = {https://doi.org/10.1007/s10840-026-02417-4},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Safety and feasibility of a balloon-based pulsed field ablation system for the catheter ablation of paroxysmal atrial fibrillation
AU  - Peize Wang
AU  - Kun Zhang
AU  - Jinlong Bai
AU  - Xiuhong Dong
AU  - Shuai Yang
AU  - Lichao Tian
AU  - Zhaoqian Zhang
AU  - Zhi Li
AU  - Yuhao Miao
AU  - Jingjing Liu
PY  - 2026
DA  - 2026/08/19
JO  - Journal of Interventional Cardiac Electrophysiology
DO  - 10.1007/s10840-026-02417-4
UR  - https://doi.org/10.1007/s10840-026-02417-4
AB  - Aims: Pulsed field ablation (PFA) is a ablation modality that is increasingly used for pulmonary vein isolation (PVI) in atrial fibrillation (AF) patients. This study assessed the safety and effectiveness of a balloon-based PFA system at 6 months after treatment.  Methods and results: This study is a prospective, single-center, premarket study. A total of 56 patients with drug-refractory paroxysmal atrial fibrillation (PAF) were enrolled between November 2024 and September 2025 and underwent PVI with a balloon-based PFA system. The study endpoints were the rate of primary serious adverse events, acute procedural effectiveness and 6-month freedom from recurrence. Acute effectiveness was achieved in 100% (231/231) of the treated PVs (100% of patients, 56/56), with 33 ± 5.5 PFA applications/patient. The procedure, fluoroscopy, and transpired ablation times were 89.0 ± 30.7, 24.2 ± 8.3, and 20.0 ± 12.0 min, respectively. One (1.8%; 1/56) primary serious adverse event occurred: one patient developed intraoperative gastrointestinal bleeding due to TEE-induced mechanical injury. One patient developed a cerebral infarction on postoperative Day 28. The rate of freedom from documented atrial arrhythmias was 92.9% through 6 months after the index procedure.  Conclusion: The primary results of this study demonstrate the safety and effectiveness of the balloon-based PFA system for performing PVI in patients with PAF.  Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1007/s10840-026-02417-4.
SN  - 1383-875X
SN  - 1572-8595
ER  -