Skip to content
DraconiticResearch
Search Sources API
203,948 studies31 sourcesUpdated 29 min ago
Peer-reviewedCC BY 4.0Nmr in Biomedicine

Per‐Channel Complex B1+ Mapping for Parallel Transmit Ultra‐High Field MRI

  1. 1Wolfson Brain Imaging Centre University of Cambridge Cambridge UK

Abstract

Ultra‐high field (UHF, B0 ≥ 7 T) MRI provides substantial gains in signal‐to‐noise ratio, spatial resolution and contrast. Routine clinical deployment has been limited by challenges of transmit field (B1+) inhomogeneity and specific absorption rate (SAR). Parallel transmission (pTx) can mitigate these challenges but it requires per‐channel complex B1+ maps to design effective pTx pulses. We review established and emerging approaches to obtain these maps. We begin by summarising the underlying physical principles and theory. Then we describe methods for magnitude B1+ mapping such as actual flip‐angle imaging (AFI), saturation‐prepared B1+ mapping (e.g., satTFL) and dual refocusing echo acquisition mode (DREAM) that are the basis of widely‐applied per‐channel complex B1+ mapping methods, as well as methods of pedagogical and/or historical relevance. Next, we describe how relative B1+ mapping with low‐flip angle gradient‐recalled echo (GRE) scans can determine the relative phases (and relative magnitudes) of B1+ for each channel. We recap the important interferometric approach that is now widely used. We explain how magnitude and phase maps are combined into complex per‐channel B1+ maps. We discuss remaining arbitrary factors such as the position‐dependent transmit reference phase. We discuss recent practical implementations such as Sandwich TFL, 3DREAM, compressed‐sensing SA2RAGE and respiratory‐resolved B1+ mapping. We explore the workflow improvements that could accrue if per‐channel B1+ maps do not need to be acquired for every subject. This includes deep‐learning–based approaches to synthesize B1+ maps from the normal localiser scans, the universal pulses (UPs) approach to precalibrate pulses and variants such as standardised universal pulses (SUPs), Fast‐Online Customised (FOCUS) and machine‐learning online customisation. We hope to encourage greater openness and harmonisation of these critical calibration steps for parallel transmit pulse design. This will become increasingly important as 7‐T pTx MRI is adopted for multisite cross‐vendor clinical research studies and to deliver the full scientific potential of new extremely high field human MRIs.

Related

  1. Rationale and Design of a Parallel Randomized Trial of a DASH‐Enhanced Portfolio Diet With or Without Ultra‐Processed Plant Proteins for Blood Pressure and Other Cardiometabolic Risk Factors in Adults With Hypertension and Obesity: The Substitution of High With Low Ultra‐Processed Soy Protein Foods in a Guideline‐Based Diet Intervention on Cardiometabolic Health Trial
    Zeinab Houshialsadat, Gabrielle Viscardi, Antonio G. Rossi +19
    Journal of the American Heart AssociationPeer-reviewedCC BYFull textCardiovascular medicineCrossrefDOAJ
  2. Clinical significance of ultra-low-amplitude electrograms during lattice-tip atrial mapping.
    Akinobu Mizutani, Masato Okada, Mebae Mizutani +2
    HeartRhythm case reportsPeer-reviewedCC BY-NC-NDFull textCardiovascular medicineEurope PMC
  3. Ultra-sensitive Mapping of Cell-free DNA-derived Methylomes Reveals Brain-specific Epigenetic Alterations Implicated in Alzheimer Disease
    X. Cui, A. V. Beadell, S. Tasaki +8
    medRxivPreprintAll rights reservedFull textHuman geneticsmedRxivPMC
  4. Global research landscape and emerging frontiers of ultra-processed food intake and cardiometabolic health: a bibliometric and knowledge-mapping analysis (2015-2025).
    Tianao Chen, Ping Ni, Minxin Li +4
    Frontiers in nutritionPeer-reviewedCC BYFull textEpidemiology & public healthEurope PMC
  5. Exploring and Mapping Expert Views on the Mechanisms Contributing to Patients’ Demand for Low-Value Care: A Complex Systems Approach
    Gillroy R. L. Fraser, G. Ardine de Wit, Job van Exel +4
    International Journal of Health Policy and ManagementPeer-reviewedCC BY 4.0Full textEpidemiology & public healthPMC
BibTeX
@article{yuan2026perchannel,
  title = {{Per‐Channel Complex B1+ Mapping for Parallel Transmit Ultra‐High Field MRI}},
  author = {Ye Yuan and Jianxiang Chen and Christopher T. Rodgers},
  journal = {Nmr in Biomedicine},
  year = {2026},
  month = nov,
  doi = {10.1002/nbm.70425},
  url = {https://doi.org/10.1002/nbm.70425},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Per‐Channel Complex B1+ Mapping for Parallel Transmit Ultra‐High Field MRI
AU  - Ye Yuan
AU  - Jianxiang Chen
AU  - Christopher T. Rodgers
PY  - 2026
DA  - 2026/11/03
JO  - Nmr in Biomedicine
DO  - 10.1002/nbm.70425
UR  - https://doi.org/10.1002/nbm.70425
AB  - Ultra‐high field (UHF, B0 ≥ 7 T) MRI provides substantial gains in signal‐to‐noise ratio, spatial resolution and contrast. Routine clinical deployment has been limited by challenges of transmit field (B1+) inhomogeneity and specific absorption rate (SAR). Parallel transmission (pTx) can mitigate these challenges but it requires per‐channel complex B1+ maps to design effective pTx pulses. We review established and emerging approaches to obtain these maps. We begin by summarising the underlying physical principles and theory. Then we describe methods for magnitude B1+ mapping such as actual flip‐angle imaging (AFI), saturation‐prepared B1+ mapping (e.g., satTFL) and dual refocusing echo acquisition mode (DREAM) that are the basis of widely‐applied per‐channel complex B1+ mapping methods, as well as methods of pedagogical and/or historical relevance. Next, we describe how relative B1+ mapping with low‐flip angle gradient‐recalled echo (GRE) scans can determine the relative phases (and relative magnitudes) of B1+ for each channel. We recap the important interferometric approach that is now widely used. We explain how magnitude and phase maps are combined into complex per‐channel B1+ maps. We discuss remaining arbitrary factors such as the position‐dependent transmit reference phase. We discuss recent practical implementations such as Sandwich TFL, 3DREAM, compressed‐sensing SA2RAGE and respiratory‐resolved B1+ mapping. We explore the workflow improvements that could accrue if per‐channel B1+ maps do not need to be acquired for every subject. This includes deep‐learning–based approaches to synthesize B1+ maps from the normal localiser scans, the universal pulses (UPs) approach to precalibrate pulses and variants such as standardised universal pulses (SUPs), Fast‐Online Customised (FOCUS) and machine‐learning online customisation. We hope to encourage greater openness and harmonisation of these critical calibration steps for parallel transmit pulse design. This will become increasingly important as 7‐T pTx MRI is adopted for multisite cross‐vendor clinical research studies and to deliver the full scientific potential of new extremely high field human MRIs.
SN  - 0952-3480
SN  - 1099-1492
ER  -