Safety and effectiveness of gaseous ozone for residue-free textile decontamination in hospitals

Abstract

Background: Healthcare-associated infections (HAIs) significantly impact patient safety and costs. Textiles for medical uniforms are known transmission vehicles, yet conventional laundering often fails to disinfect areas like seams or requires damaging chemicals and high temperatures. This study evaluates gaseous ozone as a sustainable, residue-free alternative for textile decontamination.

Methods: Antimicrobial efficacy was tested using a 900 rotary automatic dispenser (Zucchetti Centro Sistemi, Italy). This device features a fully hermetic design for an airtight environment and a catalyst system to accelerate ozone conversion back into oxygen, ensuring safe post-treatment conditions. The system includes an advanced sanitization system with two exposure programs (25 and 45 minutes) at a concentration of 4.5 ppm. Tests were conducted on 100% cotton, 100% polyester, and 40/60 blend fabrics artificially contaminated with Staphylococcus aureus, Escherichia coli, and Candida albicans (10-10⁵ CFU/mL). Ozone penetration was assessed using five stacked fabric layers. Worker safety was monitored via IQ-610 probes to calculate 8-hour Time-Weighted Average (TWA) values. Differences between ozone-treated and control samples were analyzed using Student’s t-test (p < 0.05).

Results: A 25-minute cycle significantly reduced the microbial load on all fabrics. The 45-minute cycle achieved almost complete pathogen elimination (>4-log reduction). Ozone effectively penetrated multiple layers, achieving total bacterial eradication and a 1.4-log reduction in C. albicans. Ventilation-only controls confirmed that reduction was solely due to ozone. TWA ozone concentrations remained below the 0.1 ppm OSHA limit at both 1 m and 50 cm distances.

Conclusions: Gaseous ozone via a rotary dispenser provides thorough decontamination, reaching areas resistant to conventional cleaning. This technology offers a safe, eco-friendly solution to reduce HAI transmission in healthcare settings.

Key messages: • Gaseous ozone provides high-level decontamination across multiple fabric layers, effectively eliminating key pathogens to reduce healthcare-associated infection risks through medical textiles.

• This sustainable, chemical-free method achieves near-total pathogen elimination across various textiles, offering a robust and eco-friendly alternative to improve hospital hygiene standards.

Related

  1. Effectiveness of ultraviolet–C robots in isolation room disinfection: Impact of dose, distance, and direct exposure on environmental surface decontamination
    Ying-Chun Chen, Wei-Ling Liao, Su-Chiu Wang +1
    PLOS OnePeer-reviewedCC BY 4.0MicrobiologyEpidemiology & public healthPLOS
  2. Decontamination, Dilution, and Diachronic Blameworthiness
    Bobby Johnson, Zhexi Zhang, Andrew James Latham +1
    Australasian Journal of PhilosophyPeer-reviewedCC BY-NC-NDFull text7 citedNeuroscienceOpenAlex
  3. Accurate and scalable decontamination of imaging-based spatial transcriptomics via optimal transport
    Y. Chen, Y. Liu, Z. Chao +9
    bioRxivPreprintCC BY-NC-NDFull textBioinformatics & computational biologybioRxiv
  4. TRUEDA overturns replicated, decontaminated low-biomass disease-microbe associations and clinical decisions, recovers true pathogens and outperforms every decontamination method
    H. Jiang, F. Gao, Y. Wu +5
    bioRxivPreprintCC BYFull textMicrobiologybioRxiv
  5. Substrate-driven shifts in microbial communities reshape metabolite profiles during soybean residue fermentation
    Gaorui Bian, Yamei Gu, Yaoxing Tang +5
    Frontiers in microbiologyPeer-reviewedCC BYFull textMicrobiologyEurope PMC
BibTeX
@article{tomeo2026safety,
  title = {{Safety and effectiveness of gaseous ozone for residue-free textile decontamination in hospitals}},
  author = {M Tomeo and G Moccia and F Della Rocca and A Mea and E Santoro and O Motta and G Boccia and M Capunzo and G Franci and F De Caro},
  journal = {The European Journal of Public Health},
  year = {2026},
  month = oct,
  doi = {10.1093/eurpub/ckag169.1619},
  url = {https://doi.org/10.1093/eurpub/ckag169.1619},
  note = {CC BY-NC 4.0},
}
RIS
TY  - JOUR
TI  - Safety and effectiveness of gaseous ozone for residue-free textile decontamination in hospitals
AU  - M Tomeo
AU  - G Moccia
AU  - F Della Rocca
AU  - A Mea
AU  - E Santoro
AU  - O Motta
AU  - G Boccia
AU  - M Capunzo
AU  - G Franci
AU  - F De Caro
PY  - 2026
DA  - 2026/10/01
JO  - The European Journal of Public Health
DO  - 10.1093/eurpub/ckag169.1619
UR  - https://doi.org/10.1093/eurpub/ckag169.1619
AB  - Background: Healthcare-associated infections (HAIs) significantly impact patient safety and costs. Textiles for medical uniforms are known transmission vehicles, yet conventional laundering often fails to disinfect areas like seams or requires damaging chemicals and high temperatures. This study evaluates gaseous ozone as a sustainable, residue-free alternative for textile decontamination.  Methods: Antimicrobial efficacy was tested using a 900 rotary automatic dispenser (Zucchetti Centro Sistemi, Italy). This device features a fully hermetic design for an airtight environment and a catalyst system to accelerate ozone conversion back into oxygen, ensuring safe post-treatment conditions. The system includes an advanced sanitization system with two exposure programs (25 and 45 minutes) at a concentration of 4.5 ppm. Tests were conducted on 100% cotton, 100% polyester, and 40/60 blend fabrics artificially contaminated with Staphylococcus aureus, Escherichia coli, and Candida albicans (10-10⁵ CFU/mL). Ozone penetration was assessed using five stacked fabric layers. Worker safety was monitored via IQ-610 probes to calculate 8-hour Time-Weighted Average (TWA) values. Differences between ozone-treated and control samples were analyzed using Student’s t-test (p < 0.05).  Results: A 25-minute cycle significantly reduced the microbial load on all fabrics. The 45-minute cycle achieved almost complete pathogen elimination (>4-log reduction). Ozone effectively penetrated multiple layers, achieving total bacterial eradication and a 1.4-log reduction in C. albicans. Ventilation-only controls confirmed that reduction was solely due to ozone. TWA ozone concentrations remained below the 0.1 ppm OSHA limit at both 1 m and 50 cm distances.  Conclusions: Gaseous ozone via a rotary dispenser provides thorough decontamination, reaching areas resistant to conventional cleaning. This technology offers a safe, eco-friendly solution to reduce HAI transmission in healthcare settings.  Key messages: • Gaseous ozone provides high-level decontamination across multiple fabric layers, effectively eliminating key pathogens to reduce healthcare-associated infection risks through medical textiles.  • This sustainable, chemical-free method achieves near-total pathogen elimination across various textiles, offering a robust and eco-friendly alternative to improve hospital hygiene standards.
SN  - 1101-1262
SN  - 1464-360X
ER  -