Electro-thermal PEMFC system modeling with experimental validation on 6 kW liquid-cooled stack
Abstract
This paper presents the development and experimental validation of a coupled electrochemical–thermal numerical model of a liquid-cooled Proton Exchange Membrane Fuel Cell (PEMFC) system. The model is based on a 0D/1D formulation implemented in the Matlab/Simscape environment and aims to accurately reproduce both the electrical and thermal behavior of a PEMFC stack under variable operating conditions. The proposed approach integrates the main physical phenomena governing fuel cell operation, including electrochemical reactions, mass and energy balances, and the dynamics of the reactant supply subsystems. A particular attention is given to the modeling of non-conventional loss mechanisms, such as hydrogen crossover and internal short circuits, which significantly affect stack voltage and overall system performance. To validate the proposed model, an experimental test bench was developed using a 6 kW Ballard FCgen-LCS PEMFC stack equipped with a closed-loop liquid cooling circuit. Experimental tests were conducted under steady-state and transient load conditions to characterize the electrical response and the thermal dynamics of the system. Simulation results were compared with measured data through polarization curve analysis and dynamic thermal response evaluation. The comparison demonstrates a strong agreement between simulations and experiments, confirming the ability of the model to capture both electrical performance and stack thermal behavior. The proposed model therefore provides a reliable and computationally efficient tool for PEMFC system analysis, control development, and optimization of thermal management strategies.
Related
- Passive Gravity Compensation for Robot Manipulator Joints Using a Compression Spring–Cam Mechanism: Modeling, Design, and Experimental Validation
- Model Predictive Control for Dynamic Hydraulic Balancing in Building Radiator Heating Systems: Modeling, Design, and Experimental Validation
- Equivalent linearization modeling and experimental validation of natural frequency and vibration isolation performance in metal braided hoses
- Linear and non-linear thermal system identification based on the integral of non-integer order — Application to solve inverse heat conduction linear and non-linear problems
- Localized Hybrid Analytical-Finite-Element Thermal Modeling for Laser Powder Bed Fusion
BibTeX
@article{slama2026electrothermal,
title = {{Electro-thermal PEMFC system modeling with experimental validation on 6 kW liquid-cooled stack}},
author = {Rafika Ben Haj Slama and Mouhamad Ankouni and Mohamed Moussa El Idi and Chaima Haouati and Maher Ben Chiekh},
journal = {Engineering Research Express},
year = {2026},
month = aug,
doi = {10.1088/2631-8695/ae9673},
url = {https://hal.science/hal-05744470v1},
note = {CC BY},
}
RIS
TY - JOUR
TI - Electro-thermal PEMFC system modeling with experimental validation on 6 kW liquid-cooled stack
AU - Rafika Ben Haj Slama
AU - Mouhamad Ankouni
AU - Mohamed Moussa El Idi
AU - Chaima Haouati
AU - Maher Ben Chiekh
PY - 2026
DA - 2026/08/14
JO - Engineering Research Express
DO - 10.1088/2631-8695/ae9673
UR - https://hal.science/hal-05744470v1
AB - This paper presents the development and experimental validation of a coupled electrochemical–thermal numerical model of a liquid-cooled Proton Exchange Membrane Fuel Cell (PEMFC) system. The model is based on a 0D/1D formulation implemented in the Matlab/Simscape environment and aims to accurately reproduce both the electrical and thermal behavior of a PEMFC stack under variable operating conditions. The proposed approach integrates the main physical phenomena governing fuel cell operation, including electrochemical reactions, mass and energy balances, and the dynamics of the reactant supply subsystems. A particular attention is given to the modeling of non-conventional loss mechanisms, such as hydrogen crossover and internal short circuits, which significantly affect stack voltage and overall system performance. To validate the proposed model, an experimental test bench was developed using a 6 kW Ballard FCgen-LCS PEMFC stack equipped with a closed-loop liquid cooling circuit. Experimental tests were conducted under steady-state and transient load conditions to characterize the electrical response and the thermal dynamics of the system. Simulation results were compared with measured data through polarization curve analysis and dynamic thermal response evaluation. The comparison demonstrates a strong agreement between simulations and experiments, confirming the ability of the model to capture both electrical performance and stack thermal behavior. The proposed model therefore provides a reliable and computationally efficient tool for PEMFC system analysis, control development, and optimization of thermal management strategies.
SN - 2631-8695
ER -