Skip to content
DraconiticResearch
Search Sources API
194,161 studies31 sourcesUpdated 52 min ago
PreprintCC BY-NC-NDbioRxiv

Ultrasonic Detection of Venous Gas Emboli and Tissue Gas in Rodents: Toward Imaging Biomarkers for Decompression Stress

  1. 1The University of North Carolina at Chapel Hill

Abstract

Introduction In humans, decompression sickness (DCS) risk assessment often relies on surrogate ultrasound detection of venous gas emboli (VGE). Rodents are widely used to study DCS and mortality, yet no established relationship exists between imaging and decompression outcomes. We exposed rats to dives with differing DCS risk and investigated whether ultrasound measurements reflected modeled DCS risk and revealed tissue-level manifestations of decompression stress. Methods Rats underwent dry saturation exposures to 700 KPA in a hyperbaric chamber while breathing either heliox (low-risk; pDCS = 0.1%) or air (high-risk; pDCS = 13%), where pDCS was estimated using an existing rodent DCS risk model. Following decompression, animals were anesthetized for serial cardiac and renal ultrasound imaging. Echocardiograms were evaluated for VGE using an ordinal scale. The mean grayscale intensity (arbitrary units, a.u.) was also quantified in renal region of interest (ROI). In a separate set of animals, histopathology was conducted to evaluate renal manifestations. Results Observed peak VGE grades increased with estimated DCS risk, from grade 1 at pDCS 0.1% to grade 2 at pDCS 13%. Multi-organ analysis found lower renal ROI echogenicity during periods of high VGE, with mean grayscale intensities of 67.0 a.u. and 60.7 a.u. for VGE grades 0-1 and 2-4, respectively. Renal histopathology identified round voids consistent with pre-mortem gas emboli. Conclusions VGE burden tracked with pDCS risk. The decrease in renal image intensity during high VGE may indicate ultrasound attenuation from acoustic shadowing caused by excess tissue gas bubbles. These findings advance the development of physiologically relevant imaging biomarkers of decompression stress.

Related

  1. Millisecond-scale detection of mouse ultrasonic vocalizations enables closed-loop experiments
    A. Mohammadi, J. Tillmann, M. K. Schwarz
    bioRxivPreprintCC BYFull textNeurosciencebioRxiv
  2. Detection and characterisation of alpha- and betacoronaviruses in rodents and bats from Germany, France, Belgium and Ireland
    Elena Sgarabotto, Vinaya Venkat, Eda Altan +27
    HALPreprintCC BY 4.0Full textMicrobiologyHALbioRxiv
  3. Neuroinflammatory Imaging Biomarkers: Relevance to Multiple Sclerosis and its Therapy
    Thomas Tourdias, Vincent Dousset
    NeurotherapeuticsPeer-reviewedLicence not statedFull text30 citedNeuroscienceHAL
  4. Multimodal Magnetic Resonance Imaging Biomarkers of Pediatric Traumatic Brain Injury Identified by Ensemble Learning Are Associated with Psychopathology
    E. Martin, K. Wu, X. Li
    bioRxivPreprintAll rights reservedFull textNeurosciencebioRxiv
  5. TRP-Net: A Text-Guided Dual-Modal Network for Potato Leaf Lesion Detection Under Complex Imaging Conditions
    Plants (Basel, Switzerland)Peer-reviewedCC BYFull textPlant biologyEurope PMC
BibTeX
@misc{currens2026ultrasonic,
  title = {{Ultrasonic Detection of Venous Gas Emboli and Tissue Gas in Rodents: Toward Imaging Biomarkers for Decompression Stress}},
  author = {J. B. Currens and K. M. Eltz and R. S. Sellers and E. Dugrenot and V. Papadopoulou},
  howpublished = {bioRxiv},
  year = {2026},
  month = oct,
  doi = {10.64898/2026.10.26.761998},
  url = {https://www.biorxiv.org/content/10.64898/2026.10.26.761998v1},
  note = {CC BY-NC-ND},
}
RIS
TY  - UNPB
TI  - Ultrasonic Detection of Venous Gas Emboli and Tissue Gas in Rodents: Toward Imaging Biomarkers for Decompression Stress
AU  - J. B. Currens
AU  - K. M. Eltz
AU  - R. S. Sellers
AU  - E. Dugrenot
AU  - V. Papadopoulou
PY  - 2026
DA  - 2026/10/26
PB  - bioRxiv
DO  - 10.64898/2026.10.26.761998
UR  - https://www.biorxiv.org/content/10.64898/2026.10.26.761998v1
AB  - Introduction In humans, decompression sickness (DCS) risk assessment often relies on surrogate ultrasound detection of venous gas emboli (VGE). Rodents are widely used to study DCS and mortality, yet no established relationship exists between imaging and decompression outcomes. We exposed rats to dives with differing DCS risk and investigated whether ultrasound measurements reflected modeled DCS risk and revealed tissue-level manifestations of decompression stress. Methods Rats underwent dry saturation exposures to 700 KPA in a hyperbaric chamber while breathing either heliox (low-risk; pDCS = 0.1%) or air (high-risk; pDCS = 13%), where pDCS was estimated using an existing rodent DCS risk model. Following decompression, animals were anesthetized for serial cardiac and renal ultrasound imaging. Echocardiograms were evaluated for VGE using an ordinal scale. The mean grayscale intensity (arbitrary units, a.u.) was also quantified in renal region of interest (ROI). In a separate set of animals, histopathology was conducted to evaluate renal manifestations. Results Observed peak VGE grades increased with estimated DCS risk, from grade 1 at pDCS 0.1% to grade 2 at pDCS 13%. Multi-organ analysis found lower renal ROI echogenicity during periods of high VGE, with mean grayscale intensities of 67.0 a.u. and 60.7 a.u. for VGE grades 0-1 and 2-4, respectively. Renal histopathology identified round voids consistent with pre-mortem gas emboli. Conclusions VGE burden tracked with pDCS risk. The decrease in renal image intensity during high VGE may indicate ultrasound attenuation from acoustic shadowing caused by excess tissue gas bubbles. These findings advance the development of physiologically relevant imaging biomarkers of decompression stress.
ER  -