Artificial Intelligence Approaches for Gastrointestinal Bleeding Detection in Capsule Endoscopy: A Systematic Review and Critical Analysis
- 1Department of Biomedical Engineering, College of Engineering and Information Technology, Ajman University, Ajman P.O. Box 346, United Arab Emirates; (N.M.H.); (J.Z.R.)
Abstract
Background/Objectives: Gastrointestinal (GI) bleeding is a common, potentially life-threatening condition, and capsule endoscopy (CE) is the principal investigation for suspected small-bowel bleeding after non-diagnostic upper endoscopy and colonoscopy. Because manual review of thousands of CE frames is labor-intensive, artificial intelligence (AI) has been proposed to automate bleeding detection. Methods: Following PRISMA 2020, this systematic review synthesizes 15 peer-reviewed journal studies (2020–2025) applying traditional machine learning, convolutional neural networks, transfer learning, attention-based or hybrid architectures, segmentation, or object detection to GI bleeding detection in CE. Methodological quality was appraised with an AI-adapted risk-of-bias framework informed by QUADAS-2 and PROBAST. Results: Frame-level classification accuracy ranged from 90.6% to 99.9% (median 98.5%; 13 studies), with the lowest values from evaluations closest to clinical practice; the segmentation and detection studies reported a mean intersection-over-union of 86.9% and an [email protected] of 79.0%. Only two studies (13%) were at low risk of bias for validation strategy, none reported patient-level separation of training and test data, only four (27%) used clinical patient data, and none compared AI with conventional endoscopy or clinical outcomes. Conclusions: Current evidence demonstrates high performance on curated datasets but not yet generalizability or clinical readiness; patient-level, external, and prospective multicentre validation is required.
Related
- Artificial intelligence-based tongue image analysis for non-invasive screening of gastric cancer, precancerous lesions, and related gastrointestinal disorders: a systematic review
- Potential to improve early detection of lung cancer through expansion of focused and opportunistic screening approaches: a scoping review focusing on potential expansion of screening risk factors and adoption of artificial intelligence models.
- From underdiagnosis to scalable screening: Applications of artificial intelligence for vertebral compression fracture detection – a systematic review and meta-analysis of diagnostic performance
- Artificial intelligence for the detection and classification of occupational pneumoconioses: a systematic review
- Artificial intelligence in health insurance fraud detection: a global and regional systematic review
BibTeX
@article{helal2026artificial,
title = {{Artificial Intelligence Approaches for Gastrointestinal Bleeding Detection in Capsule Endoscopy: A Systematic Review and Critical Analysis}},
author = {Nasima Mohammad Helal and Jon Zaccary Regala and Mujeeb Rahman},
journal = {Diagnostics},
year = {2026},
month = oct,
doi = {10.3390/diagnostics16213449},
url = {https://doi.org/10.3390/diagnostics16213449},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Artificial Intelligence Approaches for Gastrointestinal Bleeding Detection in Capsule Endoscopy: A Systematic Review and Critical Analysis
AU - Nasima Mohammad Helal
AU - Jon Zaccary Regala
AU - Mujeeb Rahman
PY - 2026
DA - 2026/10/22
JO - Diagnostics
DO - 10.3390/diagnostics16213449
UR - https://doi.org/10.3390/diagnostics16213449
AB - Background/Objectives: Gastrointestinal (GI) bleeding is a common, potentially life-threatening condition, and capsule endoscopy (CE) is the principal investigation for suspected small-bowel bleeding after non-diagnostic upper endoscopy and colonoscopy. Because manual review of thousands of CE frames is labor-intensive, artificial intelligence (AI) has been proposed to automate bleeding detection. Methods: Following PRISMA 2020, this systematic review synthesizes 15 peer-reviewed journal studies (2020–2025) applying traditional machine learning, convolutional neural networks, transfer learning, attention-based or hybrid architectures, segmentation, or object detection to GI bleeding detection in CE. Methodological quality was appraised with an AI-adapted risk-of-bias framework informed by QUADAS-2 and PROBAST. Results: Frame-level classification accuracy ranged from 90.6% to 99.9% (median 98.5%; 13 studies), with the lowest values from evaluations closest to clinical practice; the segmentation and detection studies reported a mean intersection-over-union of 86.9% and an [email protected] of 79.0%. Only two studies (13%) were at low risk of bias for validation strategy, none reported patient-level separation of training and test data, only four (27%) used clinical patient data, and none compared AI with conventional endoscopy or clinical outcomes. Conclusions: Current evidence demonstrates high performance on curated datasets but not yet generalizability or clinical readiness; patient-level, external, and prospective multicentre validation is required.
SN - 2075-4418
ER -