Exercise modality influences oxygen pulse flattening during incremental cardiopulmonary exercise testing in healthy adults
5 affiliations
- 1Pediatric Cardiology unit, Padeh Medical Center, Poriya, Israel
- 2Department of Physical Therapy, Faculty of Social Welfare and Health Science, University of Haifa, Haifa, Israel
- 3Pediatric Cardiology Institute, Ruth Children’s Hospital, Rambam Health Care Campus, Haifa, Israel
- 4Pediatric Pulmonary Institute, Ruth Children’s Hospital, Rambam Health Care Campus, Haifa, Israel
- 5The Technion Faculty of Medicine, Haifa, Israel
Abstract
Purpose: To compare oxygen pulse (O₂P) responses during cardiopulmonary exercise testing (CPET) in healthy adults using two ergometers, Treadmill and Cycle ergometer, and to determine the prevalence of O₂P flattening and the modality-specific characteristics of O₂P curve dynamics.
Methods: Thirty-four healthy adults (29.4 ± 6.9 years; 35% female) completed two maximal CPETs on both Cycle and Treadmill, in a random order within three weeks. O₂P flattening, defined as the absence of a further increase in O₂P despite increasing workload, was assessed visually and confirmed quantitatively.
Results: Twelve participants (35%) demonstrated O₂P flattening or decline, nine (27%) exclusively during Treadmill testing. A significant group × modality interaction was observed for peak O₂P (p < 0.05), with lower values in participants with flattening than in those showing a continuous rise. (Cycle: 9.9 ± 3.2 vs. 13.6 ± 2.7 ml/min/beat; Treadmill: 11.8 ± 3.7 vs. 16.6 ± 3.7 ml/min/beat). In addition, an O2P of ≤ 12.8 ml/beat on the Cycle increased the likelihood of flattening during maximal Treadmill exercise by 7.5 times (OR 7.5, p = 0.03).
Conclusion: O₂P flattening was more frequently observed during treadmill exercise, indicating that O₂P trajectories are exercise modality dependent. In individuals with low peak O₂P during cycle ergometry, additional assessment using treadmill CPET may offer complementary information.
Related
- Does Cardiopulmonary Exercise Testing Change Pulmonary Rehabilitation Decisions in COPD? A Critical Review of Incremental Clinical Utility
- Cardiopulmonary Exercise Testing in Preoperative Assessment: From Exercise Physiology to Personalized Perioperative Care
- Cardiopulmonary exercise testing utilization and clinical outcomes among patients with heart failure across racial and ethnic groups
- Cardiopulmonary Exercise Testing in Patients with Cardiac Pacemakers: From Device Optimization to Individualized Cardiac Rehabilitation
- Dynamic graph vector autoregression for characterizing cardiac electromechanical dynamics during incremental exercise from the joint phase space of electrocardiogram and phonocardiogram
BibTeX
@article{mainzer2026exercise,
title = {{Exercise modality influences oxygen pulse flattening during incremental cardiopulmonary exercise testing in healthy adults}},
author = {Gur Mainzer and Faris Khourey and Merav Zucker-Toledano and Ronen Bar-Yoseph and Einat Kodesh},
journal = {European Journal of Applied Physiology},
year = {2026},
month = sep,
doi = {10.1007/s00421-026-06437-w},
url = {https://doi.org/10.1007/s00421-026-06437-w},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Exercise modality influences oxygen pulse flattening during incremental cardiopulmonary exercise testing in healthy adults
AU - Gur Mainzer
AU - Faris Khourey
AU - Merav Zucker-Toledano
AU - Ronen Bar-Yoseph
AU - Einat Kodesh
PY - 2026
DA - 2026/09/28
JO - European Journal of Applied Physiology
DO - 10.1007/s00421-026-06437-w
UR - https://doi.org/10.1007/s00421-026-06437-w
AB - Purpose: To compare oxygen pulse (O₂P) responses during cardiopulmonary exercise testing (CPET) in healthy adults using two ergometers, Treadmill and Cycle ergometer, and to determine the prevalence of O₂P flattening and the modality-specific characteristics of O₂P curve dynamics. Methods: Thirty-four healthy adults (29.4 ± 6.9 years; 35% female) completed two maximal CPETs on both Cycle and Treadmill, in a random order within three weeks. O₂P flattening, defined as the absence of a further increase in O₂P despite increasing workload, was assessed visually and confirmed quantitatively. Results: Twelve participants (35%) demonstrated O₂P flattening or decline, nine (27%) exclusively during Treadmill testing. A significant group × modality interaction was observed for peak O₂P (p < 0.05), with lower values in participants with flattening than in those showing a continuous rise. (Cycle: 9.9 ± 3.2 vs. 13.6 ± 2.7 ml/min/beat; Treadmill: 11.8 ± 3.7 vs. 16.6 ± 3.7 ml/min/beat). In addition, an O2P of ≤ 12.8 ml/beat on the Cycle increased the likelihood of flattening during maximal Treadmill exercise by 7.5 times (OR 7.5, p = 0.03). Conclusion: O₂P flattening was more frequently observed during treadmill exercise, indicating that O₂P trajectories are exercise modality dependent. In individuals with low peak O₂P during cycle ergometry, additional assessment using treadmill CPET may offer complementary information.
SN - 1439-6319
SN - 1439-6327
ER -