Quantitative CT Geometry of the Patent Ductus Arteriosus in Infants with Congenital Heart Disease: Association with Aortic Arch Obstruction or Hypoplasia
6 affiliations
- 1Faculty of Medicine in English, George Emil Palade University of Medicine, Pharmacy, Science and Technology of Târgu Mureș, 540142 Târgu Mureș, Romania
- 2Radiology and Medical Imaging Laboratory, Mureș County Emergency Clinical Hospital, 540136 Târgu Mureș, Romania
- 3Emergency Institute for Cardiovascular Diseases and Transplantation of Târgu Mureș, 540139 Târgu Mureș, Romania
- 4Doctoral School of Medicine and Pharmacy, George Emil Palade University of Medicine, Pharmacy, Science and Technology of Târgu Mureș, 540142 Târgu Mureș, Romania
- 5Department of Surgery IV, George Emil Palade University of Medicine, Pharmacy, Science and Technology of Târgu Mureș, 540142 Târgu Mureș, Romania
- 6Clinic of Cardiovascular Surgery, Emergency Institute for Cardiovascular Diseases and Transplantation of Târgu Mureș, 540139 Târgu Mureș, Romania
Abstract
Background/Objectives: Quantitative patent ductus arteriosus (PDA) geometry in congenital heart disease (CHD), particularly in relation to aortic arch abnormalities, is incompletely characterized. We evaluated CT-derived PDA geometry. Methods: This retrospective exploratory single-center study included 168 infants with CHD and a PDA on cardiovascular CT. Aortic-end, pulmonary-end, and mid-duct diameters and ductal length were measured. The Ductal Length-to-Diameter Index (LDI), selected during exploratory analysis, was defined as ductal length divided by the mean end diameter. Seventy-three patients had CT-documented aortic arch obstruction or hypoplasia. Results: LDI was lower in patients with arch obstruction/hypoplasia than in those without these findings (2.04 [1.39–2.84] vs. 3.51 [2.23–4.89]; p < 0.001; rank-biserial r = −0.473) and remained associated after adjustment for age, weight, and sex (OR per +1 LDI, 0.534; 95% CI, 0.412–0.693; p < 0.001). The association remained robust with a conservative definition restricted to coarctation or interrupted aortic arch. LDI had an interobserver ICC of 0.843 (95% CI, 0.685–0.954), with wide limits of agreement (−1.98 to +2.45). Conclusions: CT-documented aortic arch obstruction or hypoplasia is associated with lower LDI. This exploratory geometric association warrants prospective external validation before clinical use.
Related
- Congenital Hypoplasia of the C1 Posterior Arch Masquerading as Multiple Sclerosis: A Case Report.
- SMAD5 as a novel susceptibility gene for congenital patent ductus arteriosus
- A Rare Cause of Pediatric Small Bowel Obstruction: Congenital Rectouterine Hernia
- Association of Adhesive Small Bowel Obstruction with Postoperative Health-related Quality of Life after Colorectal Cancer Surgery.
- Role of Telemedicine in Congenital Heart Disease Care Models in Low‐ and Middle‐Income Countries: A Scientific Statement From the American Heart Association
BibTeX
@article{pop2026quantitative,
title = {{Quantitative CT Geometry of the Patent Ductus Arteriosus in Infants with Congenital Heart Disease: Association with Aortic Arch Obstruction or Hypoplasia}},
author = {Marian Pop and Liel Bargutin and Răzvan-Andrei Licu and Marian Rotariu and Diana-Ramona Iurian and Tania Negovan and Horațiu Suciu},
journal = {Journal of Clinical Medicine},
year = {2026},
month = oct,
doi = {10.3390/jcm15208017},
url = {https://www.mdpi.com/2077-0383/15/20/8017},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Quantitative CT Geometry of the Patent Ductus Arteriosus in Infants with Congenital Heart Disease: Association with Aortic Arch Obstruction or Hypoplasia
AU - Marian Pop
AU - Liel Bargutin
AU - Răzvan-Andrei Licu
AU - Marian Rotariu
AU - Diana-Ramona Iurian
AU - Tania Negovan
AU - Horațiu Suciu
PY - 2026
DA - 2026/10/01
JO - Journal of Clinical Medicine
DO - 10.3390/jcm15208017
UR - https://www.mdpi.com/2077-0383/15/20/8017
AB - Background/Objectives: Quantitative patent ductus arteriosus (PDA) geometry in congenital heart disease (CHD), particularly in relation to aortic arch abnormalities, is incompletely characterized. We evaluated CT-derived PDA geometry. Methods: This retrospective exploratory single-center study included 168 infants with CHD and a PDA on cardiovascular CT. Aortic-end, pulmonary-end, and mid-duct diameters and ductal length were measured. The Ductal Length-to-Diameter Index (LDI), selected during exploratory analysis, was defined as ductal length divided by the mean end diameter. Seventy-three patients had CT-documented aortic arch obstruction or hypoplasia. Results: LDI was lower in patients with arch obstruction/hypoplasia than in those without these findings (2.04 [1.39–2.84] vs. 3.51 [2.23–4.89]; p < 0.001; rank-biserial r = −0.473) and remained associated after adjustment for age, weight, and sex (OR per +1 LDI, 0.534; 95% CI, 0.412–0.693; p < 0.001). The association remained robust with a conservative definition restricted to coarctation or interrupted aortic arch. LDI had an interobserver ICC of 0.843 (95% CI, 0.685–0.954), with wide limits of agreement (−1.98 to +2.45). Conclusions: CT-documented aortic arch obstruction or hypoplasia is associated with lower LDI. This exploratory geometric association warrants prospective external validation before clinical use.
SN - 2077-0383
ER -