Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 39 min ago
Peer-reviewedCC BY 4.0International Journal of Molecular Sciences

In Vitro Evaluation of the Biological Response to Clinically Relevant Alumina-Toughened Zirconia (ATZ) Surfaces

  1. 1Department of Health Sciences, Center for Translational Research on Autoimmune and Allergic Diseases CAAD, Università del Piemonte Orientale UPO, 28100 Novara, Italy
  2. 2Department of Applied Science and Technology, Politecnico di Torino, 10129 Turin, Italy
  3. 3CeramTec GmbH, Medical Products Division, 73207 Plochingen, Germany

Abstract

Despite favorable clinical outcomes, alumina-toughened zirconia (ATZ) dental implant bioactivity remains poorly investigated. Therefore, this study aimed to evaluate the in vitro bioactivity of clinically relevant ATZ surfaces in comparison with yttria-stabilized tetragonal zirconia (TZP) and titanium grade 4 (TiGr4). Disc-shaped ATZ and TZP samples were either sandblasted with or without additional acid etching and additionally irradiated with UV. Sandblasted and acid-etched TiGr4 surfaces were used as reference. Specimens were tested for cytocompatibility with human osteoblasts, early and late osteogenesis using human mesenchymal stromal cells (hMSCs), and bacteriostatic activity against the periodontal pathogens Porphyromonas gingivalis and Aggregatibacter actinomycetemcomitans. Moreover, the selective activity was evaluated by a bacteria-cells co-culture using hMSCs co-cultured with A. actinomycetemcomitans. Results demonstrated that all materials were cytocompatible (>70% viability) and successfully supported osteoblast adhesion. Osteogenic studies revealed comparable early gene expression, while late osteo-gene expression suggested different signatures: an up-regulation of RUNX2 and ALP was observed for TZP surfaces, while COL1 and OCN were up-regulated in ATZ surfaces. Finally, compared with TiGr4, ATZ specimens showed lower levels of contamination by both P. gingivalis and A. actinomycetemcomitans, although this difference was not statistically significant (p > 0.05). Furthermore, ATZ surfaces promoted hMSCs surface colonization, counteracting bacteria in co-culture studies, thus promoting implant sealing over infection.

Related

  1. Early and mature Achromobacter xylosoxidans biofilm in cystic fibrosis and non-cystic fibrosis isolates: dynamics and response to clinically relevant antibiotics
    Vincent Jean-Pierre, Pauline Sorlin, Catherine Dunyach-Remy +5
    BiofilmPeer-reviewedCC BY 4.0Full textMolecular biology & gene regulationHAL
  2. Taxifolin Attenuates Bacterial Pathogenicity and Thereby Enhances Antibacterial Efficacy in Clinically Relevant Bacteria
    Ji-Hyun Yoon, Yeo-Jin Kim, Ki-Young Kim
    International Journal of Molecular SciencesPeer-reviewedCC BY 4.0Full textMolecular biology & gene regulationCrossrefPMC
  3. Grey mouse lemurs, Microcebus murinus, are a relevant model to study gut microbiome flexibility in response to diet changes
    Maxime Naour, Isabelle Grit, Patricia Parnet +2
    HALPreprintPublisher termsFull textMolecular biology & gene regulationHAL
  4. Spectroscopic evaluation of the interaction of myoglobin with biomedically relevant compounds
    Alexandra Mânzat, Nicoleta Andrian, Cezara Zăgrean-Tuza +2
    Journal of Biological Inorganic ChemistryPeer-reviewedCC BY 4.0Full textGeneral biochemistryPMC
  5. Recent advances in scaffold-based KRASG12C inhibitors: SAR and biological evaluation insights
    Tomojit Bhattacharjee, Ankush Kumar, Thakur Gurjeet Singh +1
    RSC Medicinal ChemistryPeer-reviewedPublisher termsFull textMolecular biology & gene regulationPMC
BibTeX
@article{scalia2026vitro,
  title = {{In Vitro Evaluation of the Biological Response to Clinically Relevant Alumina-Toughened Zirconia (ATZ) Surfaces}},
  author = {Alessandro Calogero Scalia and Sara Ferraris and Ziba Najmi and Ina Lackner and Yvonne Mödinger and Mateusz Maria Juszczyk and Alessandro Alan Porporati and Lia Rimondini and Silvia Spriano and Andrea Cochis},
  journal = {International Journal of Molecular Sciences},
  year = {2026},
  month = nov,
  doi = {10.3390/ijms272310591},
  url = {https://www.mdpi.com/1422-0067/27/23/10591},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - In Vitro Evaluation of the Biological Response to Clinically Relevant Alumina-Toughened Zirconia (ATZ) Surfaces
AU  - Alessandro Calogero Scalia
AU  - Sara Ferraris
AU  - Ziba Najmi
AU  - Ina Lackner
AU  - Yvonne Mödinger
AU  - Mateusz Maria Juszczyk
AU  - Alessandro Alan Porporati
AU  - Lia Rimondini
AU  - Silvia Spriano
AU  - Andrea Cochis
PY  - 2026
DA  - 2026/11/24
JO  - International Journal of Molecular Sciences
DO  - 10.3390/ijms272310591
UR  - https://www.mdpi.com/1422-0067/27/23/10591
AB  - Despite favorable clinical outcomes, alumina-toughened zirconia (ATZ) dental implant bioactivity remains poorly investigated. Therefore, this study aimed to evaluate the in vitro bioactivity of clinically relevant ATZ surfaces in comparison with yttria-stabilized tetragonal zirconia (TZP) and titanium grade 4 (TiGr4). Disc-shaped ATZ and TZP samples were either sandblasted with or without additional acid etching and additionally irradiated with UV. Sandblasted and acid-etched TiGr4 surfaces were used as reference. Specimens were tested for cytocompatibility with human osteoblasts, early and late osteogenesis using human mesenchymal stromal cells (hMSCs), and bacteriostatic activity against the periodontal pathogens Porphyromonas gingivalis and Aggregatibacter actinomycetemcomitans. Moreover, the selective activity was evaluated by a bacteria-cells co-culture using hMSCs co-cultured with A. actinomycetemcomitans. Results demonstrated that all materials were cytocompatible (>70% viability) and successfully supported osteoblast adhesion. Osteogenic studies revealed comparable early gene expression, while late osteo-gene expression suggested different signatures: an up-regulation of RUNX2 and ALP was observed for TZP surfaces, while COL1 and OCN were up-regulated in ATZ surfaces. Finally, compared with TiGr4, ATZ specimens showed lower levels of contamination by both P. gingivalis and A. actinomycetemcomitans, although this difference was not statistically significant (p > 0.05). Furthermore, ATZ surfaces promoted hMSCs surface colonization, counteracting bacteria in co-culture studies, thus promoting implant sealing over infection.
SN  - 1422-0067
ER  -