Pump quantization changes optimal measurements for quantum sensing
Abstract
Standard analyses of quantum phase sensing often neglect the overhead of generating squeezed-light by treating the pump as an undepleted classical resource. Realistically, the pump is a quantum object that undergoes significant depletion and entangles with the produced squeezed light, raising the question of how the crossover from a classical to a quantum pump limits the quantum advantage in sensing. Contrary to prior analyses, we show that quantum advantage persists despite pump quantization, but depends critically on the nonlinear (χ(2)) source dynamics. In particular, we demonstrate that Heisenberg scaling emerges in the regime of strong pump depletion, rather than maximum signal squeezing. At maximum squeezing, the quantum Fisher information (QFI) for interferometric sensing of an unknown phase scales as N3/2, where N is the pump photon number, surpassing the shot-noise limit but establishing that squeezing itself is insufficient to attain Heisenberg scaling of N2. At maximal pump depletion, where the signal flux is maximized, the QFI scales as N2. In this regime, standard photon counting is suboptimal, while a joint nonlinear measurement of the entire pump-signal system is shown to achieve Heisenberg scaling. Our work shows that pump quantization changes both the optimal operating point and the measurement strategies required to preserve a realistic quantum advantage in phase estimation and, more broadly, many-body quantum dynamics.
Related
- Beyond Shor's Conjecture: Optimal Quantum Measurements at Fixed Error
- Stabilizing temporal quantum-enhanced sensitivity via sub-optimal measurements
- Bell State Analysis Provides an Optimal Basis Saturating the Quantum Cramer-Rao in Rotation Sensing
- Optimal Low-Rank Quantum State Tomography with Bounded-Sample Joint Measurements
- Geometric construction of optimal probe states in distributed multiparameter quantum sensing
BibTeX
@misc{wadood2026pump,
title = {{Pump quantization changes optimal measurements for quantum sensing}},
author = {S. A. Wadood and L. Bello and T. Ilias and J. W. Fleischer},
howpublished = {arXiv},
year = {2026},
month = nov,
doi = {10.48550/arxiv.2611.03943},
eprint = {2611.03943},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2611.03943},
note = {CC BY 4.0},
}
RIS
TY - UNPB
TI - Pump quantization changes optimal measurements for quantum sensing
AU - S. A. Wadood
AU - L. Bello
AU - T. Ilias
AU - J. W. Fleischer
PY - 2026
DA - 2026/11/02
PB - arXiv
DO - 10.48550/arxiv.2611.03943
UR - https://arxiv.org/abs/2611.03943
AB - Standard analyses of quantum phase sensing often neglect the overhead of generating squeezed-light by treating the pump as an undepleted classical resource. Realistically, the pump is a quantum object that undergoes significant depletion and entangles with the produced squeezed light, raising the question of how the crossover from a classical to a quantum pump limits the quantum advantage in sensing. Contrary to prior analyses, we show that quantum advantage persists despite pump quantization, but depends critically on the nonlinear (χ^(2)) source dynamics. In particular, we demonstrate that Heisenberg scaling emerges in the regime of strong pump depletion, rather than maximum signal squeezing. At maximum squeezing, the quantum Fisher information (QFI) for interferometric sensing of an unknown phase scales as N^3/2, where N is the pump photon number, surpassing the shot-noise limit but establishing that squeezing itself is insufficient to attain Heisenberg scaling of N^2. At maximal pump depletion, where the signal flux is maximized, the QFI scales as N^2. In this regime, standard photon counting is suboptimal, while a joint nonlinear measurement of the entire pump-signal system is shown to achieve Heisenberg scaling. Our work shows that pump quantization changes both the optimal operating point and the measurement strategies required to preserve a realistic quantum advantage in phase estimation and, more broadly, many-body quantum dynamics.
ER -