The in-vitro investigation of the effect of finishing and polishing methods on the surface roughness of composites

  1. 1Department of Restorative Dentistry, Faculty of Dentistry, Ankara University, Emniyet, Mevlana Blv. No:19/1, Yenimahalle, Ankara, 06560 Türkiye
  2. 2Department of Restorative Dentistry, Faculty of Dentistry, Kocaeli Health and Technology University, Kocaeli, Türkiye

Abstract

Background: Surface roughness of resin composite restorations is influenced by both the restorative material and the finishing/polishing protocol. Because rougher surfaces may favor plaque retention, staining, and wear, material-dependent responses to polishing systems remain clinically relevant. This in vitro study evaluated the effect of five finishing and polishing systems on the surface roughness of two anterior resin composites with different filler characteristics.

Methods: One hundred and twenty disk-shaped specimens (6 mm diameter × 2 mm thickness) were prepared from two resin composites, G-aenial Anterior and Estelite Asteria. Each composite was randomly allocated to six groups (n = 10). Five groups were finished and polished with the assigned system: Sof-Lex and OptiDisc (multi-step aluminum oxide disc systems), Clearfil Twist Dia (two-step diamond-impregnated spiral system), OneGloss (one-step rubber system), and Sof-Lex Spiral (two-step rubber spiral system). As a control, composite specimens were light-cured against a Mylar strip, resulting in a smooth, unpolished reference surface. Surface roughness was measured with a contact profilometer and reported as Ra (µm). One representative specimen from each group was examined qualitatively by scanning electron microscopy (SEM). Data were tested for normality using the Shapiro-Wilk test and analyzed using the Kruskal-Wallis test with Bonferroni-adjusted pairwise post hoc comparisons and the Mann-Whitney U test (α = 0.05).

Results: In both composites, the Mylar strip control produced the lowest Ra values. Among the polishing systems, Sof-Lex and OptiDisc produced lower roughness values than OneGloss and Sof-Lex Spiral. Estelite Asteria generally showed lower roughness than G-aenial Anterior; this difference was significant in the control, OptiDisc, Twist Dia, and overall material comparisons. SEM observations qualitatively illustrated smoother surfaces in the control and disc-polished groups.

Conclusions: Within the limitations of this in vitro study, both composite type and finishing/polishing system affected surface roughness. Multi-step aluminum oxide disc systems were associated with lower Ra values than the tested one-step rubber system and Sof-Lex Spiral. The findings should be interpreted as initial surface roughness data and should not be extrapolated directly to long-term clinical performance without aging, wear, gloss, hardness, and biofilm-related outcomes.

Related

  1. Psychological Assets and Cardiovascular Health in Adulthood: A Mixed Methods Investigation
    Julia K. Boehm, Farah Qureshi, Laura D. Kubzansky
    Journal of the American Heart AssociationPeer-reviewedLicence not statedCardiovascular medicineCrossref
  2. Adolescent Perspectives on Parental Consent Requirements for Depression Treatment: A Mixed-Methods Investigation
    Amanda Smock, Tubanji Walubita, Andy Rapoport +7
    PsyArXivPreprintCC0Full textPsychiatry & mental healthOSF
  3. Mixed methods investigation into provision of family rooms and support for parents admitted to psychiatric inpatient units and their children: Study protocol
    Abby Dunn, Chloe Elsby-Pearson, Luise Kalus +3
    PLOS OnePeer-reviewedCC BY 4.0Full textPsychiatry & mental healthPLOS
  4. Porous Boron Carbide Matrices: Effects of Surface Polishing on Initial Cytocompatibility in Human Fibroblast Culture—An In Vitro Study
    BiomedicinesPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. An investigation of lifestyle behaviors, mental well-being, and work-related outcomes among female teachers: mixed-methods evidence for occupational health promotion
    Shereen S. AlSuwaimel, Ali Saad R. Alsubaie
    Frontiers in Public HealthPeer-reviewedCC BY 4.0Full textEpidemiology & public healthCrossrefPMC
BibTeX
@article{soylu2026invitro,
  title = {{The in-vitro investigation of the effect of finishing and polishing methods on the surface roughness of composites}},
  author = {Kerem Soylu and Gurcag Gur and Gurkan Gur},
  journal = {BMC Oral Health},
  year = {2026},
  month = aug,
  doi = {10.1186/s12903-026-09619-2},
  url = {https://doi.org/10.1186/s12903-026-09619-2},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - The in-vitro investigation of the effect of finishing and polishing methods on the surface roughness of composites
AU  - Kerem Soylu
AU  - Gurcag Gur
AU  - Gurkan Gur
PY  - 2026
DA  - 2026/08/01
JO  - BMC Oral Health
DO  - 10.1186/s12903-026-09619-2
UR  - https://doi.org/10.1186/s12903-026-09619-2
AB  - Background: Surface roughness of resin composite restorations is influenced by both the restorative material and the finishing/polishing protocol. Because rougher surfaces may favor plaque retention, staining, and wear, material-dependent responses to polishing systems remain clinically relevant. This in vitro study evaluated the effect of five finishing and polishing systems on the surface roughness of two anterior resin composites with different filler characteristics.  Methods: One hundred and twenty disk-shaped specimens (6 mm diameter × 2 mm thickness) were prepared from two resin composites, G-aenial Anterior and Estelite Asteria. Each composite was randomly allocated to six groups (n = 10). Five groups were finished and polished with the assigned system: Sof-Lex and OptiDisc (multi-step aluminum oxide disc systems), Clearfil Twist Dia (two-step diamond-impregnated spiral system), OneGloss (one-step rubber system), and Sof-Lex Spiral (two-step rubber spiral system). As a control, composite specimens were light-cured against a Mylar strip, resulting in a smooth, unpolished reference surface. Surface roughness was measured with a contact profilometer and reported as Ra (µm). One representative specimen from each group was examined qualitatively by scanning electron microscopy (SEM). Data were tested for normality using the Shapiro-Wilk test and analyzed using the Kruskal-Wallis test with Bonferroni-adjusted pairwise post hoc comparisons and the Mann-Whitney U test (α = 0.05).  Results: In both composites, the Mylar strip control produced the lowest Ra values. Among the polishing systems, Sof-Lex and OptiDisc produced lower roughness values than OneGloss and Sof-Lex Spiral. Estelite Asteria generally showed lower roughness than G-aenial Anterior; this difference was significant in the control, OptiDisc, Twist Dia, and overall material comparisons. SEM observations qualitatively illustrated smoother surfaces in the control and disc-polished groups.  Conclusions: Within the limitations of this in vitro study, both composite type and finishing/polishing system affected surface roughness. Multi-step aluminum oxide disc systems were associated with lower Ra values than the tested one-step rubber system and Sof-Lex Spiral. The findings should be interpreted as initial surface roughness data and should not be extrapolated directly to long-term clinical performance without aging, wear, gloss, hardness, and biofilm-related outcomes.
SN  - 1472-6831
ER  -