Skip to content
DraconiticResearch
Search Sources API
277,308 studies31 sourcesUpdated 9 min ago
Peer-reviewedCC BY 3.0Pakistan Journal of Medical Sciences

Structured sterile pathway and reduced hospital-acquired infections in resource-constrained oncology care: A pre-post study

4 affiliations
  1. 1Zeeshan Ali, MD, MS Healthcare Management, Ittefaq Hospital Trust, Lahore, Pakistan
  2. 2Sehrish Zeeshan, MBBS, MCPS, Ittefaq Hospital Trust, Lahore, Pakistan
  3. 3Rabia Hayee, Pharm-D, M.Phil Oncology/Clinical Pharmacist, Ittefaq Hospital Trust, Lahore, Pakistan
  4. 4Habib Ullah Joiya, MBBS, M.Phil Community Medicine Pakistan Medical and Dental Council., Ittefaq Hospital Trust, Lahore, Pakistan

Abstract

Objectives:: To determine whether a four-component structured sterile pathway in combination with portable HEPA-plasmacluster devices with structured staff training, hand-hygiene auditing and PPE monitoring, is associated with improvement in protective-environment, air-quality parameters and reduction in hospital-associated infections (HAIs) in an oncology unit which lack facility of fixed HEPA infrastructure.

Methodology:: A single-center, pre-post quasi-experimental study was carried out at Ittefaq Hospital Trust, Lahore (January 2025 to December 2025). A four-component pathway was implemented in a seven-bed oncology unit: zone-based controls using portable Plasmacluster devices (True HEPA H13 plus ion-mediated inactivation), staff education, WHO Five Moments hand-hygiene auditing, and PPE monitoring. Phase one (n=142) used standard air-conditioned rooms without purification; Phase two (n=138) added the full pathway. The primary outcome was HAI rate per 1,000 patient-days (CDC/NHSN); air and surface colony counts were sampled on days 1, 7, 14, 30 and 60 of each phase.

Results:: Across 280 admissions, the HAI rate fell sharply from 8.4 to 2.6 per 1,000 patient-days a 69.0% reduction (RR 0.31, 95% CI 0.19–0.51; p<0.001). CLABSI fell from 3.2 to 0.8 per 1,000 line-days (p=0.003) and CAUTI from 2.1 to 1.1 (p=0.012). Mean air changes per hour rose from 5.2 to 13.8, meeting the ASHRAE 170-2021 minimum air-change threshold, and median PM2.5 fell from 44.8 to 7.3 µg/m3. Air and surface colony counts dropped by 89.1% and 91.5% (both p<0.001), with airborne Aspergillus eliminated by the second month.

Conclusions:: Implementation of the four-component sterile pathway was associated with attainment of the ASHRAE 170-2021 minimum air-change threshold, a 69% lower HAI rate and no recovery of clinically significant environmental pathogens, at a total implementation cost of US$2,030. Because the components were introduced together in an uncontrolled pre-post design, these findings support the pathway as a whole rather than any single component, and need confirmation in controlled studies.

Related

  1. Nurse staffing and hospital-acquired infections in the intensive care unit: A systematic review and meta-analysis
    Clarissa Jasmine Aurelia, Wendelin Alexia, Jacob Donald Tan
    Journal of Infection PreventionPeer-reviewedLicence not statedFull textInfectious diseasePMC
  2. Hospital-Acquired Infections Associated with Sepsis in Intensive Care Unit Patients: Clinical Characteristics, Antimicrobial Resistance, and Outcomes
    Alexandru Cristian Cindrea, Mădălin-Marius Margan, Adina Maria Marza +7
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Hidden labor, monitoring, and exit burdens after hospital operational AI deployment: implications for resource-constrained Chinese hospitals
    Xieyi Wang, Hezhuo Wang
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Association between hydrocortisone use and outcomes in sepsis patients with hospital-acquired bloodstream infections: An ancillary analysis of the EUROBACT-2 cohort
    Gary Duclos, Mohamed Boucekine, Alexis Tabah +8
    PLOS OnePeer-reviewedCC BY 4.0Full textPhysiologyPLOS
  5. Workflow and Clinical Outcomes After Implementation of a Structured Trauma Protocol in a Resource-Constrained Emergency Department: A Single-Center Retrospective Before-and-After Cohort Study
    Reşad Beyoğlu, Oğuz Küçükyılmaz
    HealthcarePeer-reviewedCC BY 4.0Full textGeneral medicinePMC
BibTeX
@article{ali2026structured,
  title = {{Structured sterile pathway and reduced hospital-acquired infections in resource-constrained oncology care: A pre-post study}},
  author = {Zeeshan Ali and Sehrish Zeeshan and Rabia Hayee and Habib Ullah Joiya},
  journal = {Pakistan Journal of Medical Sciences},
  year = {2026},
  month = nov,
  doi = {10.12669/pjms.42.10.19906},
  url = {https://doi.org/10.12669/pjms.42.10.19906},
  note = {CC BY 3.0},
}
RIS
TY  - JOUR
TI  - Structured sterile pathway and reduced hospital-acquired infections in resource-constrained oncology care: A pre-post study
AU  - Zeeshan Ali
AU  - Sehrish Zeeshan
AU  - Rabia Hayee
AU  - Habib Ullah Joiya
PY  - 2026
DA  - 2026/11/17
JO  - Pakistan Journal of Medical Sciences
DO  - 10.12669/pjms.42.10.19906
UR  - https://doi.org/10.12669/pjms.42.10.19906
AB  - Objectives:: To determine whether a four-component structured sterile pathway in combination with portable HEPA-plasmacluster devices with structured staff training, hand-hygiene auditing and PPE monitoring, is associated with improvement in protective-environment, air-quality parameters and reduction in hospital-associated infections (HAIs) in an oncology unit which lack facility of fixed HEPA infrastructure.  Methodology:: A single-center, pre-post quasi-experimental study was carried out at Ittefaq Hospital Trust, Lahore (January 2025 to December 2025). A four-component pathway was implemented in a seven-bed oncology unit: zone-based controls using portable Plasmacluster devices (True HEPA H13 plus ion-mediated inactivation), staff education, WHO Five Moments hand-hygiene auditing, and PPE monitoring. Phase one (n=142) used standard air-conditioned rooms without purification; Phase two (n=138) added the full pathway. The primary outcome was HAI rate per 1,000 patient-days (CDC/NHSN); air and surface colony counts were sampled on days 1, 7, 14, 30 and 60 of each phase.  Results:: Across 280 admissions, the HAI rate fell sharply from 8.4 to 2.6 per 1,000 patient-days a 69.0% reduction (RR 0.31, 95% CI 0.19–0.51; p<0.001). CLABSI fell from 3.2 to 0.8 per 1,000 line-days (p=0.003) and CAUTI from 2.1 to 1.1 (p=0.012). Mean air changes per hour rose from 5.2 to 13.8, meeting the ASHRAE 170-2021 minimum air-change threshold, and median PM2.5 fell from 44.8 to 7.3 µg/m3. Air and surface colony counts dropped by 89.1% and 91.5% (both p<0.001), with airborne Aspergillus eliminated by the second month.  Conclusions:: Implementation of the four-component sterile pathway was associated with attainment of the ASHRAE 170-2021 minimum air-change threshold, a 69% lower HAI rate and no recovery of clinically significant environmental pathogens, at a total implementation cost of US$2,030. Because the components were introduced together in an uncontrolled pre-post design, these findings support the pathway as a whole rather than any single component, and need confirmation in controlled studies.
SN  - 1682-024X
SN  - 1681-715X
ER  -