An anatomically grounded human-scale dynamic model of contraction-driven lymphatic pumping

Abstract

Lymphangions, the valved muscular segments of lymphatic vessels, pump lymph against an adverse pressure gradient. Current models resolve this pumping in one vessel, a short chain or a regional network, and whole-body human models are passive. We extend the passive whole-body network of a companion static study to the active regime on the same anatomical graph, with intrinsic contraction, dynamic valves and a respiration-gated venous outlet on every vessel. Without fitting the waveform or the contraction amplitude, the network settles into a bounded pumping cycle at the lymphovenous junction, at a clinical pressure of 7.5 to 12.3 mmHg and a drainage of 35 to 50 mm^3/s. Respiration adds a swing of 1 to 2.5 mmHg at the junction and contraction about 1 mmHg inside the duct. Pressure generation is limited more by load than by drive, and no single contraction amplitude fits every vessel. Raising the subclavian venous pressure from 3 to 15 mmHg lifts the deep cervical node from 8.6 to 21.1 mmHg at the weakest drive, a transmission of 1.04 that falls to 0.78 at the strongest, so contraction buffers cervical drainage against venous pressure. The same solver gives the human cervical outlet pressure that cerebrospinal-fluid drainage models prescribe.

Related

  1. An anatomically grounded human-scale steady hydraulic model of the lymphatic network
    Chia-Feng Chang, Ayemon Baraka, Egor Sidorov +1
    arXivPreprintarXiv licenceFull textBiological & medical physicsFluid dynamicsarXiv
  2. Conceptual Design of Pumping Systems up to 1000 m3/s Based on Non-Evaporable Getters in a Gas-Dynamic Magnetic Trap
    Alexey M. Semenov, Nataliy G. Vasilieva, Sergey V. Polosatkin
    arXivPreprintCC BY 4.0Full textPlasma physicsarXiv
  3. Direct generation of a watt-level single-frequency vortex laser beam via annular pumping in a compact standing-wave cavity
    Zixuan Zhao, Minghao Guo, Xin Yan +5
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  4. Chirality-Induced Angular-Momentum Pumping by Moving Charges
    Jun-ichiro Kishine, Ron Naaman
    arXivPreprintarXiv licenceFull textCondensed matterQuantum physics & quantum informationarXiv
  5. Nonthermal Particle Acceleration by Magnetic Pumping in Pulsating Plasmas
    Giuseppe Arrò, Vladimir Zhdankin, Fabio Bacchini
    arXivPreprintarXiv licenceFull textHigh-energy astrophysicsPlasma physicsarXiv
BibTeX
@misc{chang2026anatomically,
  title = {{An anatomically grounded human-scale dynamic model of contraction-driven lymphatic pumping}},
  author = {Chia-Feng Chang and Ayemon Baraka and Egor Sidorov and Sabee Molloi},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.12760},
  eprint = {2610.12760},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.12760},
}
RIS
TY  - UNPB
TI  - An anatomically grounded human-scale dynamic model of contraction-driven lymphatic pumping
AU  - Chia-Feng Chang
AU  - Ayemon Baraka
AU  - Egor Sidorov
AU  - Sabee Molloi
PY  - 2026
DA  - 2026/10/08
PB  - arXiv
DO  - 10.48550/arxiv.2610.12760
UR  - https://arxiv.org/abs/2610.12760
AB  - Lymphangions, the valved muscular segments of lymphatic vessels, pump lymph against an adverse pressure gradient. Current models resolve this pumping in one vessel, a short chain or a regional network, and whole-body human models are passive. We extend the passive whole-body network of a companion static study to the active regime on the same anatomical graph, with intrinsic contraction, dynamic valves and a respiration-gated venous outlet on every vessel. Without fitting the waveform or the contraction amplitude, the network settles into a bounded pumping cycle at the lymphovenous junction, at a clinical pressure of 7.5 to 12.3 mmHg and a drainage of 35 to 50 mm^3/s. Respiration adds a swing of 1 to 2.5 mmHg at the junction and contraction about 1 mmHg inside the duct. Pressure generation is limited more by load than by drive, and no single contraction amplitude fits every vessel. Raising the subclavian venous pressure from 3 to 15 mmHg lifts the deep cervical node from 8.6 to 21.1 mmHg at the weakest drive, a transmission of 1.04 that falls to 0.78 at the strongest, so contraction buffers cervical drainage against venous pressure. The same solver gives the human cervical outlet pressure that cerebrospinal-fluid drainage models prescribe.
ER  -