Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 34 min ago
Peer-reviewedCC BY-NC-ND 4.0BMC Musculoskeletal Disorders

A simple independent high-strength suture augmentation significantly improves tendon biomechanical properties in anterior cruciate ligament reconstruction

14 affiliations
  1. 1Nam Sai Gon International Hospital, Ho Chi Minh City, Vietnam
  2. 2Sports Medic Clinic, Ho Chi Minh City, Vietnam
  3. 3Department of Orthopedic Surgery and Traumatology, University, Kantonsspital Baselland, Bruderholz, CH-4101 Switzerland
  4. 4Department of Clinical Research, Research Group Michael T. Hirschmann, Regenerative Medicine & Biomechanics, University of Basel, Basel, CH-4001 Switzerland
  5. 5Deanery of Biomedical Sciences at Edinburgh Medical School, University of Edinburgh, Edinburgh, UK
  6. 6Center for Orthopedics and Sports Medicine, Vinmec Healthcare System, Vinmec Ocean Park 2 Hospital, Hung Yen, Vietnam
  7. 7University College London, London, UK
  8. 8School of Medicine and Pharmacy, Duy Tan University, Da Nang, Vietnam
  9. 9Institute of Research and Development, Duy Tan University, Da Nang, Vietnam
  10. 10Department of Obstetrics and Gynecology, Hessenklinik Stadtkrankenhaus Korbach, Enser St. 19, 34497 Korbach, Germany
  11. 11Department of General Practice and Health Service Research, University Hospital Heidelberg, Im Neuenheimer Feld 130.3, 69120 Heidelberg, Germany
  12. 12Department of Hepato-Biliary-Pancreatic Surgery, Thong Nhat Hospital, Ho Chi Minh City, Vietnam
  13. 13Department of Hepato-Biliary-Pancreatic Sciences, Faculty of Medicine, University of Health and Sciences, Vietnam National University, Ho Chi Minh City, Vietnam
  14. 14School of Tropical Medicine and Global Health, Nagasaki University, Nagasaki, 852-8523 Japan

Abstract

Purpose: The all-inside anterior cruciate ligament reconstruction (ACLR) technique heavily depends on continuous graft stability, making graft preparation critical. Graft augmentation techniques have been proposed to enhance stability in ACLR. This biomechanical study investigated whether an independent high-strength suture augmentation, applied parallel to the tendon graft, improves construct properties.

Methods: Thirty-eight specimens were allocated to three groups: Suture (n = 10; No. 2 non-absorbable braided polyethylene), Graft (n = 13; bovine tendon), and Graft+Suture (n = 15; combined construct). All specimens underwent uniaxial tensile testing, including a preconditioning phase from 0 to 350 N followed by a load-to-failure test at 50 mm/min to determine elongation (mm), ultimate failure load (UFL, in N), and construct stiffness (N/mm). Statistical analysis was performed using one-way ANOVA with Bonferroni post-hoc analysis.

Results: The Graft+Suture group exhibited significantly lower elongation (2.72 ± 0.51 mm) compared with both the Graft group (4.44 ± 1.59 mm; MD -1.71 mm, 95% CI -2.86 to -0.56; p = 0.002) and the Suture group (7.77 ± 1.37 mm; MD -5.05 mm, 95% CI -6.29 to -3.81; p < 0.001). UFL was higher in the Graft+Suture group (1327.83 ± 388.13 N) than in the Graft group (925.52 ± 337.06 N; MD 664.93 N, 95% CI 335.82 to 994.04; p < 0.001). Similarly, stiffness was greater in the Graft+Suture group (229.17 ± 25.105 N/mm) compared with the Graft group (163.880 ± 31.3 N/mm; p < 0.001).

Conclusion: In this in vitro bovine model, independent high-strength suture augmentation significantly improved tendon graft biomechanical properties, producing higher UFL and stiffness, while reducing elongation. These findings suggest a potential strategy for graft reinforcement, though a more cautious interpretation is warranted pending in vivo and clinical validation.

Level of evidence: Not applicable.

Supplementary information: The online version contains supplementary material available at https://doi.org/10.1186/s12891-026-10537-1.

Related

  1. The Current State of Anterior Cruciate Ligament Reconstruction: Graft Selection, Lateral Augmentation, Rehabilitation, and Return-to-Play
    Jeffrey George, Andrew J. Moyal, Isha K. Shah +4
    Current reviews in musculoskeletal medicinePeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  2. Corvis ST Assessment of Corneal Biomechanical Properties in Patients with Type 2 Diabetes Mellitus
    Aida Kasumović Bećirević, Armin Kasumović, Ines Matoc Kasumović +5
    Medicina (Kaunas, Lithuania)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. All‐Inside Posterior Cruciate Ligament Reconstruction Using Achilles Allograft and Suture Tape Augmentation
    Badrul Akmal Hisham Md Yusoff, Alif Zhafri, Muhammad Karbela Reza Ramlan +4
    Arthroscopy techniquesPeer-reviewedCC BY-NCFull textSurgery & anaesthesiaEurope PMCEurope PMCPMC
  4. Facet joint fusion in lumbar surgery: a biomechanical review of posterior column preservation and reconstruction.
    Tong Xu, Xingyu Zhao, Lei Zhang +8
    Frontiers in surgeryPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  5. Biomechanical Analysis of Autologous Graft Configurations for Knee Ligament Reconstruction: A Cadaveric Study
    M.B.G. Lopes, C.P. Helito, S.M.D.G. Canuto +3
    Orthopaedic Journal of Sports MedicinePeer-reviewedCC BYFull textSurgery & anaesthesiaDOAJ
BibTeX
@article{dung2026simple,
  title = {{A simple independent high-strength suture augmentation significantly improves tendon biomechanical properties in anterior cruciate ligament reconstruction}},
  author = {Truong Cong Dung and Randa Elsheikh and To Dong Kha and Nguyen Thanh An and Abdelrahman M Makram and Pham Trung Chanh and Nguyen Hai Nam and Nguyen Tien Huy},
  journal = {BMC Musculoskeletal Disorders},
  year = {2026},
  month = nov,
  doi = {10.1186/s12891-026-10537-1},
  url = {https://doi.org/10.1186/s12891-026-10537-1},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - A simple independent high-strength suture augmentation significantly improves tendon biomechanical properties in anterior cruciate ligament reconstruction
AU  - Truong Cong Dung
AU  - Randa Elsheikh
AU  - To Dong Kha
AU  - Nguyen Thanh An
AU  - Abdelrahman M Makram
AU  - Pham Trung Chanh
AU  - Nguyen Hai Nam
AU  - Nguyen Tien Huy
PY  - 2026
DA  - 2026/11/03
JO  - BMC Musculoskeletal Disorders
DO  - 10.1186/s12891-026-10537-1
UR  - https://doi.org/10.1186/s12891-026-10537-1
AB  - Purpose: The all-inside anterior cruciate ligament reconstruction (ACLR) technique heavily depends on continuous graft stability, making graft preparation critical. Graft augmentation techniques have been proposed to enhance stability in ACLR. This biomechanical study investigated whether an independent high-strength suture augmentation, applied parallel to the tendon graft, improves construct properties.  Methods: Thirty-eight specimens were allocated to three groups: Suture (n = 10; No. 2 non-absorbable braided polyethylene), Graft (n = 13; bovine tendon), and Graft+Suture (n = 15; combined construct). All specimens underwent uniaxial tensile testing, including a preconditioning phase from 0 to 350 N followed by a load-to-failure test at 50 mm/min to determine elongation (mm), ultimate failure load (UFL, in N), and construct stiffness (N/mm). Statistical analysis was performed using one-way ANOVA with Bonferroni post-hoc analysis.  Results: The Graft+Suture group exhibited significantly lower elongation (2.72 ± 0.51 mm) compared with both the Graft group (4.44 ± 1.59 mm; MD -1.71 mm, 95% CI -2.86 to -0.56; p = 0.002) and the Suture group (7.77 ± 1.37 mm; MD -5.05 mm, 95% CI -6.29 to -3.81; p < 0.001). UFL was higher in the Graft+Suture group (1327.83 ± 388.13 N) than in the Graft group (925.52 ± 337.06 N; MD 664.93 N, 95% CI 335.82 to 994.04; p < 0.001). Similarly, stiffness was greater in the Graft+Suture group (229.17 ± 25.105 N/mm) compared with the Graft group (163.880 ± 31.3 N/mm; p < 0.001).  Conclusion: In this in vitro bovine model, independent high-strength suture augmentation significantly improved tendon graft biomechanical properties, producing higher UFL and stiffness, while reducing elongation. These findings suggest a potential strategy for graft reinforcement, though a more cautious interpretation is warranted pending in vivo and clinical validation.  Level of evidence: Not applicable.  Supplementary information: The online version contains supplementary material available at https://doi.org/10.1186/s12891-026-10537-1.
SN  - 1471-2474
ER  -