Tetrahedral DNA nanostructure–gated solution-phase CRISPR/Cas12a system for probe immobilization-free, reagent-efficient, and dual-phase electrochemical detection of circulating microRNAs in liquid biopsy
4 affiliations
- 1Department of Urology, Urology Research Institute, the First Affiliated Hospital, Fujian Medical University, Fuzhou, 350005 Fujian Province China
- 2Department of Urology, National Regional Medical Center, Binhai Campus of the First Affiliated Hospital, Fujian Medical University, Fuzhou, 350212 Fujian Province China
- 3Fujian Key Laboratory of Drug Target Discovery and Structural and Functional Research, School of Pharmacy, Fujian Medical University, Fuzhou, 350122 China
- 4Fujian Key Laboratory of Tumor Immunotherapy, the First Affiliated Hospital, Fujian Medical University, Fuzhou, 350005 China
Abstract
Liquid-biopsy nucleic acid biomarkers hold strong promise for non-invasive cancer diagnostics, yet their ultralow abundance presents substantial analytical challenges. Conventional electrochemical biosensors rely on complex probe immobilization, whereas emerging homogeneous strategies remain susceptible to matrix interference and require large reaction volumes. Here, we report a probe immobilization-free, reagent-efficient, dual-phase electrochemical platform that integrates solution-phase CRISPR/Cas12a reactions with a tetrahedral DNA nanostructure (TDN)–based interfacial gating mechanism for detecting circulating microRNAs. We found that TDNs extended with a thiolated blocking fragment (BF) impose a pronounced steric gating effect at the electrode–solution interface: the large, rigid TDN architecture prevents intact BF-linked structures from approaching the gold electrode, whereas smaller Cas12a-generated thiolated fragments readily assemble via Au–S interactions. This size-dependent gating transition switches the electrode from an HRP-accessible to an HRP-blocking state, producing a sharply resolved signal decrease that faithfully maps solution-phase cleavage onto an electrochemical readout. Using a target-competitive binding strategy to generate the activator DNA, this interfacial gating mechanism was developed into a robust dual-phase sensing platform driven by CRISPR/Cas12a. Because target recognition and Cas12a-mediated cleavage occur entirely in solution and only the final reaction products contact the electrode, the architecture retains high homogeneous reaction efficiency while avoiding diffusion-governed limitations and eliminating probe immobilization. The 10 µL reaction volume enables substantial reagent savings and strong compatibility with complex matrices. The assay achieves a detection limit of 4.1 aM and accurately quantifies renal cancer–associated circulating miRNA-21 in peripheral blood, yielding results fully consistent with RT-qPCR.
Graphical abstract:
Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1186/s12951-026-04936-8.
Related
- A syringe-based nanoliquid biopsy platform integrating magnetic immunocapture and electrochemical assay for circulating tumor cells enumeration and molecular profiling in NSCLC patients.
- Enzymatic confinement in lipidic mesophases and liquid-crystalline nanoparticles: from nanostructure to biocatalytic function
- An Enzyme-DNA Nanostructure with Enhanced Catalysis Accelerates MRSA Wound Healing
- Dye-affinity functionalized magnetic nanoparticles enable direct immobilization of cellulase from cell-free microbial culture medium
- Mild hyperbaric oxygen modulates selected proteolytic and mitochondrial markers during cast immobilization in mice
BibTeX
@article{chen2026tetrahedral,
title = {{Tetrahedral DNA nanostructure–gated solution-phase CRISPR/Cas12a system for probe immobilization-free, reagent-efficient, and dual-phase electrochemical detection of circulating microRNAs in liquid biopsy}},
author = {Shaohao Chen and Huajuan Ye and Bohan Lin and Dunhao Huang and Yang Chen and Ning Li and Junyang Zhuang and Yong Wei and Ning Xu},
journal = {Journal of Nanobiotechnology},
year = {2026},
month = aug,
doi = {10.1186/s12951-026-04936-8},
url = {https://doi.org/10.1186/s12951-026-04936-8},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Tetrahedral DNA nanostructure–gated solution-phase CRISPR/Cas12a system for probe immobilization-free, reagent-efficient, and dual-phase electrochemical detection of circulating microRNAs in liquid biopsy
AU - Shaohao Chen
AU - Huajuan Ye
AU - Bohan Lin
AU - Dunhao Huang
AU - Yang Chen
AU - Ning Li
AU - Junyang Zhuang
AU - Yong Wei
AU - Ning Xu
PY - 2026
DA - 2026/08/17
JO - Journal of Nanobiotechnology
DO - 10.1186/s12951-026-04936-8
UR - https://doi.org/10.1186/s12951-026-04936-8
AB - Liquid-biopsy nucleic acid biomarkers hold strong promise for non-invasive cancer diagnostics, yet their ultralow abundance presents substantial analytical challenges. Conventional electrochemical biosensors rely on complex probe immobilization, whereas emerging homogeneous strategies remain susceptible to matrix interference and require large reaction volumes. Here, we report a probe immobilization-free, reagent-efficient, dual-phase electrochemical platform that integrates solution-phase CRISPR/Cas12a reactions with a tetrahedral DNA nanostructure (TDN)–based interfacial gating mechanism for detecting circulating microRNAs. We found that TDNs extended with a thiolated blocking fragment (BF) impose a pronounced steric gating effect at the electrode–solution interface: the large, rigid TDN architecture prevents intact BF-linked structures from approaching the gold electrode, whereas smaller Cas12a-generated thiolated fragments readily assemble via Au–S interactions. This size-dependent gating transition switches the electrode from an HRP-accessible to an HRP-blocking state, producing a sharply resolved signal decrease that faithfully maps solution-phase cleavage onto an electrochemical readout. Using a target-competitive binding strategy to generate the activator DNA, this interfacial gating mechanism was developed into a robust dual-phase sensing platform driven by CRISPR/Cas12a. Because target recognition and Cas12a-mediated cleavage occur entirely in solution and only the final reaction products contact the electrode, the architecture retains high homogeneous reaction efficiency while avoiding diffusion-governed limitations and eliminating probe immobilization. The 10 µL reaction volume enables substantial reagent savings and strong compatibility with complex matrices. The assay achieves a detection limit of 4.1 aM and accurately quantifies renal cancer–associated circulating miRNA-21 in peripheral blood, yielding results fully consistent with RT-qPCR. Graphical abstract: Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1186/s12951-026-04936-8.
SN - 1477-3155
ER -