Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated just now
PreprintCC BYmedRxiv

Natural interaction based visual field prediction in virtual reality - a pilot study

  1. 1Institute for Ophthalmic Research, University of Tübingen, 72076 Tübingen, Germany

Abstract

Objective: The aim was to develop and evaluate the Passive Visual Field Measurement (PVFM), a novel visual field (VF) measurement tool that predicts the VF from a user's natural, intuitive interactions in a virtual reality (VR) environment. Due to the flexible nature of its input, the tool could be integrated with various interactive VR tasks and even run passively in the background of tasks users are already motivated to carry out, such as preventive exercises or rehabilitation training. Methods: The PVFM was developed and compared to a conventional VF measurement method, kinetic perimetry using the Octopus 900 perimeter, in a pilot study with n=4 retinitis pigmentosa patients. Both measurements were carried out for each eye, for a total of eight sets. The measured VFs were compared using radial-weighted Intersection over Union (IoU), showing the degree to which PVFM results align with conventional VF testing. Results: For patients with largely concentric visual fields (n=6 eyes), agreement between PVFM and kinetic perimetry was high, with radial-weighted IoU of 75.4\% to 91.0\% and mean absolute angular distances between VF boundaries of 0.31{degrees} to 2.68{degrees}. In contrast, one patient with pronounced peripheral visual field areas (n=2 eyes) showed substantially lower agreement, with IoU of 29.6\% to 35.7\% and distances of 17.5{degrees} to 22.3{degrees}, as kinetic perimetry detected a larger peripheral visual area than PVFM. PVFM takes significantly longer than kinetic perimetry, however patient feedback indicates that PVFM is more enjoyable and engaging. Conclusion: The preliminary evidence of this pilot study suggests the feasibility of PVFM as an intuitive and engaging method for detecting VF boundaries in patients with concentric peripheral visual field loss, with agreement with kinetic perimetry within the range of test-retest variability reported for conventional kinetic perimetry. However, PVFM showed drastically lower agreement in peripheral, non-concentric visual field areas, a current limitation requiring further investigation and refinement.

Related

  1. Time at the curb, not the rate of head scanning, distinguishes street crossing in virtual reality with severe-to-profound visual impairment
    B. Erkat-Cohen, D. Venugopal, R. Sadeghi +5
    medRxivPreprintCC BYFull textGeneral medicinemedRxiv
  2. OP–008 Effect of virtual reality and distraction cards during inhalation therapy
    Tuğba Karakuş Türker, Tuğba Karakaya
    BMJ Paediatrics OpenPeer-reviewedCC BYObstetrics, gynaecology & paediatricsDOAJ
  3. Virtual Reality Simulation in Colonoscopy Training: A Systematic Review and Meta-analysis of Studies Published from 2019 to 2024
    Mina Bisada
    Journal of ColoproctologyPeer-reviewedCC BYFull textSurgery & anaesthesiaDOAJ
  4. The overall effects of virtual reality interventions on ICU patients : A systematic review and meta-analysis
    Xihui Sun, Vimala Ramoo, Jiangping Ma +1
    MedicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. A Valid and Reliable Virtual Reality Tool for Assessment of Arm Nonuse Post-Stroke
    R. Gangwani, S. Zodrow, A. DeAngelis +3
    medRxivPreprintAll rights reservedFull textGeneral medicinemedRxiv
BibTeX
@misc{frerichs2026natural,
  title = {{Natural interaction based visual field prediction in virtual reality - a pilot study}},
  author = {S. Frerichs and M. Kempf and B. R. Severitt and S. Wahl and A. Neugebauer},
  howpublished = {medRxiv},
  year = {2026},
  month = oct,
  doi = {10.64898/2026.10.27.26366299},
  url = {https://www.medrxiv.org/content/10.64898/2026.10.27.26366299v1},
  note = {CC BY},
}
RIS
TY  - UNPB
TI  - Natural interaction based visual field prediction in virtual reality - a pilot study
AU  - S. Frerichs
AU  - M. Kempf
AU  - B. R. Severitt
AU  - S. Wahl
AU  - A. Neugebauer
PY  - 2026
DA  - 2026/10/27
PB  - medRxiv
DO  - 10.64898/2026.10.27.26366299
UR  - https://www.medrxiv.org/content/10.64898/2026.10.27.26366299v1
AB  - Objective: The aim was to develop and evaluate the Passive Visual Field Measurement (PVFM), a novel visual field (VF) measurement tool that predicts the VF from a user's natural, intuitive interactions in a virtual reality (VR) environment. Due to the flexible nature of its input, the tool could be integrated with various interactive VR tasks and even run passively in the background of tasks users are already motivated to carry out, such as preventive exercises or rehabilitation training. Methods: The PVFM was developed and compared to a conventional VF measurement method, kinetic perimetry using the Octopus 900 perimeter, in a pilot study with n=4 retinitis pigmentosa patients. Both measurements were carried out for each eye, for a total of eight sets. The measured VFs were compared using radial-weighted Intersection over Union (IoU), showing the degree to which PVFM results align with conventional VF testing. Results: For patients with largely concentric visual fields (n=6 eyes), agreement between PVFM and kinetic perimetry was high, with radial-weighted IoU of 75.4\% to 91.0\% and mean absolute angular distances between VF boundaries of 0.31{degrees} to 2.68{degrees}. In contrast, one patient with pronounced peripheral visual field areas (n=2 eyes) showed substantially lower agreement, with IoU of 29.6\% to 35.7\% and distances of 17.5{degrees} to 22.3{degrees}, as kinetic perimetry detected a larger peripheral visual area than PVFM. PVFM takes significantly longer than kinetic perimetry, however patient feedback indicates that PVFM is more enjoyable and engaging. Conclusion: The preliminary evidence of this pilot study suggests the feasibility of PVFM as an intuitive and engaging method for detecting VF boundaries in patients with concentric peripheral visual field loss, with agreement with kinetic perimetry within the range of test-retest variability reported for conventional kinetic perimetry. However, PVFM showed drastically lower agreement in peripheral, non-concentric visual field areas, a current limitation requiring further investigation and refinement.
ER  -