Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 58 min ago
PreprintarXiv licencearXiv

On-Orbit Calibration of Danuri/PolCam. II. Image Artifact Correction

Abstract

Danuri, South Korea's first lunar orbiter, was launched on 2022 August 5, and has completed its two-year nominal mission phase. The wide-angle Polarimetric Camera (PolCam) onboard Danuri is the first instrument to conduct global polarimetric observations from lunar orbit. This paper presents the image artifact correction pipeline for PolCam's on-orbit data. It encompasses the primary steps of the radiometric calibration, consisting of dark current removal, smear correction, and flat-fielding, except for inter-channel relative response and the final radiance calculation. Notably, PolCam's raw data exhibit severe smear artifacts induced by the frame-transfer CCD architecture, which degrade both radiometric fidelity and the accuracy of polarimetric measurements. These smear artifacts have been mitigated through a rigorous correction algorithm, restoring data quality to a level sufficient for scientific analysis and facilitating the precise derivation of the degree of linear polarization. These steps serve as an essential prerequisite for conducting subsequent absolute radiance and photometric calibrations. Finally, we present representative examples of polarimetric measurements to validate the calibration performance. Although the current calibration focuses on restoring data quality for qualitative scientific analysis, these results demonstrate the expected inverse linear relationship between intensity and polarization.

Versions

Related

  1. A heteroskedasticity and autocorrelation consistent test for process noise calibration of Kalman filters in multi-sensor orbit determination
    Antonio Malaver, Jose M. Montilla, Rafael Vazquez
    arXivPreprintCC BY-NC-ND 4.0Full textSolar & stellar physicsarXiv
  2. Uber-calibration-based Two-level Radial-velocity Zero-point Correction for APOGEE
    Jinming Zhang, Haibo Yuan, Zhijia Tian
    arXivPreprintarXiv licenceFull textGalaxiesInstrumentation & methodsarXiv
  3. The SPHEREx Instrument: Calibration, Testing, and Performance Measurements of the Near-infrared Spectroscopic Surveyor from the Laboratory to In-orbit Commissioning
    Phil M. Korngut, James J. Bock, Samuel Condon +90
    The Astrophysical Journal Supplement SeriesPeer-reviewedCC BY 4.0Full textSolar & stellar physicsCrossref
  4. The shell around VY Canis Majoris in SPHEREx is likely an artifact
    Viraj Karambelkar, Yashvi Sharma, Kishalay De
    arXivPreprintCC BY 4.0Full textInstrumentation & methodsarXiv
  5. “Mega-Earths” are Likely an Artifact of Stellar Activity
    Casey L. Brinkman, Nicolas B. Cowan
    The Astrophysical Journal LettersPeer-reviewedCC BY 4.0Full textSolar & stellar physicsIOP/AASCrossref
BibTeX
@misc{baek2026onorbit,
  title = {{On-Orbit Calibration of Danuri/PolCam. II. Image Artifact Correction}},
  author = {Kilho Baek and Sungsoo S. Kim and Minsup Jeong and Young-Jun Choi},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2607.08008},
  eprint = {2607.08008},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2607.08008},
}
RIS
TY  - UNPB
TI  - On-Orbit Calibration of Danuri/PolCam. II. Image Artifact Correction
AU  - Kilho Baek
AU  - Sungsoo S. Kim
AU  - Minsup Jeong
AU  - Young-Jun Choi
PY  - 2026
DA  - 2026/09/29
PB  - arXiv
DO  - 10.48550/arxiv.2607.08008
UR  - https://arxiv.org/abs/2607.08008
AB  - Danuri, South Korea's first lunar orbiter, was launched on 2022 August 5, and has completed its two-year nominal mission phase. The wide-angle Polarimetric Camera (PolCam) onboard Danuri is the first instrument to conduct global polarimetric observations from lunar orbit. This paper presents the image artifact correction pipeline for PolCam's on-orbit data. It encompasses the primary steps of the radiometric calibration, consisting of dark current removal, smear correction, and flat-fielding, except for inter-channel relative response and the final radiance calculation. Notably, PolCam's raw data exhibit severe smear artifacts induced by the frame-transfer CCD architecture, which degrade both radiometric fidelity and the accuracy of polarimetric measurements. These smear artifacts have been mitigated through a rigorous correction algorithm, restoring data quality to a level sufficient for scientific analysis and facilitating the precise derivation of the degree of linear polarization. These steps serve as an essential prerequisite for conducting subsequent absolute radiance and photometric calibrations. Finally, we present representative examples of polarimetric measurements to validate the calibration performance. Although the current calibration focuses on restoring data quality for qualitative scientific analysis, these results demonstrate the expected inverse linear relationship between intensity and polarization.
ER  -