P134. Noncontact breathing and acoustic assessment for pediatric sleep-disordered breathing diagnosis
Abstract
Objectives: To evaluate the feasibility of a novel unobtrusive under-mattress and bedside sensor system for continuous, multi-night home tracking of sleep, respiratory and snoring disturbances in children.
Methods: In this ongoing trial, children aged 2–11 years with suspected OSA undergo ~2-weeks of in-home non-contact mattress-sensor and ≥3-nights of pulse oximetry recordings. Device recorded cardiorespiratory and motion signals undergo off-line processing, via an adult-trained multi-task deep learning model, to extract sleep and respiratory metrics. The device also performs real-time extraction of acoustic features in 20 msec intervals to enable off-line automated evaluation of >600 ambient/clinical noise types (e.g., snoring, coughing, gasping). Standard deviation in derived metrics to date was used to evaluate night-to-night variability (N2NV). Data are reported as mean [95% CI].
Results: In 11 children studied to date, 98 nights of device data (2–15 nights/participant, 973 hours total, 9.9 hours/night) and 35 nights of oximetry (282 hours; 8.1 hours/night) were successfully recorded. Device capture succeeded in 8/11 children with technical loss in 3 due to battery failure (2 children, 20% nights lost) or microSD capacity full (1 child, 80% nights lost). REM sleep showed lower N2NV than other stages (Wake: 9.1 [5.9, 12.2]%; NREM: 8.8% [5.8, 11.8]%; REM: 2.2 [1.7, 2.8]%). AHI N2NV was 1.1 [0.8, 1.4] events/hr, driven by hypopnea (0.9) and central apnoea (0.4) variation. Arousal index N2NV was 1.4 [1.2, 1.7] events/hr.
Conclusions: This study demonstrates the technical feasibility of high-fidelity, multi-night, non-contact home sleep monitoring. Further paediatric-specific device algorithm fine-tuning should enhance diagnostic capabilities.
Related
- Prefrontal Activation and Cognitive Heterogeneity in Pediatric Sleep-Disordered Breathing
- Electrocardiographic Changes Following Pediatric Adenotonsillectomy for Obstructive Sleep-Disordered Breathing: A Pilot Prospective Study
- Deep learning for multimodal physiological signal based assessment of sleep disordered breathing
- Muscular Response in Sleep-Disordered Breathing Patients: New Methods of Assessment and Measurement.
- A Retrospective Review of Oromyofunctional Therapy in the Treatment of Pediatric Sleep-Disordered Breathing: A Local Single-Center Study
BibTeX
@article{nguyen2026p134,
title = {{P134. Noncontact breathing and acoustic assessment for pediatric sleep-disordered breathing diagnosis}},
author = {D Nguyen and A Pinczel and C O’Reilly and A Teare and A Leviton and T Nguyen and M O’Grady and D Eckert and B Lechat and J Grillo and L Wigston and I Dong and S Shivji and H Storey and V Padhye and P Catcheside and A Carney},
journal = {Sleep advances : a journal of the Sleep Research Society},
year = {2026},
month = nov,
doi = {10.1093/sleepadvances/zpag103.187},
url = {https://europepmc.org/article/PMC/PMC13783313},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - P134. Noncontact breathing and acoustic assessment for pediatric sleep-disordered breathing diagnosis
AU - D Nguyen
AU - A Pinczel
AU - C O’Reilly
AU - A Teare
AU - A Leviton
AU - T Nguyen
AU - M O’Grady
AU - D Eckert
AU - B Lechat
AU - J Grillo
AU - L Wigston
AU - I Dong
AU - S Shivji
AU - H Storey
AU - V Padhye
AU - P Catcheside
AU - A Carney
PY - 2026
DA - 2026/11/01
JO - Sleep advances : a journal of the Sleep Research Society
DO - 10.1093/sleepadvances/zpag103.187
UR - https://europepmc.org/article/PMC/PMC13783313
AB - Objectives: To evaluate the feasibility of a novel unobtrusive under-mattress and bedside sensor system for continuous, multi-night home tracking of sleep, respiratory and snoring disturbances in children. Methods: In this ongoing trial, children aged 2–11 years with suspected OSA undergo ~2-weeks of in-home non-contact mattress-sensor and ≥3-nights of pulse oximetry recordings. Device recorded cardiorespiratory and motion signals undergo off-line processing, via an adult-trained multi-task deep learning model, to extract sleep and respiratory metrics. The device also performs real-time extraction of acoustic features in 20 msec intervals to enable off-line automated evaluation of >600 ambient/clinical noise types (e.g., snoring, coughing, gasping). Standard deviation in derived metrics to date was used to evaluate night-to-night variability (N2NV). Data are reported as mean [95% CI]. Results: In 11 children studied to date, 98 nights of device data (2–15 nights/participant, 973 hours total, 9.9 hours/night) and 35 nights of oximetry (282 hours; 8.1 hours/night) were successfully recorded. Device capture succeeded in 8/11 children with technical loss in 3 due to battery failure (2 children, 20% nights lost) or microSD capacity full (1 child, 80% nights lost). REM sleep showed lower N2NV than other stages (Wake: 9.1 [5.9, 12.2]%; NREM: 8.8% [5.8, 11.8]%; REM: 2.2 [1.7, 2.8]%). AHI N2NV was 1.1 [0.8, 1.4] events/hr, driven by hypopnea (0.9) and central apnoea (0.4) variation. Arousal index N2NV was 1.4 [1.2, 1.7] events/hr. Conclusions: This study demonstrates the technical feasibility of high-fidelity, multi-night, non-contact home sleep monitoring. Further paediatric-specific device algorithm fine-tuning should enhance diagnostic capabilities.
SN - 2632-5012
ER -